thermal: adjust thermal shutdown threshold

Acocording to the redfin EVT thermal virus test. When skin-therm is
53 degC, the max surface temperature is only 53degC. So, adjust shutdown
 threshold to 55 degC and emergency threshold to 53 degC to improvide
the UX.

Bug: 153850974
Test: Test thermalhal shutdown by emul temp
Change-Id: Ia3813e9aa4c7848d1df0a31074534e2870f6b132
Signed-off-by: TeYuan Wang <kamewang@google.com>
This commit is contained in:
TeYuan Wang 2020-06-23 14:49:50 +08:00
parent 4468efc8e2
commit 60f2a7bd30
1 changed files with 3 additions and 3 deletions

View File

@ -204,8 +204,8 @@
41.0,
43.0,
45.0,
49.0,
53.0
51.0,
55.0
],
"HotHysteresis":[
0.0,
@ -229,7 +229,7 @@
"NAN",
"NAN",
"NAN",
"51.0",
"53.0",
"NAN"
],
"HotHysteresis":[