* bpo-42644: Validate values in logging.disable()
Technically make the value of manager a property that checks and convert
values assigned to it properly. This has the side effect of making
`logging.disable` also accept strings representing the various level of
warnings.
We want to validate the type of the disable attribute at assignment
time, as it is later compared to other levels when emitting warnings and
would generate a `TypeError: '>=' not supported between ....` in a
different part of the code base, which can make it difficult to track
down.
When assigned an incorrect value; it will raise a TypeError when the
wrong type, or ValueError if an invalid str.
Co-authored-by: Andrew Svetlov <andrew.svetlov@gmail.com>
(cherry picked from commit b32d8b4f9b)
Co-authored-by: Matthias Bussonnier <bussonniermatthias@gmail.com>
Fix a hang at fork in the logging module: the new private
_at_fork_reinit() method is now used to reinitialize locks at fork in
the child process.
The createLock() method is no longer used at fork.
* bpo-37742: Return the root logger when logging.getLogger('root') is called.
* Added type check guard on logger name in logging.getLogger() and refined a test.
Instead of attempting to acquire and release them all across fork
which was leading to deadlocks in some applications that had chained
their own handlers while holding multiple locks.
bpo-6721: When os.fork() was called while another thread holds a logging lock, the child process may deadlock when it tries to log. This fixes that by acquiring all logging locks before fork and releasing them afterwards.
A regression test that fails before this change is included.
Within the new unittest itself: There is a small _potential_ due to mixing of fork and a thread in the child process if the parent's thread happened to hold a non-reentrant library call lock (malloc?) when the os.fork() happens. buildbots and time will tell if this actually manifests itself in this test or not. :/ A functionality test that avoids that would be a challenge.
An alternate test that isn't trying to produce the deadlock itself but just checking that the release and acquire calls are made would be the next best alternative if so.
A check has been added in Logger.isEnabledFor() to return False when the logger is disabled. This avoids unnecessary work being done when a disabled logger is used.
This used to be the case on Python 2. Commit
212b590e11 changed the implementation for Python
3, making the `log()` method of LogAdapter call `logger._log()` directly. This
makes nested log adapters not execute their ``process()`` method. This patch
fixes the issue.
Also, now proxying `name`, too, to make `repr()` work with nested log adapters.
New tests added.
Some of the proxied methods use internal Logger state which isn't proxied,
causing failures if an adapter is applied to another adapter.
This commit fixes the issue, adds a new test for the use case.