libvirt/tools/virsh-pool.c

2245 lines
65 KiB
C

/*
* virsh-pool.c: Commands to manage storage pool
*
* Copyright (C) 2005, 2007-2016 Red Hat, Inc.
*
* This library is free software; you can redistribute it and/or
* modify it under the terms of the GNU Lesser General Public
* License as published by the Free Software Foundation; either
* version 2.1 of the License, or (at your option) any later version.
*
* This library is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* Lesser General Public License for more details.
*
* You should have received a copy of the GNU Lesser General Public
* License along with this library. If not, see
* <http://www.gnu.org/licenses/>.
*/
#include <config.h>
#include "virsh-pool.h"
#include "virsh-util.h"
#include "internal.h"
#include "virbuffer.h"
#include "viralloc.h"
#include "virfile.h"
#include "conf/storage_conf.h"
#include "virtime.h"
#include "vsh-table.h"
#include "virenum.h"
#define VIRSH_COMMON_OPT_POOL_FULL(cflags) \
VIRSH_COMMON_OPT_POOL(N_("pool name or uuid"), cflags)
#define VIRSH_COMMON_OPT_POOL_BUILD \
{.name = "build", \
.type = VSH_OT_BOOL, \
.flags = 0, \
.help = N_("build the pool as normal") \
}
#define VIRSH_COMMON_OPT_POOL_NO_OVERWRITE \
{.name = "no-overwrite", \
.type = VSH_OT_BOOL, \
.flags = 0, \
.help = N_("do not overwrite any existing data") \
}
#define VIRSH_COMMON_OPT_POOL_OVERWRITE \
{.name = "overwrite", \
.type = VSH_OT_BOOL, \
.flags = 0, \
.help = N_("overwrite any existing data") \
}
#define VIRSH_COMMON_OPT_POOL_X_AS \
{.name = "name", \
.type = VSH_OT_DATA, \
.flags = VSH_OFLAG_REQ, \
.completer = virshCompleteEmpty, \
.help = N_("name of the pool") \
}, \
{.name = "type", \
.type = VSH_OT_DATA, \
.flags = VSH_OFLAG_REQ, \
.completer = virshPoolTypeCompleter, \
.help = N_("type of the pool") \
}, \
{.name = "print-xml", \
.type = VSH_OT_BOOL, \
.help = N_("print XML document, but don't define/create") \
}, \
{.name = "source-host", \
.type = VSH_OT_STRING, \
.completer = virshCompleteEmpty, \
.help = N_("source-host for underlying storage") \
}, \
{.name = "source-path", \
.type = VSH_OT_STRING, \
.help = N_("source path for underlying storage") \
}, \
{.name = "source-dev", \
.type = VSH_OT_STRING, \
.help = N_("source device for underlying storage") \
}, \
{.name = "source-name", \
.type = VSH_OT_STRING, \
.help = N_("source name for underlying storage") \
}, \
{.name = "target", \
.type = VSH_OT_STRING, \
.help = N_("target for underlying storage") \
}, \
{.name = "source-format", \
.type = VSH_OT_STRING, \
.help = N_("format for underlying storage") \
}, \
{.name = "auth-type", \
.type = VSH_OT_STRING, \
.help = N_("auth type to be used for underlying storage") \
}, \
{.name = "auth-username", \
.type = VSH_OT_STRING, \
.completer = virshCompleteEmpty, \
.help = N_("auth username to be used for underlying storage") \
}, \
{.name = "secret-usage", \
.type = VSH_OT_STRING, \
.help = N_("auth secret usage to be used for underlying storage") \
}, \
{.name = "secret-uuid", \
.type = VSH_OT_STRING, \
.help = N_("auth secret UUID to be used for underlying storage") \
}, \
{.name = "adapter-name", \
.type = VSH_OT_STRING, \
.help = N_("adapter name to be used for underlying storage") \
}, \
{.name = "adapter-wwnn", \
.type = VSH_OT_STRING, \
.help = N_("adapter wwnn to be used for underlying storage") \
}, \
{.name = "adapter-wwpn", \
.type = VSH_OT_STRING, \
.help = N_("adapter wwpn to be used for underlying storage") \
}, \
{.name = "adapter-parent", \
.type = VSH_OT_STRING, \
.help = N_("adapter parent scsi_hostN to be used for underlying vHBA storage") \
}, \
{.name = "adapter-parent-wwnn", \
.type = VSH_OT_STRING, \
.help = N_("adapter parent scsi_hostN wwnn to be used for underlying vHBA storage") \
}, \
{.name = "adapter-parent-wwpn", \
.type = VSH_OT_STRING, \
.help = N_("adapter parent scsi_hostN wwpn to be used for underlying vHBA storage") \
}, \
{.name = "adapter-parent-fabric-wwn", \
.type = VSH_OT_STRING, \
.help = N_("adapter parent scsi_hostN fabric_wwn to be used for underlying vHBA storage") \
}, \
{.name = "source-protocol-ver", \
.type = VSH_OT_STRING, \
.help = N_("nfsvers value for NFS pool mount option") \
}, \
{.name = "source-initiator", \
.type = VSH_OT_STRING, \
.completer = virshCompleteEmpty, \
.help = N_("initiator iqn for underlying storage") \
}
virStoragePoolPtr
virshCommandOptPoolBy(vshControl *ctl, const vshCmd *cmd, const char *optname,
const char **name, unsigned int flags)
{
virStoragePoolPtr pool = NULL;
const char *n = NULL;
virshControl *priv = ctl->privData;
virCheckFlags(VIRSH_BYUUID | VIRSH_BYNAME, NULL);
if (vshCommandOptStringReq(ctl, cmd, optname, &n) < 0)
return NULL;
if (cmd->skipChecks && !n)
return NULL;
vshDebug(ctl, VSH_ERR_INFO, "%s: found option <%s>: %s\n",
cmd->def->name, optname, n);
if (name)
*name = n;
/* try it by UUID */
if ((flags & VIRSH_BYUUID) && strlen(n) == VIR_UUID_STRING_BUFLEN-1) {
vshDebug(ctl, VSH_ERR_DEBUG, "%s: <%s> trying as pool UUID\n",
cmd->def->name, optname);
pool = virStoragePoolLookupByUUIDString(priv->conn, n);
}
/* try it by NAME */
if (!pool && (flags & VIRSH_BYNAME)) {
vshDebug(ctl, VSH_ERR_DEBUG, "%s: <%s> trying as pool NAME\n",
cmd->def->name, optname);
pool = virStoragePoolLookupByName(priv->conn, n);
}
if (!pool)
vshError(ctl, _("failed to get pool '%s'"), n);
return pool;
}
/*
* "pool-autostart" command
*/
static const vshCmdInfo info_pool_autostart[] = {
{.name = "help",
.data = N_("autostart a pool")
},
{.name = "desc",
.data = N_("Configure a pool to be automatically started at boot.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_autostart[] = {
VIRSH_COMMON_OPT_POOL_FULL(VIR_CONNECT_LIST_STORAGE_POOLS_PERSISTENT),
{.name = "disable",
.type = VSH_OT_BOOL,
.help = N_("disable autostarting")
},
{.name = NULL}
};
static bool
cmdPoolAutostart(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
const char *name;
int autostart;
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", &name)))
return false;
autostart = !vshCommandOptBool(cmd, "disable");
if (virStoragePoolSetAutostart(pool, autostart) < 0) {
if (autostart)
vshError(ctl, _("failed to mark pool %s as autostarted"), name);
else
vshError(ctl, _("failed to unmark pool %s as autostarted"), name);
return false;
}
if (autostart)
vshPrintExtra(ctl, _("Pool %s marked as autostarted\n"), name);
else
vshPrintExtra(ctl, _("Pool %s unmarked as autostarted\n"), name);
return true;
}
/*
* "pool-create" command
*/
static const vshCmdInfo info_pool_create[] = {
{.name = "help",
.data = N_("create a pool from an XML file")
},
{.name = "desc",
.data = N_("Create a pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_create[] = {
VIRSH_COMMON_OPT_FILE(N_("file containing an XML pool description")),
VIRSH_COMMON_OPT_POOL_BUILD,
VIRSH_COMMON_OPT_POOL_NO_OVERWRITE,
VIRSH_COMMON_OPT_POOL_OVERWRITE,
{.name = NULL}
};
static bool
cmdPoolCreate(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
const char *from = NULL;
g_autofree char *buffer = NULL;
bool build;
bool overwrite;
bool no_overwrite;
unsigned int flags = 0;
virshControl *priv = ctl->privData;
if (vshCommandOptStringReq(ctl, cmd, "file", &from) < 0)
return false;
build = vshCommandOptBool(cmd, "build");
overwrite = vshCommandOptBool(cmd, "overwrite");
no_overwrite = vshCommandOptBool(cmd, "no-overwrite");
VSH_EXCLUSIVE_OPTIONS_EXPR("overwrite", overwrite,
"no-overwrite", no_overwrite);
if (build)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD;
if (overwrite)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD_OVERWRITE;
if (no_overwrite)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD_NO_OVERWRITE;
if (virFileReadAll(from, VSH_MAX_XML_FILE, &buffer) < 0)
return false;
if (!(pool = virStoragePoolCreateXML(priv->conn, buffer, flags))) {
vshError(ctl, _("Failed to create pool from %s"), from);
return false;
}
vshPrintExtra(ctl, _("Pool %s created from %s\n"),
virStoragePoolGetName(pool), from);
return true;
}
static const vshCmdOptDef opts_pool_define_as[] = {
VIRSH_COMMON_OPT_POOL_X_AS,
{.name = NULL}
};
static int
virshBuildPoolXML(vshControl *ctl,
const vshCmd *cmd,
const char **retname,
char **xml)
{
const char *name = NULL, *type = NULL, *srcHost = NULL, *srcPath = NULL,
*srcDev = NULL, *srcName = NULL, *srcFormat = NULL,
*target = NULL, *authType = NULL, *authUsername = NULL,
*secretUsage = NULL, *adapterName = NULL, *adapterParent = NULL,
*adapterWwnn = NULL, *adapterWwpn = NULL, *secretUUID = NULL,
*adapterParentWwnn = NULL, *adapterParentWwpn = NULL,
*adapterParentFabricWwn = NULL, *protoVer = NULL,
*srcInitiator = NULL;
g_auto(virBuffer) buf = VIR_BUFFER_INITIALIZER;
VSH_EXCLUSIVE_OPTIONS("secret-usage", "secret-uuid");
if (vshCommandOptStringReq(ctl, cmd, "name", &name) < 0)
return false;
if (vshCommandOptStringReq(ctl, cmd, "type", &type) < 0)
return false;
if (vshCommandOptStringReq(ctl, cmd, "source-host", &srcHost) < 0 ||
vshCommandOptStringReq(ctl, cmd, "source-path", &srcPath) < 0 ||
vshCommandOptStringReq(ctl, cmd, "source-dev", &srcDev) < 0 ||
vshCommandOptStringReq(ctl, cmd, "source-name", &srcName) < 0 ||
vshCommandOptStringReq(ctl, cmd, "source-format", &srcFormat) < 0 ||
vshCommandOptStringReq(ctl, cmd, "target", &target) < 0 ||
vshCommandOptStringReq(ctl, cmd, "auth-type", &authType) < 0 ||
vshCommandOptStringReq(ctl, cmd, "auth-username", &authUsername) < 0 ||
vshCommandOptStringReq(ctl, cmd, "secret-usage", &secretUsage) < 0 ||
vshCommandOptStringReq(ctl, cmd, "secret-uuid", &secretUUID) < 0 ||
vshCommandOptStringReq(ctl, cmd, "adapter-name", &adapterName) < 0 ||
vshCommandOptStringReq(ctl, cmd, "adapter-wwnn", &adapterWwnn) < 0 ||
vshCommandOptStringReq(ctl, cmd, "adapter-wwpn", &adapterWwpn) < 0 ||
vshCommandOptStringReq(ctl, cmd, "adapter-parent", &adapterParent) < 0 ||
vshCommandOptStringReq(ctl, cmd, "adapter-parent-wwnn", &adapterParentWwnn) < 0 ||
vshCommandOptStringReq(ctl, cmd, "adapter-parent-wwpn", &adapterParentWwpn) < 0 ||
vshCommandOptStringReq(ctl, cmd, "adapter-parent-fabric-wwn", &adapterParentFabricWwn) < 0 ||
vshCommandOptStringReq(ctl, cmd, "source-protocol-ver", &protoVer) < 0 ||
vshCommandOptStringReq(ctl, cmd, "source-initiator", &srcInitiator) < 0) {
return false;
}
virBufferAsprintf(&buf, "<pool type='%s'>\n", type);
virBufferAdjustIndent(&buf, 2);
virBufferAsprintf(&buf, "<name>%s</name>\n", name);
if (srcHost || srcPath || srcDev || srcInitiator || srcFormat ||
srcName || (adapterWwnn && adapterWwpn) || adapterName) {
virBufferAddLit(&buf, "<source>\n");
virBufferAdjustIndent(&buf, 2);
if (srcHost)
virBufferAsprintf(&buf, "<host name='%s'/>\n", srcHost);
if (srcPath)
virBufferAsprintf(&buf, "<dir path='%s'/>\n", srcPath);
if (srcDev)
virBufferAsprintf(&buf, "<device path='%s'/>\n", srcDev);
if (srcInitiator) {
virBufferAddLit(&buf, "<initiator>\n");
virBufferAdjustIndent(&buf, 2);
virBufferAsprintf(&buf, "<iqn name='%s'/>\n", srcInitiator);
virBufferAdjustIndent(&buf, -2);
virBufferAddLit(&buf, "</initiator>\n");
}
if (adapterWwnn && adapterWwpn) {
virBufferAddLit(&buf, "<adapter type='fc_host'");
if (adapterParent)
virBufferAsprintf(&buf, " parent='%s'", adapterParent);
else if (adapterParentWwnn && adapterParentWwpn)
virBufferAsprintf(&buf, " parent_wwnn='%s' parent_wwpn='%s'",
adapterParentWwnn, adapterParentWwpn);
else if (adapterParentFabricWwn)
virBufferAsprintf(&buf, " parent_fabric_wwn='%s'",
adapterParentFabricWwn);
virBufferAsprintf(&buf, " wwnn='%s' wwpn='%s'/>\n",
adapterWwnn, adapterWwpn);
} else if (adapterName) {
virBufferAsprintf(&buf, "<adapter type='scsi_host' name='%s'/>\n",
adapterName);
}
if (authType && authUsername && (secretUsage || secretUUID)) {
virBufferAsprintf(&buf, "<auth type='%s' username='%s'>\n",
authType, authUsername);
virBufferAdjustIndent(&buf, 2);
if (secretUsage)
virBufferAsprintf(&buf, "<secret usage='%s'/>\n", secretUsage);
else
virBufferAsprintf(&buf, "<secret uuid='%s'/>\n", secretUUID);
virBufferAdjustIndent(&buf, -2);
virBufferAddLit(&buf, "</auth>\n");
}
if (srcFormat)
virBufferAsprintf(&buf, "<format type='%s'/>\n", srcFormat);
if (srcName)
virBufferAsprintf(&buf, "<name>%s</name>\n", srcName);
if (protoVer)
virBufferAsprintf(&buf, "<protocol ver='%s'/>\n", protoVer);
virBufferAdjustIndent(&buf, -2);
virBufferAddLit(&buf, "</source>\n");
}
if (target) {
virBufferAddLit(&buf, "<target>\n");
virBufferAdjustIndent(&buf, 2);
virBufferAsprintf(&buf, "<path>%s</path>\n", target);
virBufferAdjustIndent(&buf, -2);
virBufferAddLit(&buf, "</target>\n");
}
virBufferAdjustIndent(&buf, -2);
virBufferAddLit(&buf, "</pool>\n");
*xml = virBufferContentAndReset(&buf);
*retname = name;
return true;
}
/*
* "pool-create-as" command
*/
static const vshCmdInfo info_pool_create_as[] = {
{.name = "help",
.data = N_("create a pool from a set of args")
},
{.name = "desc",
.data = N_("Create a pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_create_as[] = {
VIRSH_COMMON_OPT_POOL_X_AS,
VIRSH_COMMON_OPT_POOL_BUILD,
VIRSH_COMMON_OPT_POOL_NO_OVERWRITE,
VIRSH_COMMON_OPT_POOL_OVERWRITE,
{.name = NULL}
};
static bool
cmdPoolCreateAs(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
const char *name;
g_autofree char *xml = NULL;
bool printXML = vshCommandOptBool(cmd, "print-xml");
bool build;
bool overwrite;
bool no_overwrite;
unsigned int flags = 0;
virshControl *priv = ctl->privData;
build = vshCommandOptBool(cmd, "build");
overwrite = vshCommandOptBool(cmd, "overwrite");
no_overwrite = vshCommandOptBool(cmd, "no-overwrite");
VSH_EXCLUSIVE_OPTIONS_EXPR("overwrite", overwrite,
"no-overwrite", no_overwrite);
if (build)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD;
if (overwrite)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD_OVERWRITE;
if (no_overwrite)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD_NO_OVERWRITE;
if (!virshBuildPoolXML(ctl, cmd, &name, &xml))
return false;
if (printXML) {
vshPrint(ctl, "%s", xml);
return true;
}
if (!(pool = virStoragePoolCreateXML(priv->conn, xml, flags))) {
vshError(ctl, _("Failed to create pool %s"), name);
return false;
}
vshPrintExtra(ctl, _("Pool %s created\n"), name);
return true;
}
/*
* "pool-define" command
*/
static const vshCmdInfo info_pool_define[] = {
{.name = "help",
.data = N_("define an inactive persistent storage pool or modify "
"an existing persistent one from an XML file")
},
{.name = "desc",
.data = N_("Define or modify a persistent storage pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_define[] = {
VIRSH_COMMON_OPT_FILE(N_("file containing an XML pool description")),
{.name = "validate",
.type = VSH_OT_BOOL,
.help = N_("validate the XML against the schema")
},
{.name = NULL}
};
static bool
cmdPoolDefine(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
const char *from = NULL;
g_autofree char *buffer = NULL;
unsigned int flags = 0;
virshControl *priv = ctl->privData;
if (vshCommandOptStringReq(ctl, cmd, "file", &from) < 0)
return false;
if (vshCommandOptBool(cmd, "validate"))
flags |= VIR_STORAGE_POOL_DEFINE_VALIDATE;
if (virFileReadAll(from, VSH_MAX_XML_FILE, &buffer) < 0)
return false;
if (!(pool = virStoragePoolDefineXML(priv->conn, buffer, flags))) {
vshError(ctl, _("Failed to define pool from %s"), from);
return false;
}
vshPrintExtra(ctl, _("Pool %s defined from %s\n"),
virStoragePoolGetName(pool), from);
return true;
}
/*
* "pool-define-as" command
*/
static const vshCmdInfo info_pool_define_as[] = {
{.name = "help",
.data = N_("define a pool from a set of args")
},
{.name = "desc",
.data = N_("Define a pool.")
},
{.name = NULL}
};
static bool
cmdPoolDefineAs(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
const char *name;
g_autofree char *xml = NULL;
bool printXML = vshCommandOptBool(cmd, "print-xml");
virshControl *priv = ctl->privData;
if (!virshBuildPoolXML(ctl, cmd, &name, &xml))
return false;
if (printXML) {
vshPrint(ctl, "%s", xml);
return true;
}
if (!(pool = virStoragePoolDefineXML(priv->conn, xml, 0))) {
vshError(ctl, _("Failed to define pool %s"), name);
return false;
}
vshPrintExtra(ctl, _("Pool %s defined\n"), name);
return true;
}
/*
* "pool-build" command
*/
static const vshCmdInfo info_pool_build[] = {
{.name = "help",
.data = N_("build a pool")
},
{.name = "desc",
.data = N_("Build a given pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_build[] = {
VIRSH_COMMON_OPT_POOL_FULL(0),
VIRSH_COMMON_OPT_POOL_NO_OVERWRITE,
VIRSH_COMMON_OPT_POOL_OVERWRITE,
{.name = NULL}
};
static bool
cmdPoolBuild(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
bool ret = true;
const char *name;
unsigned int flags = 0;
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", &name)))
return false;
if (vshCommandOptBool(cmd, "no-overwrite"))
flags |= VIR_STORAGE_POOL_BUILD_NO_OVERWRITE;
if (vshCommandOptBool(cmd, "overwrite"))
flags |= VIR_STORAGE_POOL_BUILD_OVERWRITE;
if (virStoragePoolBuild(pool, flags) == 0) {
vshPrintExtra(ctl, _("Pool %s built\n"), name);
} else {
vshError(ctl, _("Failed to build pool %s"), name);
ret = false;
}
return ret;
}
/*
* "pool-destroy" command
*/
static const vshCmdInfo info_pool_destroy[] = {
{.name = "help",
.data = N_("destroy (stop) a pool")
},
{.name = "desc",
.data = N_("Forcefully stop a given pool. Raw data in the pool is untouched")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_destroy[] = {
VIRSH_COMMON_OPT_POOL_FULL(VIR_CONNECT_LIST_STORAGE_POOLS_ACTIVE),
{.name = NULL}
};
static bool
cmdPoolDestroy(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
bool ret = true;
const char *name;
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", &name)))
return false;
if (virStoragePoolDestroy(pool) == 0) {
vshPrintExtra(ctl, _("Pool %s destroyed\n"), name);
} else {
vshError(ctl, _("Failed to destroy pool %s"), name);
ret = false;
}
return ret;
}
/*
* "pool-delete" command
*/
static const vshCmdInfo info_pool_delete[] = {
{.name = "help",
.data = N_("delete a pool")
},
{.name = "desc",
.data = N_("Delete a given pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_delete[] = {
VIRSH_COMMON_OPT_POOL_FULL(VIR_CONNECT_LIST_STORAGE_POOLS_INACTIVE),
{.name = NULL}
};
static bool
cmdPoolDelete(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
bool ret = true;
const char *name;
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", &name)))
return false;
if (virStoragePoolDelete(pool, 0) == 0) {
vshPrintExtra(ctl, _("Pool %s deleted\n"), name);
} else {
vshError(ctl, _("Failed to delete pool %s"), name);
ret = false;
}
return ret;
}
/*
* "pool-refresh" command
*/
static const vshCmdInfo info_pool_refresh[] = {
{.name = "help",
.data = N_("refresh a pool")
},
{.name = "desc",
.data = N_("Refresh a given pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_refresh[] = {
VIRSH_COMMON_OPT_POOL_FULL(VIR_CONNECT_LIST_STORAGE_POOLS_ACTIVE),
{.name = NULL}
};
static bool
cmdPoolRefresh(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
bool ret = true;
const char *name;
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", &name)))
return false;
if (virStoragePoolRefresh(pool, 0) == 0) {
vshPrintExtra(ctl, _("Pool %s refreshed\n"), name);
} else {
vshError(ctl, _("Failed to refresh pool %s"), name);
ret = false;
}
return ret;
}
/*
* "pool-dumpxml" command
*/
static const vshCmdInfo info_pool_dumpxml[] = {
{.name = "help",
.data = N_("pool information in XML")
},
{.name = "desc",
.data = N_("Output the pool information as an XML dump to stdout.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_dumpxml[] = {
VIRSH_COMMON_OPT_POOL_FULL(0),
{.name = "inactive",
.type = VSH_OT_BOOL,
.help = N_("show inactive defined XML")
},
{.name = "xpath",
.type = VSH_OT_STRING,
.flags = VSH_OFLAG_REQ_OPT,
.completer = virshCompleteEmpty,
.help = N_("xpath expression to filter the XML document")
},
{.name = "wrap",
.type = VSH_OT_BOOL,
.help = N_("wrap xpath results in an common root element"),
},
{.name = NULL}
};
static bool
cmdPoolDumpXML(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
bool inactive = vshCommandOptBool(cmd, "inactive");
unsigned int flags = 0;
g_autofree char *xml = NULL;
bool wrap = vshCommandOptBool(cmd, "wrap");
const char *xpath = NULL;
if (inactive)
flags |= VIR_STORAGE_XML_INACTIVE;
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", NULL)))
return false;
if (vshCommandOptStringQuiet(ctl, cmd, "xpath", &xpath) < 0)
return false;
if (!(xml = virStoragePoolGetXMLDesc(pool, flags)))
return false;
return virshDumpXML(ctl, xml, "pool", xpath, wrap);
}
static int
virshStoragePoolSorter(const void *a, const void *b)
{
virStoragePoolPtr *pa = (virStoragePoolPtr *) a;
virStoragePoolPtr *pb = (virStoragePoolPtr *) b;
if (*pa && !*pb)
return -1;
if (!*pa)
return *pb != NULL;
return vshStrcasecmp(virStoragePoolGetName(*pa),
virStoragePoolGetName(*pb));
}
void virshStoragePoolListFree(struct virshStoragePoolList *list)
{
size_t i;
if (list && list->pools) {
for (i = 0; i < list->npools; i++) {
virshStoragePoolFree(list->pools[i]);
}
g_free(list->pools);
}
g_free(list);
}
struct virshStoragePoolList *
virshStoragePoolListCollect(vshControl *ctl,
unsigned int flags)
{
struct virshStoragePoolList *list = g_new0(struct virshStoragePoolList, 1);
size_t i;
int ret;
char **names = NULL;
virStoragePoolPtr pool;
bool success = false;
size_t deleted = 0;
int persistent;
int autostart;
int nActivePools = 0;
int nInactivePools = 0;
int nAllPools = 0;
virshControl *priv = ctl->privData;
/* try the list with flags support (0.10.2 and later) */
if ((ret = virConnectListAllStoragePools(priv->conn,
&list->pools,
flags)) >= 0) {
list->npools = ret;
goto finished;
}
/* check if the command is actually supported */
if (last_error && last_error->code == VIR_ERR_NO_SUPPORT)
goto fallback;
if (last_error && last_error->code == VIR_ERR_INVALID_ARG) {
/* try the new API again but mask non-guaranteed flags */
unsigned int newflags = flags & (VIR_CONNECT_LIST_STORAGE_POOLS_ACTIVE |
VIR_CONNECT_LIST_STORAGE_POOLS_INACTIVE);
vshResetLibvirtError();
if ((ret = virConnectListAllStoragePools(priv->conn, &list->pools,
newflags)) >= 0) {
list->npools = ret;
goto filter;
}
}
/* there was an error during the first or second call */
vshError(ctl, "%s", _("Failed to list pools"));
goto cleanup;
fallback:
/* fall back to old method (0.10.1 and older) */
vshResetLibvirtError();
/* There is no way to get the pool type */
if (VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_FILTERS_POOL_TYPE)) {
vshError(ctl, "%s", _("Filtering using --type is not supported "
"by this libvirt"));
goto cleanup;
}
/* Get the number of active pools */
if (!VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_FILTERS_ACTIVE) ||
VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_ACTIVE)) {
if ((nActivePools = virConnectNumOfStoragePools(priv->conn)) < 0) {
vshError(ctl, "%s", _("Failed to get the number of active pools "));
goto cleanup;
}
}
/* Get the number of inactive pools */
if (!VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_FILTERS_ACTIVE) ||
VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_INACTIVE)) {
if ((nInactivePools = virConnectNumOfDefinedStoragePools(priv->conn)) < 0) {
vshError(ctl, "%s", _("Failed to get the number of inactive pools"));
goto cleanup;
}
}
nAllPools = nActivePools + nInactivePools;
if (nAllPools == 0)
return list;
names = g_new0(char *, nAllPools);
/* Retrieve a list of active storage pool names */
if (!VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_FILTERS_ACTIVE) ||
VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_ACTIVE)) {
if (virConnectListStoragePools(priv->conn,
names, nActivePools) < 0) {
vshError(ctl, "%s", _("Failed to list active pools"));
goto cleanup;
}
}
/* Add the inactive storage pools to the end of the name list */
if (!VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_FILTERS_ACTIVE) ||
VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_ACTIVE)) {
if (virConnectListDefinedStoragePools(priv->conn,
&names[nActivePools],
nInactivePools) < 0) {
vshError(ctl, "%s", _("Failed to list inactive pools"));
goto cleanup;
}
}
list->pools = g_new0(virStoragePoolPtr, nAllPools);
list->npools = 0;
/* get active pools */
for (i = 0; i < nActivePools; i++) {
if (!(pool = virStoragePoolLookupByName(priv->conn, names[i])))
continue;
list->pools[list->npools++] = pool;
}
/* get inactive pools */
for (i = 0; i < nInactivePools; i++) {
if (!(pool = virStoragePoolLookupByName(priv->conn, names[i])))
continue;
list->pools[list->npools++] = pool;
}
/* truncate pools that weren't found */
deleted = nAllPools - list->npools;
filter:
/* filter list the list if the list was acquired by fallback means */
for (i = 0; i < list->npools; i++) {
pool = list->pools[i];
/* persistence filter */
if (VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_FILTERS_PERSISTENT)) {
if ((persistent = virStoragePoolIsPersistent(pool)) < 0) {
vshError(ctl, "%s", _("Failed to get pool persistence info"));
goto cleanup;
}
if (!((VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_PERSISTENT) && persistent) ||
(VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_TRANSIENT) && !persistent)))
goto remove_entry;
}
/* autostart filter */
if (VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_FILTERS_AUTOSTART)) {
if (virStoragePoolGetAutostart(pool, &autostart) < 0) {
vshError(ctl, "%s", _("Failed to get pool autostart state"));
goto cleanup;
}
if (!((VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_AUTOSTART) && autostart) ||
(VSH_MATCH(VIR_CONNECT_LIST_STORAGE_POOLS_NO_AUTOSTART) && !autostart)))
goto remove_entry;
}
/* the pool matched all filters, it may stay */
continue;
remove_entry:
/* the pool has to be removed as it failed one of the filters */
g_clear_pointer(&list->pools[i], virshStoragePoolFree);
deleted++;
}
finished:
/* sort the list */
if (list->pools && list->npools)
qsort(list->pools, list->npools,
sizeof(*list->pools), virshStoragePoolSorter);
/* truncate the list if filter simulation deleted entries */
if (deleted)
VIR_SHRINK_N(list->pools, list->npools, deleted);
success = true;
cleanup:
for (i = 0; i < nAllPools; i++)
VIR_FREE(names[i]);
if (!success) {
g_clear_pointer(&list, virshStoragePoolListFree);
}
VIR_FREE(names);
return list;
}
VIR_ENUM_DECL(virshStoragePoolState);
VIR_ENUM_IMPL(virshStoragePoolState,
VIR_STORAGE_POOL_STATE_LAST,
N_("inactive"),
N_("building"),
N_("running"),
N_("degraded"),
N_("inaccessible"));
static const char *
virshStoragePoolStateToString(int state)
{
const char *str = virshStoragePoolStateTypeToString(state);
return str ? _(str) : _("unknown");
}
/*
* "pool-list" command
*/
static const vshCmdInfo info_pool_list[] = {
{.name = "help",
.data = N_("list pools")
},
{.name = "desc",
.data = N_("Returns list of pools.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_list[] = {
{.name = "inactive",
.type = VSH_OT_BOOL,
.help = N_("list inactive pools")
},
{.name = "all",
.type = VSH_OT_BOOL,
.help = N_("list inactive & active pools")
},
{.name = "transient",
.type = VSH_OT_BOOL,
.help = N_("list transient pools")
},
{.name = "persistent",
.type = VSH_OT_BOOL,
.help = N_("list persistent pools")
},
{.name = "autostart",
.type = VSH_OT_BOOL,
.help = N_("list pools with autostart enabled")
},
{.name = "no-autostart",
.type = VSH_OT_BOOL,
.help = N_("list pools with autostart disabled")
},
{.name = "type",
.type = VSH_OT_STRING,
.completer = virshPoolTypeCompleter,
.help = N_("only list pool of specified type(s) (if supported)")
},
{.name = "details",
.type = VSH_OT_BOOL,
.help = N_("display extended details for pools")
},
{.name = "uuid",
.type = VSH_OT_BOOL,
.help = N_("list UUID of active pools only")
},
{.name = "name",
.type = VSH_OT_BOOL,
.help = N_("list name of active pools only")
},
{.name = NULL}
};
static bool
cmdPoolList(vshControl *ctl, const vshCmd *cmd G_GNUC_UNUSED)
{
virStoragePoolInfo info;
size_t i;
bool ret = false;
struct poolInfoText {
char *state;
char *autostart;
char *persistent;
char *capacity;
char *allocation;
char *available;
};
struct poolInfoText *poolInfoTexts = NULL;
unsigned int flags = VIR_CONNECT_LIST_STORAGE_POOLS_ACTIVE;
struct virshStoragePoolList *list = NULL;
const char *type = NULL;
bool details = vshCommandOptBool(cmd, "details");
bool inactive, all;
bool uuid = false;
bool name = false;
g_autoptr(vshTable) table = NULL;
inactive = vshCommandOptBool(cmd, "inactive");
all = vshCommandOptBool(cmd, "all");
VSH_EXCLUSIVE_OPTIONS_VAR(all, inactive);
if (inactive)
flags = VIR_CONNECT_LIST_STORAGE_POOLS_INACTIVE;
if (all)
flags = VIR_CONNECT_LIST_STORAGE_POOLS_ACTIVE |
VIR_CONNECT_LIST_STORAGE_POOLS_INACTIVE;
if (vshCommandOptBool(cmd, "autostart"))
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_AUTOSTART;
if (vshCommandOptBool(cmd, "no-autostart"))
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_NO_AUTOSTART;
if (vshCommandOptBool(cmd, "persistent"))
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_PERSISTENT;
if (vshCommandOptBool(cmd, "transient"))
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_TRANSIENT;
if (vshCommandOptBool(cmd, "uuid"))
uuid = true;
if (vshCommandOptBool(cmd, "name"))
name = true;
if (vshCommandOptStringReq(ctl, cmd, "type", &type) < 0)
return false;
VSH_EXCLUSIVE_OPTIONS("details", "uuid");
VSH_EXCLUSIVE_OPTIONS("details", "name");
if (type) {
int poolType = -1;
g_auto(GStrv) poolTypes = NULL;
int npoolTypes = 0;
if ((npoolTypes = vshStringToArray(type, &poolTypes)) < 0)
return false;
for (i = 0; i < npoolTypes; i++) {
if ((poolType = virStoragePoolTypeFromString(poolTypes[i])) < 0) {
vshError(ctl, _("Invalid pool type '%s'"), poolTypes[i]);
return false;
}
switch ((virStoragePoolType) poolType) {
case VIR_STORAGE_POOL_DIR:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_DIR;
break;
case VIR_STORAGE_POOL_FS:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_FS;
break;
case VIR_STORAGE_POOL_NETFS:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_NETFS;
break;
case VIR_STORAGE_POOL_LOGICAL:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_LOGICAL;
break;
case VIR_STORAGE_POOL_DISK:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_DISK;
break;
case VIR_STORAGE_POOL_ISCSI:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_ISCSI;
break;
case VIR_STORAGE_POOL_ISCSI_DIRECT:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_ISCSI_DIRECT;
break;
case VIR_STORAGE_POOL_SCSI:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_SCSI;
break;
case VIR_STORAGE_POOL_MPATH:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_MPATH;
break;
case VIR_STORAGE_POOL_RBD:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_RBD;
break;
case VIR_STORAGE_POOL_SHEEPDOG:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_SHEEPDOG;
break;
case VIR_STORAGE_POOL_GLUSTER:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_GLUSTER;
break;
case VIR_STORAGE_POOL_ZFS:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_ZFS;
break;
case VIR_STORAGE_POOL_VSTORAGE:
flags |= VIR_CONNECT_LIST_STORAGE_POOLS_VSTORAGE;
break;
case VIR_STORAGE_POOL_LAST:
break;
}
}
}
if (!(list = virshStoragePoolListCollect(ctl, flags)))
goto cleanup;
poolInfoTexts = g_new0(struct poolInfoText, list->npools);
/* Collect the storage pool information for display */
for (i = 0; i < list->npools; i++) {
int autostart = 0, persistent = 0;
/* Retrieve the autostart status of the pool */
if (virStoragePoolGetAutostart(list->pools[i], &autostart) < 0)
poolInfoTexts[i].autostart = g_strdup(_("no autostart"));
else
poolInfoTexts[i].autostart = g_strdup(autostart ? _("yes") : _("no"));
/* Retrieve the persistence status of the pool */
if (details) {
persistent = virStoragePoolIsPersistent(list->pools[i]);
vshDebug(ctl, VSH_ERR_DEBUG, "Persistent flag value: %d\n",
persistent);
if (persistent < 0)
poolInfoTexts[i].persistent = g_strdup(_("unknown"));
else
poolInfoTexts[i].persistent = g_strdup(persistent ? _("yes") : _("no"));
}
/* Collect further extended information about the pool */
if (virStoragePoolGetInfo(list->pools[i], &info) != 0) {
/* Something went wrong retrieving pool info, cope with it */
vshError(ctl, "%s", _("Could not retrieve pool information"));
poolInfoTexts[i].state = g_strdup(_("unknown"));
if (details) {
poolInfoTexts[i].capacity = g_strdup(_("unknown"));
poolInfoTexts[i].allocation = g_strdup(_("unknown"));
poolInfoTexts[i].available = g_strdup(_("unknown"));
}
} else {
/* Decide which state string to display */
if (details) {
const char *state = virshStoragePoolStateToString(info.state);
poolInfoTexts[i].state = g_strdup(state);
/* Create the pool size related strings */
if (info.state == VIR_STORAGE_POOL_RUNNING ||
info.state == VIR_STORAGE_POOL_DEGRADED) {
double val;
const char *unit;
val = vshPrettyCapacity(info.capacity, &unit);
poolInfoTexts[i].capacity = g_strdup_printf("%.2lf %s", val,
unit);
val = vshPrettyCapacity(info.allocation, &unit);
poolInfoTexts[i].allocation = g_strdup_printf("%.2lf %s", val,
unit);
val = vshPrettyCapacity(info.available, &unit);
poolInfoTexts[i].available = g_strdup_printf("%.2lf %s", val,
unit);
} else {
/* Capacity related information isn't available */
poolInfoTexts[i].capacity = g_strdup(_("-"));
poolInfoTexts[i].allocation = g_strdup(_("-"));
poolInfoTexts[i].available = g_strdup(_("-"));
}
} else {
/* --details option was not specified, only active/inactive
* state strings are used */
if (virStoragePoolIsActive(list->pools[i]))
poolInfoTexts[i].state = g_strdup(_("active"));
else
poolInfoTexts[i].state = g_strdup(_("inactive"));
}
}
}
/* If the --details option wasn't selected, we output the pool
* info using the fixed string format from previous versions to
* maintain backward compatibility.
*/
/* Output basic info then return if --details option not selected */
if (!details) {
if (uuid || name) {
for (i = 0; i < list->npools; i++) {
if (uuid) {
char uuid_str[VIR_UUID_STRING_BUFLEN];
virStoragePoolGetUUIDString(list->pools[i], uuid_str);
vshPrint(ctl, "%-36s%c", uuid_str, name ? ' ': '\n');
}
if (name) {
const char *name_str =
virStoragePoolGetName(list->pools[i]);
vshPrint(ctl, "%-20s\n", name_str);
}
}
ret = true;
goto cleanup;
}
/* Output old style header */
table = vshTableNew(_("Name"), _("State"), _("Autostart"), NULL);
if (!table)
goto cleanup;
/* Output old style pool info */
for (i = 0; i < list->npools; i++) {
const char *name_str = virStoragePoolGetName(list->pools[i]);
if (vshTableRowAppend(table,
name_str,
poolInfoTexts[i].state,
poolInfoTexts[i].autostart,
NULL) < 0)
goto cleanup;
}
vshTablePrintToStdout(table, ctl);
/* Cleanup and return */
ret = true;
goto cleanup;
}
/* We only get here if the --details option was selected. */
/* Insert the header into table */
table = vshTableNew(_("Name"), _("State"), _("Autostart"), _("Persistent"),
_("Capacity"), _("Allocation"), _("Available"), NULL);
if (!table)
goto cleanup;
/* Insert the pool info rows into table */
for (i = 0; i < list->npools; i++) {
if (vshTableRowAppend(table,
virStoragePoolGetName(list->pools[i]),
poolInfoTexts[i].state,
poolInfoTexts[i].autostart,
poolInfoTexts[i].persistent,
poolInfoTexts[i].capacity,
poolInfoTexts[i].allocation,
poolInfoTexts[i].available,
NULL) < 0)
goto cleanup;
}
vshTablePrintToStdout(table, ctl);
/* Cleanup and return */
ret = true;
cleanup:
if (list && list->npools) {
for (i = 0; i < list->npools; i++) {
VIR_FREE(poolInfoTexts[i].state);
VIR_FREE(poolInfoTexts[i].autostart);
VIR_FREE(poolInfoTexts[i].persistent);
VIR_FREE(poolInfoTexts[i].capacity);
VIR_FREE(poolInfoTexts[i].allocation);
VIR_FREE(poolInfoTexts[i].available);
}
}
VIR_FREE(poolInfoTexts);
virshStoragePoolListFree(list);
return ret;
}
/*
* "find-storage-pool-sources-as" command
*/
static const vshCmdInfo info_find_storage_pool_sources_as[] = {
{.name = "help",
.data = N_("find potential storage pool sources")
},
{.name = "desc",
.data = N_("Returns XML <sources> document.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_find_storage_pool_sources_as[] = {
{.name = "type",
.type = VSH_OT_DATA,
.flags = VSH_OFLAG_REQ,
.help = N_("type of storage pool sources to find")
},
{.name = "host",
.type = VSH_OT_STRING,
.completer = virshCompleteEmpty,
.help = N_("optional host to query")
},
{.name = "port",
.type = VSH_OT_STRING,
.completer = virshCompleteEmpty,
.help = N_("optional port to query")
},
{.name = "initiator",
.type = VSH_OT_STRING,
.completer = virshCompleteEmpty,
.help = N_("optional initiator IQN to use for query")
},
{.name = NULL}
};
static bool
cmdPoolDiscoverSourcesAs(vshControl * ctl, const vshCmd * cmd G_GNUC_UNUSED)
{
const char *type = NULL, *host = NULL;
g_autofree char *srcSpec = NULL;
g_autofree char *srcList = NULL;
const char *initiator = NULL;
virshControl *priv = ctl->privData;
if (vshCommandOptStringReq(ctl, cmd, "type", &type) < 0 ||
vshCommandOptStringReq(ctl, cmd, "host", &host) < 0 ||
vshCommandOptStringReq(ctl, cmd, "initiator", &initiator) < 0)
return false;
if (host) {
const char *port = NULL;
g_auto(virBuffer) buf = VIR_BUFFER_INITIALIZER;
if (vshCommandOptStringReq(ctl, cmd, "port", &port) < 0) {
vshError(ctl, "%s", _("missing argument"));
return false;
}
virBufferAddLit(&buf, "<source>\n");
virBufferAdjustIndent(&buf, 2);
virBufferAsprintf(&buf, "<host name='%s'", host);
if (port)
virBufferAsprintf(&buf, " port='%s'", port);
virBufferAddLit(&buf, "/>\n");
if (initiator) {
virBufferAddLit(&buf, "<initiator>\n");
virBufferAdjustIndent(&buf, 2);
virBufferAsprintf(&buf, "<iqn name='%s'/>\n", initiator);
virBufferAdjustIndent(&buf, -2);
virBufferAddLit(&buf, "</initiator>\n");
}
virBufferAdjustIndent(&buf, -2);
virBufferAddLit(&buf, "</source>\n");
srcSpec = virBufferContentAndReset(&buf);
}
srcList = virConnectFindStoragePoolSources(priv->conn, type, srcSpec, 0);
if (srcList == NULL) {
vshError(ctl, _("Failed to find any %s pool sources"), type);
return false;
}
vshPrint(ctl, "%s", srcList);
return true;
}
/*
* "find-storage-pool-sources" command
*/
static const vshCmdInfo info_find_storage_pool_sources[] = {
{.name = "help",
.data = N_("discover potential storage pool sources")
},
{.name = "desc",
.data = N_("Returns XML <sources> document.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_find_storage_pool_sources[] = {
{.name = "type",
.type = VSH_OT_DATA,
.flags = VSH_OFLAG_REQ,
.help = N_("type of storage pool sources to discover")
},
{.name = "srcSpec",
.type = VSH_OT_STRING,
.completer = virshCompletePathLocalExisting,
.help = N_("optional file of source xml to query for pools")
},
{.name = NULL}
};
static bool
cmdPoolDiscoverSources(vshControl * ctl, const vshCmd * cmd G_GNUC_UNUSED)
{
const char *type = NULL, *srcSpecFile = NULL;
char *srcSpec = NULL, *srcList;
virshControl *priv = ctl->privData;
if (vshCommandOptStringReq(ctl, cmd, "type", &type) < 0)
return false;
if (vshCommandOptStringReq(ctl, cmd, "srcSpec", &srcSpecFile) < 0)
return false;
if (srcSpecFile && virFileReadAll(srcSpecFile, VSH_MAX_XML_FILE,
&srcSpec) < 0)
return false;
srcList = virConnectFindStoragePoolSources(priv->conn, type, srcSpec, 0);
VIR_FREE(srcSpec);
if (srcList == NULL) {
vshError(ctl, _("Failed to find any %s pool sources"), type);
return false;
}
vshPrint(ctl, "%s", srcList);
VIR_FREE(srcList);
return true;
}
/*
* "pool-info" command
*/
static const vshCmdInfo info_pool_info[] = {
{.name = "help",
.data = N_("storage pool information")
},
{.name = "desc",
.data = N_("Returns basic information about the storage pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_info[] = {
VIRSH_COMMON_OPT_POOL_FULL(0),
{.name = "bytes",
.type = VSH_OT_BOOL,
.help = N_("Return pool info in bytes"),
},
{.name = NULL}
};
static bool
cmdPoolInfo(vshControl *ctl, const vshCmd *cmd)
{
virStoragePoolInfo info;
g_autoptr(virshStoragePool) pool = NULL;
int autostart = 0;
bool ret = true;
bool bytes = false;
char uuid[VIR_UUID_STRING_BUFLEN];
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", NULL)))
return false;
bytes = vshCommandOptBool(cmd, "bytes");
vshPrint(ctl, "%-15s %s\n", _("Name:"), virStoragePoolGetName(pool));
if (virStoragePoolGetUUIDString(pool, &uuid[0]) == 0)
vshPrint(ctl, "%-15s %s\n", _("UUID:"), uuid);
if (virStoragePoolGetInfo(pool, &info) == 0) {
double val;
const char *unit;
int persistent;
vshPrint(ctl, "%-15s %s\n", _("State:"),
virshStoragePoolStateToString(info.state));
/* Check and display whether the pool is persistent or not */
persistent = virStoragePoolIsPersistent(pool);
vshDebug(ctl, VSH_ERR_DEBUG, "Pool persistent flag value: %d\n",
persistent);
if (persistent < 0)
vshPrint(ctl, "%-15s %s\n", _("Persistent:"), _("unknown"));
else
vshPrint(ctl, "%-15s %s\n", _("Persistent:"), persistent ? _("yes") : _("no"));
/* Check and display whether the pool is autostarted or not */
if (virStoragePoolGetAutostart(pool, &autostart) < 0)
vshPrint(ctl, "%-15s %s\n", _("Autostart:"), _("no autostart"));
else
vshPrint(ctl, "%-15s %s\n", _("Autostart:"), autostart ? _("yes") : _("no"));
if (info.state == VIR_STORAGE_POOL_RUNNING ||
info.state == VIR_STORAGE_POOL_DEGRADED) {
if (bytes) {
vshPrint(ctl, "%-15s %llu\n", _("Capacity:"), info.capacity);
vshPrint(ctl, "%-15s %llu\n", _("Allocation:"), info.allocation);
vshPrint(ctl, "%-15s %llu\n", _("Available:"), info.available);
} else {
val = vshPrettyCapacity(info.capacity, &unit);
vshPrint(ctl, "%-15s %2.2lf %s\n", _("Capacity:"), val, unit);
val = vshPrettyCapacity(info.allocation, &unit);
vshPrint(ctl, "%-15s %2.2lf %s\n", _("Allocation:"), val, unit);
val = vshPrettyCapacity(info.available, &unit);
vshPrint(ctl, "%-15s %2.2lf %s\n", _("Available:"), val, unit);
}
}
} else {
ret = false;
}
return ret;
}
/*
* "pool-name" command
*/
static const vshCmdInfo info_pool_name[] = {
{.name = "help",
.data = N_("convert a pool UUID to pool name")
},
{.name = "desc",
.data = ""
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_name[] = {
VIRSH_COMMON_OPT_POOL_FULL(0),
{.name = NULL}
};
static bool
cmdPoolName(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
if (!(pool = virshCommandOptPoolBy(ctl, cmd, "pool", NULL, VIRSH_BYUUID)))
return false;
vshPrint(ctl, "%s\n", virStoragePoolGetName(pool));
return true;
}
/*
* "pool-start" command
*/
static const vshCmdInfo info_pool_start[] = {
{.name = "help",
.data = N_("start a (previously defined) inactive pool")
},
{.name = "desc",
.data = N_("Start a pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_start[] = {
VIRSH_COMMON_OPT_POOL_FULL(VIR_CONNECT_LIST_STORAGE_POOLS_INACTIVE),
VIRSH_COMMON_OPT_POOL_BUILD,
VIRSH_COMMON_OPT_POOL_NO_OVERWRITE,
VIRSH_COMMON_OPT_POOL_OVERWRITE,
{.name = NULL}
};
static bool
cmdPoolStart(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
bool ret = true;
const char *name = NULL;
bool build;
bool overwrite;
bool no_overwrite;
unsigned int flags = 0;
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", &name)))
return false;
build = vshCommandOptBool(cmd, "build");
overwrite = vshCommandOptBool(cmd, "overwrite");
no_overwrite = vshCommandOptBool(cmd, "no-overwrite");
VSH_EXCLUSIVE_OPTIONS_EXPR("overwrite", overwrite,
"no-overwrite", no_overwrite);
if (build)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD;
if (overwrite)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD_OVERWRITE;
if (no_overwrite)
flags |= VIR_STORAGE_POOL_CREATE_WITH_BUILD_NO_OVERWRITE;
if (virStoragePoolCreate(pool, flags) == 0) {
vshPrintExtra(ctl, _("Pool %s started\n"), name);
} else {
vshError(ctl, _("Failed to start pool %s"), name);
ret = false;
}
return ret;
}
/*
* "pool-undefine" command
*/
static const vshCmdInfo info_pool_undefine[] = {
{.name = "help",
.data = N_("undefine an inactive pool")
},
{.name = "desc",
.data = N_("Undefine the configuration for an inactive pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_undefine[] = {
VIRSH_COMMON_OPT_POOL_FULL(VIR_CONNECT_LIST_STORAGE_POOLS_PERSISTENT),
{.name = NULL}
};
static bool
cmdPoolUndefine(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
bool ret = true;
const char *name;
if (!(pool = virshCommandOptPool(ctl, cmd, "pool", &name)))
return false;
if (virStoragePoolUndefine(pool) == 0) {
vshPrintExtra(ctl, _("Pool %s has been undefined\n"), name);
} else {
vshError(ctl, _("Failed to undefine pool %s"), name);
ret = false;
}
return ret;
}
/*
* "pool-uuid" command
*/
static const vshCmdInfo info_pool_uuid[] = {
{.name = "help",
.data = N_("convert a pool name to pool UUID")
},
{.name = "desc",
.data = ""
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_uuid[] = {
VIRSH_COMMON_OPT_POOL_FULL(0),
{.name = NULL}
};
static bool
cmdPoolUuid(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
char uuid[VIR_UUID_STRING_BUFLEN];
if (!(pool = virshCommandOptPoolBy(ctl, cmd, "pool", NULL, VIRSH_BYNAME)))
return false;
if (virStoragePoolGetUUIDString(pool, uuid) != -1)
vshPrint(ctl, "%s\n", uuid);
else
vshError(ctl, "%s", _("failed to get pool UUID"));
return true;
}
/*
* "pool-edit" command
*/
static const vshCmdInfo info_pool_edit[] = {
{.name = "help",
.data = N_("edit XML configuration for a storage pool")
},
{.name = "desc",
.data = N_("Edit the XML configuration for a storage pool.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_edit[] = {
VIRSH_COMMON_OPT_POOL_FULL(0),
{.name = NULL}
};
static bool
cmdPoolEdit(vshControl *ctl, const vshCmd *cmd)
{
bool ret = false;
g_autoptr(virshStoragePool) pool = NULL;
g_autoptr(virshStoragePool) pool_edited = NULL;
unsigned int flags = VIR_STORAGE_XML_INACTIVE;
g_autofree char *tmp_desc = NULL;
virshControl *priv = ctl->privData;
pool = virshCommandOptPool(ctl, cmd, "pool", NULL);
if (pool == NULL)
goto cleanup;
/* Some old daemons don't support _INACTIVE flag */
if (!(tmp_desc = virStoragePoolGetXMLDesc(pool, flags))) {
if (last_error->code == VIR_ERR_INVALID_ARG) {
flags &= ~VIR_STORAGE_XML_INACTIVE;
vshResetLibvirtError();
} else {
goto cleanup;
}
}
#define EDIT_GET_XML virStoragePoolGetXMLDesc(pool, flags)
#define EDIT_NOT_CHANGED \
do { \
vshPrintExtra(ctl, _("Pool %s XML configuration not changed.\n"), \
virStoragePoolGetName(pool)); \
ret = true; \
goto edit_cleanup; \
} while (0)
#define EDIT_DEFINE \
(pool_edited = virStoragePoolDefineXML(priv->conn, doc_edited, 0))
#include "virsh-edit.c"
vshPrintExtra(ctl, _("Pool %s XML configuration edited.\n"),
virStoragePoolGetName(pool_edited));
ret = true;
cleanup:
return ret;
}
/*
* "pool-event" command
*/
VIR_ENUM_DECL(virshPoolEvent);
VIR_ENUM_IMPL(virshPoolEvent,
VIR_STORAGE_POOL_EVENT_LAST,
N_("Defined"),
N_("Undefined"),
N_("Started"),
N_("Stopped"),
N_("Created"),
N_("Deleted"));
static const char *
virshPoolEventToString(int event)
{
const char *str = virshPoolEventTypeToString(event);
return str ? _(str) : _("unknown");
}
struct virshPoolEventData {
vshControl *ctl;
bool loop;
bool timestamp;
int count;
virshPoolEventCallback *cb;
};
typedef struct virshPoolEventData virshPoolEventData;
static void
vshEventLifecyclePrint(virConnectPtr conn G_GNUC_UNUSED,
virStoragePoolPtr pool,
int event,
int detail G_GNUC_UNUSED,
void *opaque)
{
virshPoolEventData *data = opaque;
if (!data->loop && data->count)
return;
if (data->timestamp) {
char timestamp[VIR_TIME_STRING_BUFLEN];
if (virTimeStringNowRaw(timestamp) < 0)
timestamp[0] = '\0';
vshPrint(data->ctl, _("%s: event 'lifecycle' for storage pool %s: %s\n"),
timestamp,
virStoragePoolGetName(pool),
virshPoolEventToString(event));
} else {
vshPrint(data->ctl, _("event 'lifecycle' for storage pool %s: %s\n"),
virStoragePoolGetName(pool),
virshPoolEventToString(event));
}
data->count++;
if (!data->loop)
vshEventDone(data->ctl);
}
static void
vshEventGenericPrint(virConnectPtr conn G_GNUC_UNUSED,
virStoragePoolPtr pool,
void *opaque)
{
virshPoolEventData *data = opaque;
if (!data->loop && data->count)
return;
if (data->timestamp) {
char timestamp[VIR_TIME_STRING_BUFLEN];
if (virTimeStringNowRaw(timestamp) < 0)
timestamp[0] = '\0';
vshPrint(data->ctl, _("%s: event '%s' for storage pool %s\n"),
timestamp,
data->cb->name,
virStoragePoolGetName(pool));
} else {
vshPrint(data->ctl, _("event '%s' for storage pool %s\n"),
data->cb->name,
virStoragePoolGetName(pool));
}
data->count++;
if (!data->loop)
vshEventDone(data->ctl);
}
virshPoolEventCallback virshPoolEventCallbacks[] = {
{ "lifecycle",
VIR_STORAGE_POOL_EVENT_CALLBACK(vshEventLifecyclePrint), },
{ "refresh", vshEventGenericPrint, }
};
G_STATIC_ASSERT(VIR_STORAGE_POOL_EVENT_ID_LAST == G_N_ELEMENTS(virshPoolEventCallbacks));
static const vshCmdInfo info_pool_event[] = {
{.name = "help",
.data = N_("Storage Pool Events")
},
{.name = "desc",
.data = N_("List event types, or wait for storage pool events to occur")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_event[] = {
{.name = "pool",
.type = VSH_OT_STRING,
.completer = virshStoragePoolNameCompleter,
.help = N_("filter by storage pool name or uuid")
},
{.name = "event",
.type = VSH_OT_STRING,
.completer = virshPoolEventNameCompleter,
.help = N_("which event type to wait for")
},
{.name = "loop",
.type = VSH_OT_BOOL,
.help = N_("loop until timeout or interrupt, rather than one-shot")
},
{.name = "timeout",
.type = VSH_OT_INT,
.help = N_("timeout seconds")
},
{.name = "list",
.type = VSH_OT_BOOL,
.help = N_("list valid event types")
},
{.name = "timestamp",
.type = VSH_OT_BOOL,
.help = N_("show timestamp for each printed event")
},
{.name = NULL}
};
static bool
cmdPoolEvent(vshControl *ctl, const vshCmd *cmd)
{
g_autoptr(virshStoragePool) pool = NULL;
bool ret = false;
int eventId = -1;
int timeout = 0;
virshPoolEventData data;
const char *eventName = NULL;
int event;
virshControl *priv = ctl->privData;
if (vshCommandOptBool(cmd, "list")) {
size_t i;
for (i = 0; i < VIR_STORAGE_POOL_EVENT_ID_LAST; i++)
vshPrint(ctl, "%s\n", virshPoolEventCallbacks[i].name);
return true;
}
if (vshCommandOptStringReq(ctl, cmd, "event", &eventName) < 0)
return false;
if (!eventName) {
vshError(ctl, "%s", _("either --list or --event <type> is required"));
return false;
}
for (event = 0; event < VIR_STORAGE_POOL_EVENT_ID_LAST; event++)
if (STREQ(eventName, virshPoolEventCallbacks[event].name))
break;
if (event == VIR_STORAGE_POOL_EVENT_ID_LAST) {
vshError(ctl, _("unknown event type %s"), eventName);
return false;
}
data.ctl = ctl;
data.loop = vshCommandOptBool(cmd, "loop");
data.timestamp = vshCommandOptBool(cmd, "timestamp");
data.count = 0;
data.cb = &virshPoolEventCallbacks[event];
if (vshCommandOptTimeoutToMs(ctl, cmd, &timeout) < 0)
return false;
if (vshCommandOptBool(cmd, "pool"))
pool = virshCommandOptPool(ctl, cmd, "pool", NULL);
if (vshEventStart(ctl, timeout) < 0)
goto cleanup;
if ((eventId = virConnectStoragePoolEventRegisterAny(priv->conn, pool, event,
data.cb->cb,
&data, NULL)) < 0)
goto cleanup;
switch (vshEventWait(ctl)) {
case VSH_EVENT_INTERRUPT:
vshPrint(ctl, "%s", _("event loop interrupted\n"));
break;
case VSH_EVENT_TIMEOUT:
vshPrint(ctl, "%s", _("event loop timed out\n"));
break;
case VSH_EVENT_DONE:
break;
default:
goto cleanup;
}
vshPrint(ctl, _("events received: %d\n"), data.count);
if (data.count)
ret = true;
cleanup:
vshEventCleanup(ctl);
if (eventId >= 0 &&
virConnectStoragePoolEventDeregisterAny(priv->conn, eventId) < 0)
ret = false;
return ret;
}
/*
* "pool-capabilities" command
*/
static const vshCmdInfo info_pool_capabilities[] = {
{.name = "help",
.data = N_("storage pool capabilities")
},
{.name = "desc",
.data = N_("Returns capabilities of storage pool support.")
},
{.name = NULL}
};
static const vshCmdOptDef opts_pool_capabilities[] = {
{.name = NULL}
};
static bool
cmdPoolCapabilities(vshControl *ctl,
const vshCmd *cmd G_GNUC_UNUSED)
{
const unsigned int flags = 0; /* No flags so far */
virshControl *priv = ctl->privData;
g_autofree char *caps = NULL;
caps = virConnectGetStoragePoolCapabilities(priv->conn, flags);
if (!caps) {
vshError(ctl, "%s", _("failed to get storage pool capabilities"));
return false;
}
vshPrint(ctl, "%s\n", caps);
return true;
}
const vshCmdDef storagePoolCmds[] = {
{.name = "find-storage-pool-sources-as",
.handler = cmdPoolDiscoverSourcesAs,
.opts = opts_find_storage_pool_sources_as,
.info = info_find_storage_pool_sources_as,
.flags = 0
},
{.name = "find-storage-pool-sources",
.handler = cmdPoolDiscoverSources,
.opts = opts_find_storage_pool_sources,
.info = info_find_storage_pool_sources,
.flags = 0
},
{.name = "pool-autostart",
.handler = cmdPoolAutostart,
.opts = opts_pool_autostart,
.info = info_pool_autostart,
.flags = 0
},
{.name = "pool-build",
.handler = cmdPoolBuild,
.opts = opts_pool_build,
.info = info_pool_build,
.flags = 0
},
{.name = "pool-create-as",
.handler = cmdPoolCreateAs,
.opts = opts_pool_create_as,
.info = info_pool_create_as,
.flags = 0
},
{.name = "pool-create",
.handler = cmdPoolCreate,
.opts = opts_pool_create,
.info = info_pool_create,
.flags = 0
},
{.name = "pool-define-as",
.handler = cmdPoolDefineAs,
.opts = opts_pool_define_as,
.info = info_pool_define_as,
.flags = 0
},
{.name = "pool-define",
.handler = cmdPoolDefine,
.opts = opts_pool_define,
.info = info_pool_define,
.flags = 0
},
{.name = "pool-delete",
.handler = cmdPoolDelete,
.opts = opts_pool_delete,
.info = info_pool_delete,
.flags = 0
},
{.name = "pool-destroy",
.handler = cmdPoolDestroy,
.opts = opts_pool_destroy,
.info = info_pool_destroy,
.flags = 0
},
{.name = "pool-dumpxml",
.handler = cmdPoolDumpXML,
.opts = opts_pool_dumpxml,
.info = info_pool_dumpxml,
.flags = 0
},
{.name = "pool-edit",
.handler = cmdPoolEdit,
.opts = opts_pool_edit,
.info = info_pool_edit,
.flags = 0
},
{.name = "pool-info",
.handler = cmdPoolInfo,
.opts = opts_pool_info,
.info = info_pool_info,
.flags = 0
},
{.name = "pool-list",
.handler = cmdPoolList,
.opts = opts_pool_list,
.info = info_pool_list,
.flags = 0
},
{.name = "pool-name",
.handler = cmdPoolName,
.opts = opts_pool_name,
.info = info_pool_name,
.flags = 0
},
{.name = "pool-refresh",
.handler = cmdPoolRefresh,
.opts = opts_pool_refresh,
.info = info_pool_refresh,
.flags = 0
},
{.name = "pool-start",
.handler = cmdPoolStart,
.opts = opts_pool_start,
.info = info_pool_start,
.flags = 0
},
{.name = "pool-undefine",
.handler = cmdPoolUndefine,
.opts = opts_pool_undefine,
.info = info_pool_undefine,
.flags = 0
},
{.name = "pool-uuid",
.handler = cmdPoolUuid,
.opts = opts_pool_uuid,
.info = info_pool_uuid,
.flags = 0
},
{.name = "pool-event",
.handler = cmdPoolEvent,
.opts = opts_pool_event,
.info = info_pool_event,
.flags = 0
},
{.name = "pool-capabilities",
.handler = cmdPoolCapabilities,
.opts = opts_pool_capabilities,
.info = info_pool_capabilities,
.flags = 0
},
{.name = NULL}
};