mirror of https://gitee.com/openkylin/linux.git
watchdog: sp5100_tco: Fix wrong indirect I/O access for getting value of reserved bits
In case of SB800 or later chipset and re-programming MMIO address(*), sp5100_tco module may read incorrect value of reserved bit, because the module reads a value from an incorrect I/O address. However, this bug doesn't cause a problem, because when re-programming MMIO address, by chance the module writes zero (this is BIOS's default value) to the low three bits of register. * In most cases, PC with SB8x0 or later chipset doesn't need to re-programming MMIO address, because such PC can enable AcpiMmio and can use 0xfed80b00 for watchdog register base address. This patch fixes this bug. Bugzilla: https://bugzilla.kernel.org/show_bug.cgi?id=43176 Signed-off-by: Takahisa Tanaka <mc74hc00@gmail.com> Tested-by: Paul Menzel <paulepanter@users.sourceforge.net> Signed-off-by: Wim Van Sebroeck <wim@iguana.be> Cc: stable <stable@vger.kernel.org>
This commit is contained in:
parent
6737176569
commit
10ab329b5d
|
@ -500,14 +500,15 @@ static unsigned char sp5100_tco_setupdevice(void)
|
|||
/* Restore to the low three bits, if chipset is SB8x0(or later) */
|
||||
if (sp5100_tco_pci->revision >= 0x40) {
|
||||
u8 reserved_bit;
|
||||
reserved_bit = inb(base_addr) & 0x7;
|
||||
outb(base_addr+0, index_reg);
|
||||
reserved_bit = inb(data_reg) & 0x7;
|
||||
val |= (u32)reserved_bit;
|
||||
}
|
||||
|
||||
/* Re-programming the watchdog timer base address */
|
||||
outb(base_addr+0, index_reg);
|
||||
/* Low three bits of BASE are reserved */
|
||||
outb((val >> 0) & 0xf8, data_reg);
|
||||
outb((val >> 0) & 0xff, data_reg);
|
||||
outb(base_addr+1, index_reg);
|
||||
outb((val >> 8) & 0xff, data_reg);
|
||||
outb(base_addr+2, index_reg);
|
||||
|
|
Loading…