bnx2x: Fix over current port display

On 57712 chip, port number is enumerated per engine, so it requires adjustment in port display to the user.

Signed-off-by: Yaniv Rosner <yanivr@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Yaniv Rosner 2011-05-31 21:27:48 +00:00 committed by David S. Miller
parent c688fe2fc0
commit 27d024321c
1 changed files with 7 additions and 6 deletions

View File

@ -4919,15 +4919,14 @@ static void bnx2x_8727_power_module(struct bnx2x *bp,
*/
if (phy->flags & FLAGS_NOC)
return;
if (!(phy->flags &
FLAGS_NOC) && is_power_up)
if (is_power_up)
val = (1<<4);
else
/*
* Set GPIO control to OUTPUT, and set the power bit
* to according to the is_power_up
*/
val = ((!(is_power_up)) << 1);
val = (1<<1);
bnx2x_cl45_write(bp, phy,
MDIO_PMA_DEVAD,
@ -5928,7 +5927,7 @@ static u8 bnx2x_8727_read_status(struct bnx2x_phy *phy,
{
struct bnx2x *bp = params->bp;
u8 link_up = 0;
u8 link_up = 0, oc_port = params->port;
u16 link_status = 0;
u16 rx_alarm_status, lasi_ctrl, val1;
@ -5969,8 +5968,10 @@ static u8 bnx2x_8727_read_status(struct bnx2x_phy *phy,
&val1);
if ((val1 & (1<<8)) == 0) {
if (!CHIP_IS_E1x(bp))
oc_port = BP_PATH(bp) + (params->port << 1);
DP(NETIF_MSG_LINK, "8727 Power fault has been detected"
" on port %d\n", params->port);
" on port %d\n", oc_port);
netdev_err(bp->dev, "Error: Power fault on Port %d has"
" been detected and the power to "
"that SFP+ module has been removed"
@ -5978,7 +5979,7 @@ static u8 bnx2x_8727_read_status(struct bnx2x_phy *phy,
" Please remove the SFP+ module and"
" restart the system to clear this"
" error.\n",
params->port);
oc_port);
/* Disable all RX_ALARMs except for mod_abs */
bnx2x_cl45_write(bp, phy,
MDIO_PMA_DEVAD,