mirror of https://gitee.com/openkylin/libvirt.git
Enable the blkdeviotune command in virsh
Support virsh command blkdeviotune. Can set or query a block disk I/O throttle setting. Signed-off-by: Lei Li <lilei@linux.vnet.ibm.com> Signed-off-by: Zhi Yong Wu <wuzhy@linux.vnet.ibm.com> Signed-off-by: Eric Blake <eblake@redhat.com>
This commit is contained in:
parent
eca96694a7
commit
e9bd9a0809
244
tools/virsh.c
244
tools/virsh.c
|
@ -6225,6 +6225,249 @@ cmdNetworkAutostart(vshControl *ctl, const vshCmd *cmd)
|
|||
return true;
|
||||
}
|
||||
|
||||
/*
|
||||
* "blkdeviotune" command
|
||||
*/
|
||||
static const vshCmdInfo info_blkdeviotune[] = {
|
||||
{"help", N_("Set or query a block device I/O tuning parameters.")},
|
||||
{"desc", N_("Set or query disk I/O parameters such as block throttling.")},
|
||||
{NULL, NULL}
|
||||
};
|
||||
|
||||
static const vshCmdOptDef opts_blkdeviotune[] = {
|
||||
{"domain", VSH_OT_DATA, VSH_OFLAG_REQ, N_("domain name, id or uuid")},
|
||||
{"device", VSH_OT_DATA, VSH_OFLAG_REQ, N_("block device")},
|
||||
{"total_bytes_sec", VSH_OT_INT, VSH_OFLAG_NONE,
|
||||
N_("total throughput limit in bytes per second")},
|
||||
{"read_bytes_sec", VSH_OT_INT, VSH_OFLAG_NONE,
|
||||
N_("read throughput limit in bytes per second")},
|
||||
{"write_bytes_sec", VSH_OT_INT, VSH_OFLAG_NONE,
|
||||
N_("write throughput limit in bytes per second")},
|
||||
{"total_iops_sec", VSH_OT_INT, VSH_OFLAG_NONE,
|
||||
N_("total I/O operations limit per second")},
|
||||
{"read_iops_sec", VSH_OT_INT, VSH_OFLAG_NONE,
|
||||
N_("read I/O operations limit per second")},
|
||||
{"write_iops_sec", VSH_OT_INT, VSH_OFLAG_NONE,
|
||||
N_("write I/O operations limit per second")},
|
||||
{"config", VSH_OT_BOOL, 0, N_("affect next boot")},
|
||||
{"live", VSH_OT_BOOL, 0, N_("affect running domain")},
|
||||
{"current", VSH_OT_BOOL, 0, N_("affect current domain")},
|
||||
{NULL, 0, 0, NULL}
|
||||
};
|
||||
|
||||
static bool
|
||||
cmdBlkdeviotune(vshControl *ctl, const vshCmd *cmd)
|
||||
{
|
||||
virDomainPtr dom = NULL;
|
||||
const char *name, *disk;
|
||||
unsigned long long total_bytes_sec = 0, read_bytes_sec = 0, write_bytes_sec = 0;
|
||||
unsigned long long total_iops_sec = 0, read_iops_sec = 0, write_iops_sec = 0;
|
||||
int nparams = 0;
|
||||
virTypedParameterPtr params = NULL, temp = NULL;
|
||||
unsigned int flags = 0, i = 0;
|
||||
int rv = 0;
|
||||
int current = vshCommandOptBool(cmd, "current");
|
||||
int config = vshCommandOptBool(cmd, "config");
|
||||
int live = vshCommandOptBool(cmd, "live");
|
||||
bool ret = false;
|
||||
|
||||
if (current) {
|
||||
if (live || config) {
|
||||
vshError(ctl, "%s", _("--current must be specified exclusively"));
|
||||
return false;
|
||||
}
|
||||
flags = VIR_DOMAIN_AFFECT_CURRENT;
|
||||
} else {
|
||||
if (config)
|
||||
flags |= VIR_DOMAIN_AFFECT_CONFIG;
|
||||
if (live)
|
||||
flags |= VIR_DOMAIN_AFFECT_LIVE;
|
||||
}
|
||||
|
||||
if (!vshConnectionUsability(ctl, ctl->conn))
|
||||
goto cleanup;
|
||||
|
||||
if (!(dom = vshCommandOptDomain(ctl, cmd, &name)))
|
||||
goto cleanup;
|
||||
|
||||
if (vshCommandOptString(cmd, "device", &disk) < 0)
|
||||
goto cleanup;
|
||||
|
||||
if ((rv = vshCommandOptULongLong(cmd, "total_bytes_sec", &total_bytes_sec)) < 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to parse integer parameter"));
|
||||
goto cleanup;
|
||||
} else if (rv > 0) {
|
||||
nparams++;
|
||||
}
|
||||
|
||||
if ((rv = vshCommandOptULongLong(cmd, "read_bytes_sec", &read_bytes_sec)) < 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to parse integer parameter"));
|
||||
goto cleanup;
|
||||
} else if (rv > 0) {
|
||||
nparams++;
|
||||
}
|
||||
|
||||
if ((rv = vshCommandOptULongLong(cmd, "write_bytes_sec", &write_bytes_sec)) < 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to parse integer parameter"));
|
||||
goto cleanup;
|
||||
} else if (rv > 0) {
|
||||
nparams++;
|
||||
}
|
||||
|
||||
if ((rv = vshCommandOptULongLong(cmd, "total_iops_sec", &total_iops_sec)) < 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to parse integer parameter"));
|
||||
goto cleanup;
|
||||
} else if (rv > 0) {
|
||||
nparams++;
|
||||
}
|
||||
|
||||
if ((rv = vshCommandOptULongLong(cmd, "read_iops_sec", &read_iops_sec)) < 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to parse integer parameter"));
|
||||
goto cleanup;
|
||||
} else if (rv > 0) {
|
||||
nparams++;
|
||||
}
|
||||
|
||||
if ((rv = vshCommandOptULongLong(cmd, "write_iops_sec", &write_iops_sec)) < 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to parse integer parameter"));
|
||||
goto cleanup;
|
||||
} else if (rv > 0) {
|
||||
nparams++;
|
||||
}
|
||||
|
||||
if (nparams == 0) {
|
||||
|
||||
if ((virDomainGetBlockIoTune(dom, NULL, NULL, &nparams, flags)) != 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to get number of block I/O throttle parameters"));
|
||||
goto cleanup;
|
||||
}
|
||||
|
||||
if (nparams == 0) {
|
||||
ret = true;
|
||||
goto cleanup;
|
||||
}
|
||||
|
||||
params = vshCalloc(ctl, nparams, sizeof(*params));
|
||||
|
||||
if ((virDomainGetBlockIoTune(dom, disk, params, &nparams, flags)) != 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to get block I/O throttle parameters"));
|
||||
goto cleanup;
|
||||
}
|
||||
|
||||
for (i = 0; i < nparams; i++) {
|
||||
switch(params[i].type) {
|
||||
case VIR_TYPED_PARAM_INT:
|
||||
vshPrint(ctl, "%-15s: %d\n", params[i].field,
|
||||
params[i].value.i);
|
||||
break;
|
||||
case VIR_TYPED_PARAM_UINT:
|
||||
vshPrint(ctl, "%-15s: %u\n", params[i].field,
|
||||
params[i].value.ui);
|
||||
break;
|
||||
case VIR_TYPED_PARAM_LLONG:
|
||||
vshPrint(ctl, "%-15s: %lld\n", params[i].field,
|
||||
params[i].value.l);
|
||||
break;
|
||||
case VIR_TYPED_PARAM_ULLONG:
|
||||
vshPrint(ctl, "%-15s: %llu\n", params[i].field,
|
||||
params[i].value.ul);
|
||||
break;
|
||||
case VIR_TYPED_PARAM_DOUBLE:
|
||||
vshPrint(ctl, "%-15s: %f\n", params[i].field,
|
||||
params[i].value.d);
|
||||
break;
|
||||
case VIR_TYPED_PARAM_BOOLEAN:
|
||||
vshPrint(ctl, "%-15s: %d\n", params[i].field,
|
||||
params[i].value.b);
|
||||
break;
|
||||
default:
|
||||
vshPrint(ctl, "unimplemented block I/O throttle parameter type\n");
|
||||
}
|
||||
}
|
||||
|
||||
virDomainFree(dom);
|
||||
return true;
|
||||
} else {
|
||||
/* Set the block I/O throttle, match by opt since parameters can be 0 */
|
||||
params = vshCalloc(ctl, nparams, sizeof(*params));
|
||||
i = 0;
|
||||
|
||||
if ((i < nparams) && (vshCommandOptBool(cmd, "total_bytes_sec"))) {
|
||||
temp = ¶ms[i];
|
||||
temp->type = VIR_TYPED_PARAM_ULLONG;
|
||||
strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_TOTAL_BYTES_SEC,
|
||||
sizeof(temp->field));
|
||||
temp->value.ul = total_bytes_sec;
|
||||
i++;
|
||||
}
|
||||
|
||||
if ((i < nparams) && (vshCommandOptBool(cmd, "read_bytes_sec"))) {
|
||||
temp = ¶ms[i];
|
||||
temp->type = VIR_TYPED_PARAM_ULLONG;
|
||||
strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_READ_BYTES_SEC,
|
||||
sizeof(temp->field));
|
||||
temp->value.ul = read_bytes_sec;
|
||||
i++;
|
||||
}
|
||||
|
||||
if ((i < nparams) && (vshCommandOptBool(cmd, "write_bytes_sec"))) {
|
||||
temp = ¶ms[i];
|
||||
temp->type = VIR_TYPED_PARAM_ULLONG;
|
||||
strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_WRITE_BYTES_SEC,
|
||||
sizeof(temp->field));
|
||||
temp->value.ul = write_bytes_sec;
|
||||
i++;
|
||||
}
|
||||
|
||||
if ((i < nparams) && (vshCommandOptBool(cmd, "total_iops_sec"))) {
|
||||
temp = ¶ms[i];
|
||||
temp->type = VIR_TYPED_PARAM_ULLONG;
|
||||
strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_TOTAL_IOPS_SEC,
|
||||
sizeof(temp->field));
|
||||
temp->value.ul = total_iops_sec;
|
||||
i++;
|
||||
}
|
||||
|
||||
if ((i < nparams) && (vshCommandOptBool(cmd, "read_iops_sec"))) {
|
||||
temp = ¶ms[i];
|
||||
temp->type = VIR_TYPED_PARAM_ULLONG;
|
||||
strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_READ_IOPS_SEC,
|
||||
sizeof(temp->field));
|
||||
temp->value.ul = read_iops_sec;
|
||||
i++;
|
||||
}
|
||||
|
||||
if ((i < nparams) && (vshCommandOptBool(cmd, "write_iops_sec"))) {
|
||||
temp = ¶ms[i];
|
||||
temp->type = VIR_TYPED_PARAM_ULLONG;
|
||||
strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_WRITE_IOPS_SEC,
|
||||
sizeof(temp->field));
|
||||
temp->value.ul = write_iops_sec;
|
||||
}
|
||||
|
||||
if ((virDomainSetBlockIoTune(dom, disk, params, nparams, flags)) < 0) {
|
||||
vshError(ctl, "%s",
|
||||
_("Unable to change block I/O throttle"));
|
||||
goto cleanup;
|
||||
}
|
||||
}
|
||||
|
||||
ret = true;
|
||||
|
||||
cleanup:
|
||||
VIR_FREE(params);
|
||||
virDomainFree(dom);
|
||||
return ret;
|
||||
}
|
||||
|
||||
/*
|
||||
* "net-create" command
|
||||
*/
|
||||
|
@ -14842,6 +15085,7 @@ static const vshCmdDef domManagementCmds[] = {
|
|||
{"attach-interface", cmdAttachInterface, opts_attach_interface,
|
||||
info_attach_interface, 0},
|
||||
{"autostart", cmdAutostart, opts_autostart, info_autostart, 0},
|
||||
{"blkdeviotune", cmdBlkdeviotune, opts_blkdeviotune, info_blkdeviotune, 0},
|
||||
{"blkiotune", cmdBlkiotune, opts_blkiotune, info_blkiotune, 0},
|
||||
{"blockpull", cmdBlockPull, opts_block_pull, info_block_pull, 0},
|
||||
{"blockjob", cmdBlockJob, opts_block_job, info_block_job, 0},
|
||||
|
|
|
@ -579,6 +579,36 @@ operation can be checked with B<blockjob>.
|
|||
I<path> specifies fully-qualified path of the disk.
|
||||
I<bandwidth> specifies copying bandwidth limit in Mbps.
|
||||
|
||||
=item B<blkdeviotune> I<domain> I<device>
|
||||
[[I<--config>] [I<--live>] | [I<--current>]]
|
||||
[[I<total_bytes_sec>] | [I<read_bytes_sec>] [I<write_bytes_sec>]]
|
||||
[[I<total_iops_sec>] | [I<read_iops_sec>] [I<write_iops_sec>]]
|
||||
|
||||
Set or query the block disk io parameters for a block device of I<domain>.
|
||||
I<device> specifies a unique target name (<target dev='name'/>) or source
|
||||
file (<source file='name'/>) for one of the disk devices attached to
|
||||
I<domain> (see also B<domblklist> for listing these names).
|
||||
|
||||
If no limit is specified, it will query current I/O limits setting.
|
||||
Otherwise, alter the limits with these flags:
|
||||
I<--total_bytes_sec> specifies total throughput limit in bytes per second.
|
||||
I<--read_bytes_sec> specifies read throughput limit in bytes per second.
|
||||
I<--write_bytes_sec> specifies write throughput limit in bytes per second.
|
||||
I<--total_iops_sec> specifies total I/O operations limit per second.
|
||||
I<--read_iops_sec> specifies read I/O operations limit per second.
|
||||
I<--write_iops_sec> specifies write I/O operations limit per second.
|
||||
|
||||
When setting any value, all remaining values are reset to unlimited,
|
||||
an explicit 0 also clears any limit. A non-zero value for a given total
|
||||
cannot be mixed with non-zero values for read or write.
|
||||
|
||||
If I<--live> is specified, affect a running guest.
|
||||
If I<--config> is specified, affect the next boot of a persistent guest.
|
||||
If I<--current> is specified, affect the current guest state.
|
||||
Both I<--live> and I<--current> flags may be given, but I<--current> is
|
||||
exclusive. If no flag is specified, behavior is different depending
|
||||
on hypervisor.
|
||||
|
||||
=item B<blockjob> I<domain> I<path> [I<--abort>] [I<--info>] [I<bandwidth>]
|
||||
|
||||
Manage active block operations.
|
||||
|
|
Loading…