2014-03-12 22:07:13 +08:00
|
|
|
-------------------------------
|
|
|
|
BCM590xx Power Management Units
|
|
|
|
-------------------------------
|
|
|
|
|
|
|
|
Required properties:
|
|
|
|
- compatible: "brcm,bcm59056"
|
|
|
|
- reg: I2C slave address
|
|
|
|
- interrupts: interrupt for the PMU. Generic interrupt client node bindings
|
|
|
|
are described in interrupt-controller/interrupts.txt
|
|
|
|
|
|
|
|
------------------
|
|
|
|
Voltage Regulators
|
|
|
|
------------------
|
|
|
|
|
|
|
|
Optional child nodes:
|
|
|
|
- regulators: container node for regulators following the generic
|
|
|
|
regulator binding in regulator/regulator.txt
|
|
|
|
|
|
|
|
The valid regulator node names for BCM59056 are:
|
|
|
|
rfldo, camldo1, camldo2, simldo1, simldo2, sdldo, sdxldo,
|
|
|
|
mmcldo1, mmcldo2, audldo, micldo, usbldo, vibldo,
|
2014-04-24 07:21:30 +08:00
|
|
|
csr, iosr1, iosr2, msr, sdsr1, sdsr2, vsr,
|
|
|
|
gpldo1, gpldo2, gpldo3, gpldo4, gpldo5, gpldo6,
|
|
|
|
vbus
|
2014-03-12 22:07:13 +08:00
|
|
|
|
|
|
|
Example:
|
|
|
|
pmu: bcm59056@8 {
|
|
|
|
compatible = "brcm,bcm59056";
|
|
|
|
reg = <0x08>;
|
|
|
|
interrupts = <GIC_SPI 215 IRQ_TYPE_LEVEL_HIGH>;
|
|
|
|
regulators {
|
|
|
|
rfldo_reg: rfldo {
|
|
|
|
regulator-min-microvolt = <1200000>;
|
|
|
|
regulator-max-microvolt = <3300000>;
|
|
|
|
};
|
|
|
|
|
|
|
|
...
|
|
|
|
};
|
|
|
|
};
|