ARM: dts: dra71-evm: Select pull down for mmc1_clk line in default mode

During a short period when the bus voltage is switched from 3.3v to 1.8v,
(to enumerate UHS mode), the mmc module is disabled and the mmc IO lines
are kept in a state according to the programmed pad mux pull type.

According to 4.2.4.2 Timing to Switch Signal Voltage in "SD Specifications
Part 1 Physical Layer Specification Version 5.00 February 22, 2016", the
host should hold CLK low for at least 5ms.

In order to keep the card line low during voltage switch, the pad mux of
mmc1_clk line should be configured to pull down.

This is specific only to dra71-evm (and not all dra72 based boards) since
mmc1_clk line in dra71-evm is not connected to an external pullup.

Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
This commit is contained in:
Kishon Vijay Abraham I 2018-02-06 18:28:03 +05:30 committed by Tony Lindgren
parent f4aa1bd5b4
commit 0e43884cca
1 changed files with 13 additions and 0 deletions

View File

@ -50,6 +50,19 @@ poweroff: gpio-poweroff {
};
};
&dra7_pmx_core {
mmc1_pins_default: mmc1_pins_default {
pinctrl-single,pins = <
DRA7XX_CORE_IOPAD(0x3754, PIN_INPUT_PULLDOWN | MUX_MODE0) /* mmc1_clk.clk */
DRA7XX_CORE_IOPAD(0x3758, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_cmd.cmd */
DRA7XX_CORE_IOPAD(0x375c, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat0.dat0 */
DRA7XX_CORE_IOPAD(0x3760, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat1.dat1 */
DRA7XX_CORE_IOPAD(0x3764, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat2.dat2 */
DRA7XX_CORE_IOPAD(0x3768, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat3.dat3 */
>;
};
};
&i2c1 {
status = "okay";
clock-frequency = <400000>;