ALSA: oxygen: fix analog capture on Claro halo cards

On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input.  Using the default first input, which isn't connected
to anything, would result in silence.

Signed-off-by: Erik J. Staab <ejs@insightbb.com>
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Cc: <stable@kernel.org>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
Erik J. Staab 2010-09-22 11:07:41 +02:00 committed by Takashi Iwai
parent b30a3f6257
commit 0873a5ae74
1 changed files with 4 additions and 0 deletions

View File

@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip,
chip->model.suspend = claro_suspend;
chip->model.resume = claro_resume;
chip->model.set_adc_params = set_ak5385_params;
chip->model.device_config = PLAYBACK_0_TO_I2S |
PLAYBACK_1_TO_SPDIF |
CAPTURE_0_FROM_I2S_2 |
CAPTURE_1_FROM_SPDIF;
break;
}
if (id->driver_data == MODEL_MERIDIAN ||