mirror of https://gitee.com/openkylin/libvirt.git
virsh: Add iothreadadd and iothreaddel commands
https://bugzilla.redhat.com/show_bug.cgi?id=1161617 Add command to allow adding and removing IOThreads from the domain including the configuration and live domain. $ virsh iothreadadd --help NAME iothreadadd - add an IOThread to the guest domain SYNOPSIS iothreadadd <domain> <id> [--config] [--live] [--current] DESCRIPTION Add an IOThread to the guest domain. OPTIONS [--domain] <string> domain name, id or uuid [--id] <number> iothread for the new IOThread --config affect next boot --live affect running domain --current affect current domain $ virsh iothreaddel --help NAME iothreaddel - delete an IOThread from the guest domain SYNOPSIS iothreaddel <domain> <id> [--config] [--live] [--current] DESCRIPTION Delete an IOThread from the guest domain. OPTIONS [--domain] <string> domain name, id or uuid [--id] <number> iothread_id for the IOThread to delete --config affect next boot --live affect running domain --current affect current domain Assuming a running $dom with multiple IOThreads assigned and that that the $dom has disks assigned to IOThread 1 and IOThread 2: $ virsh iothreadinfo $dom IOThread ID CPU Affinity --------------------------------------------------- 1 2 2 3 3 0-1 $ virsh iothreadadd $dom 1 error: invalid argument: an IOThread is already using iothread_id '1' in iothreadpids $ virsh iothreadadd $dom 1 --config error: invalid argument: an IOThread is already using iothread_id '1' in persistent iothreadids $ virsh iothreadadd $dom 4 $ virsh iothreadinfo $dom IOThread ID CPU Affinity --------------------------------------------------- 1 2 2 3 3 0-1 4 0-3 $ virsh iothreadinfo $dom --config IOThread ID CPU Affinity --------------------------------------------------- 1 2 2 3 3 0-1 $ virsh iothreadadd $dom 4 --config $ virsh iothreadinfo $dom --config IOThread ID CPU Affinity --------------------------------------------------- 1 2 2 3 3 0-1 4 0-3 Assuming the same original configuration $ virsh iothreaddel $dom 1 error: invalid argument: cannot remove IOThread 1 since it is being used by disk 'vde' $ virsh iothreaddel $dom 3 $ virsh iothreadinfo $dom IOThread ID CPU Affinity --------------------------------------------------- 1 2 2 3 $ virsh iothreadinfo $dom --config IOThread ID CPU Affinity --------------------------------------------------- 1 2 2 3 3 0-1
This commit is contained in:
parent
a27ed6e78c
commit
1f7e811249
|
@ -6895,6 +6895,166 @@ cmdIOThreadPin(vshControl *ctl, const vshCmd *cmd)
|
|||
return ret;
|
||||
}
|
||||
|
||||
/*
|
||||
* "iothreadadd" command
|
||||
*/
|
||||
static const vshCmdInfo info_iothreadadd[] = {
|
||||
{.name = "help",
|
||||
.data = N_("add an IOThread to the guest domain")
|
||||
},
|
||||
{.name = "desc",
|
||||
.data = N_("Add an IOThread to the guest domain.")
|
||||
},
|
||||
{.name = NULL}
|
||||
};
|
||||
|
||||
static const vshCmdOptDef opts_iothreadadd[] = {
|
||||
{.name = "domain",
|
||||
.type = VSH_OT_DATA,
|
||||
.flags = VSH_OFLAG_REQ,
|
||||
.help = N_("domain name, id or uuid")
|
||||
},
|
||||
{.name = "id",
|
||||
.type = VSH_OT_INT,
|
||||
.flags = VSH_OFLAG_REQ,
|
||||
.help = N_("iothread for the new IOThread")
|
||||
},
|
||||
{.name = "config",
|
||||
.type = VSH_OT_BOOL,
|
||||
.help = N_("affect next boot")
|
||||
},
|
||||
{.name = "live",
|
||||
.type = VSH_OT_BOOL,
|
||||
.help = N_("affect running domain")
|
||||
},
|
||||
{.name = "current",
|
||||
.type = VSH_OT_BOOL,
|
||||
.help = N_("affect current domain")
|
||||
},
|
||||
{.name = NULL}
|
||||
};
|
||||
|
||||
static bool
|
||||
cmdIOThreadAdd(vshControl *ctl, const vshCmd *cmd)
|
||||
{
|
||||
virDomainPtr dom;
|
||||
int iothread_id = 0;
|
||||
bool ret = false;
|
||||
bool config = vshCommandOptBool(cmd, "config");
|
||||
bool live = vshCommandOptBool(cmd, "live");
|
||||
bool current = vshCommandOptBool(cmd, "current");
|
||||
unsigned int flags = VIR_DOMAIN_AFFECT_CURRENT;
|
||||
|
||||
VSH_EXCLUSIVE_OPTIONS_VAR(current, live);
|
||||
VSH_EXCLUSIVE_OPTIONS_VAR(current, config);
|
||||
|
||||
if (config)
|
||||
flags |= VIR_DOMAIN_AFFECT_CONFIG;
|
||||
if (live)
|
||||
flags |= VIR_DOMAIN_AFFECT_LIVE;
|
||||
|
||||
if (!(dom = vshCommandOptDomain(ctl, cmd, NULL)))
|
||||
return false;
|
||||
|
||||
if (vshCommandOptInt(cmd, "id", &iothread_id) < 0) {
|
||||
vshError(ctl, "%s", _("Unable to parse integer parameter"));
|
||||
goto cleanup;
|
||||
}
|
||||
if (iothread_id <= 0) {
|
||||
vshError(ctl, _("Invalid IOThread id value: '%d'"), iothread_id);
|
||||
goto cleanup;
|
||||
}
|
||||
|
||||
if (virDomainAddIOThread(dom, iothread_id, flags) < 0)
|
||||
goto cleanup;
|
||||
|
||||
ret = true;
|
||||
|
||||
cleanup:
|
||||
virDomainFree(dom);
|
||||
return ret;
|
||||
}
|
||||
|
||||
/*
|
||||
* "iothreaddel" command
|
||||
*/
|
||||
static const vshCmdInfo info_iothreaddel[] = {
|
||||
{.name = "help",
|
||||
.data = N_("delete an IOThread from the guest domain")
|
||||
},
|
||||
{.name = "desc",
|
||||
.data = N_("Delete an IOThread from the guest domain.")
|
||||
},
|
||||
{.name = NULL}
|
||||
};
|
||||
|
||||
static const vshCmdOptDef opts_iothreaddel[] = {
|
||||
{.name = "domain",
|
||||
.type = VSH_OT_DATA,
|
||||
.flags = VSH_OFLAG_REQ,
|
||||
.help = N_("domain name, id or uuid")
|
||||
},
|
||||
{.name = "id",
|
||||
.type = VSH_OT_INT,
|
||||
.flags = VSH_OFLAG_REQ,
|
||||
.help = N_("iothread_id for the IOThread to delete")
|
||||
},
|
||||
{.name = "config",
|
||||
.type = VSH_OT_BOOL,
|
||||
.help = N_("affect next boot")
|
||||
},
|
||||
{.name = "live",
|
||||
.type = VSH_OT_BOOL,
|
||||
.help = N_("affect running domain")
|
||||
},
|
||||
{.name = "current",
|
||||
.type = VSH_OT_BOOL,
|
||||
.help = N_("affect current domain")
|
||||
},
|
||||
{.name = NULL}
|
||||
};
|
||||
|
||||
static bool
|
||||
cmdIOThreadDel(vshControl *ctl, const vshCmd *cmd)
|
||||
{
|
||||
virDomainPtr dom;
|
||||
int iothread_id = 0;
|
||||
bool ret = false;
|
||||
bool config = vshCommandOptBool(cmd, "config");
|
||||
bool live = vshCommandOptBool(cmd, "live");
|
||||
bool current = vshCommandOptBool(cmd, "current");
|
||||
unsigned int flags = VIR_DOMAIN_AFFECT_CURRENT;
|
||||
|
||||
VSH_EXCLUSIVE_OPTIONS_VAR(current, live);
|
||||
VSH_EXCLUSIVE_OPTIONS_VAR(current, config);
|
||||
|
||||
if (config)
|
||||
flags |= VIR_DOMAIN_AFFECT_CONFIG;
|
||||
if (live)
|
||||
flags |= VIR_DOMAIN_AFFECT_LIVE;
|
||||
|
||||
if (!(dom = vshCommandOptDomain(ctl, cmd, NULL)))
|
||||
return false;
|
||||
|
||||
if (vshCommandOptInt(cmd, "id", &iothread_id) < 0) {
|
||||
vshError(ctl, "%s", _("Unable to parse integer parameter"));
|
||||
goto cleanup;
|
||||
}
|
||||
if (iothread_id <= 0) {
|
||||
vshError(ctl, _("Invalid IOThread id value: '%d'"), iothread_id);
|
||||
goto cleanup;
|
||||
}
|
||||
|
||||
if (virDomainDelIOThread(dom, iothread_id, flags) < 0)
|
||||
goto cleanup;
|
||||
|
||||
ret = true;
|
||||
|
||||
cleanup:
|
||||
virDomainFree(dom);
|
||||
return ret;
|
||||
}
|
||||
|
||||
/*
|
||||
* "cpu-compare" command
|
||||
*/
|
||||
|
@ -12845,6 +13005,18 @@ const vshCmdDef domManagementCmds[] = {
|
|||
.info = info_iothreadpin,
|
||||
.flags = 0
|
||||
},
|
||||
{.name = "iothreadadd",
|
||||
.handler = cmdIOThreadAdd,
|
||||
.opts = opts_iothreadadd,
|
||||
.info = info_iothreadadd,
|
||||
.flags = 0
|
||||
},
|
||||
{.name = "iothreaddel",
|
||||
.handler = cmdIOThreadDel,
|
||||
.opts = opts_iothreaddel,
|
||||
.info = info_iothreaddel,
|
||||
.flags = 0
|
||||
},
|
||||
{.name = "send-key",
|
||||
.handler = cmdSendKey,
|
||||
.opts = opts_send_key,
|
||||
|
|
|
@ -1416,6 +1416,33 @@ If no flag is specified, behavior is different depending on hypervisor.
|
|||
B<Note>: The expression is sequentially evaluated, so "0-15,^8" is
|
||||
identical to "9-14,0-7,15" but not identical to "^8,0-15".
|
||||
|
||||
=item B<iothreadadd> I<domain> I<iothread_id>
|
||||
[[I<--config>] [I<--live>] | [I<--current>]]
|
||||
|
||||
Add a new IOThread to the domain using the specified I<iothread_id>.
|
||||
If the I<iothread_id> already exists, the command will fail. The
|
||||
I<iothread_id> must be greater than zero.
|
||||
|
||||
If I<--live> is specified, affect a running guest. If the guest is not
|
||||
running an error is returned.
|
||||
If I<--config> is specified, affect the next boot of a persistent guest.
|
||||
If I<--current> is specified or I<--live> and I<--config> are not specified,
|
||||
affect the current guest state.
|
||||
|
||||
=item B<iothreaddel> I<domain> I<iothread_id>
|
||||
[[I<--config>] [I<--live>] | [I<--current>]]
|
||||
|
||||
Delete an IOThread from the domain using the specified I<iothread_id>.
|
||||
If an IOThread is currently assigned to a disk resource such as via the
|
||||
B<attach-disk> command, then the attempt to remove the IOThread will fail.
|
||||
If the I<iothread_id> does not exist an error will occur.
|
||||
|
||||
If I<--live> is specified, affect a running guest. If the guest is not
|
||||
running an error is returned.
|
||||
If I<--config> is specified, affect the next boot of a persistent guest.
|
||||
If I<--current> is specified or I<--live> and I<--config> are not specified,
|
||||
affect the current guest state.
|
||||
|
||||
=item B<managedsave> I<domain> [I<--bypass-cache>]
|
||||
[{I<--running> | I<--paused>}] [I<--verbose>]
|
||||
|
||||
|
|
Loading…
Reference in New Issue