mirror of https://gitee.com/openkylin/linux.git
drm/amdgpu: fix concurrent VM flushes on Vega/Navi v2
Starting with Vega the hardware supports concurrent flushes of VMID which can be used to implement per process VMID allocation. But concurrent flushes are mutual exclusive with back to back VMID allocations, fix this to avoid a VMID used in two ways at the same time. v2: don't set ring to NULL Signed-off-by: Christian König <christian.koenig@amd.com> Reviewed-by: James Zhu <James.Zhu@amd.com> Tested-by: James Zhu <James.Zhu@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com> Cc: stable@vger.kernel.org
This commit is contained in:
parent
d89f6048bd
commit
20a5f5a98e
|
@ -215,7 +215,11 @@ static int amdgpu_vmid_grab_idle(struct amdgpu_vm *vm,
|
|||
/* Check if we have an idle VMID */
|
||||
i = 0;
|
||||
list_for_each_entry((*idle), &id_mgr->ids_lru, list) {
|
||||
fences[i] = amdgpu_sync_peek_fence(&(*idle)->active, ring);
|
||||
/* Don't use per engine and per process VMID at the same time */
|
||||
struct amdgpu_ring *r = adev->vm_manager.concurrent_flush ?
|
||||
NULL : ring;
|
||||
|
||||
fences[i] = amdgpu_sync_peek_fence(&(*idle)->active, r);
|
||||
if (!fences[i])
|
||||
break;
|
||||
++i;
|
||||
|
@ -290,6 +294,10 @@ static int amdgpu_vmid_grab_reserved(struct amdgpu_vm *vm,
|
|||
!dma_fence_is_signaled((*id)->last_flush))) {
|
||||
struct dma_fence *tmp;
|
||||
|
||||
/* Don't use per engine and per process VMID at the same time */
|
||||
if (adev->vm_manager.concurrent_flush)
|
||||
ring = NULL;
|
||||
|
||||
/* to prevent one context starved by another context */
|
||||
(*id)->pd_gpu_addr = 0;
|
||||
tmp = amdgpu_sync_peek_fence(&(*id)->active, ring);
|
||||
|
@ -365,12 +373,7 @@ static int amdgpu_vmid_grab_used(struct amdgpu_vm *vm,
|
|||
if (updates && (!flushed || dma_fence_is_later(updates, flushed)))
|
||||
needs_flush = true;
|
||||
|
||||
/* Concurrent flushes are only possible starting with Vega10 and
|
||||
* are broken on Navi10 and Navi14.
|
||||
*/
|
||||
if (needs_flush && (adev->asic_type < CHIP_VEGA10 ||
|
||||
adev->asic_type == CHIP_NAVI10 ||
|
||||
adev->asic_type == CHIP_NAVI14))
|
||||
if (needs_flush && !adev->vm_manager.concurrent_flush)
|
||||
continue;
|
||||
|
||||
/* Good, we can use this VMID. Remember this submission as
|
||||
|
|
|
@ -3148,6 +3148,12 @@ void amdgpu_vm_manager_init(struct amdgpu_device *adev)
|
|||
{
|
||||
unsigned i;
|
||||
|
||||
/* Concurrent flushes are only possible starting with Vega10 and
|
||||
* are broken on Navi10 and Navi14.
|
||||
*/
|
||||
adev->vm_manager.concurrent_flush = !(adev->asic_type < CHIP_VEGA10 ||
|
||||
adev->asic_type == CHIP_NAVI10 ||
|
||||
adev->asic_type == CHIP_NAVI14);
|
||||
amdgpu_vmid_mgr_init(adev);
|
||||
|
||||
adev->vm_manager.fence_context =
|
||||
|
|
|
@ -331,6 +331,7 @@ struct amdgpu_vm_manager {
|
|||
/* Handling of VMIDs */
|
||||
struct amdgpu_vmid_mgr id_mgr[AMDGPU_MAX_VMHUBS];
|
||||
unsigned int first_kfd_vmid;
|
||||
bool concurrent_flush;
|
||||
|
||||
/* Handling of VM fences */
|
||||
u64 fence_context;
|
||||
|
|
Loading…
Reference in New Issue