thermal: adjust thermal shutdown threshold
Acocording to the redfin EVT thermal virus test. When skin-therm is 53 degC, the max surface temperature is only 53degC. So, adjust shutdown threshold to 55 degC and emergency threshold to 53 degC to improvide the UX. Bug: 153850974 Test: Test thermalhal shutdown by emul temp Change-Id: Ia3813e9aa4c7848d1df0a31074534e2870f6b132 Signed-off-by: TeYuan Wang <kamewang@google.com>
This commit is contained in:
parent
4468efc8e2
commit
60f2a7bd30
|
@ -204,8 +204,8 @@
|
|||
41.0,
|
||||
43.0,
|
||||
45.0,
|
||||
49.0,
|
||||
53.0
|
||||
51.0,
|
||||
55.0
|
||||
],
|
||||
"HotHysteresis":[
|
||||
0.0,
|
||||
|
@ -229,7 +229,7 @@
|
|||
"NAN",
|
||||
"NAN",
|
||||
"NAN",
|
||||
"51.0",
|
||||
"53.0",
|
||||
"NAN"
|
||||
],
|
||||