iio: 104-quad-8: Fix off-by-one error in register selection
The reset flags operation is selected by bit 2 in the "Reset and Load
Signals Decoders" register, not bit 1.
Fixes: 28e5d3bb03
("iio: 104-quad-8: Add IIO support for the ACCES 104-QUAD-8")
Signed-off-by: William Breathitt Gray <vilhelm.gray@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
3ca24ce9ff
commit
2873c3f0e2
|
@ -138,7 +138,7 @@ static int quad8_write_raw(struct iio_dev *indio_dev,
|
|||
outb(val >> (8 * i), base_offset);
|
||||
|
||||
/* Reset Borrow, Carry, Compare, and Sign flags */
|
||||
outb(0x02, base_offset + 1);
|
||||
outb(0x04, base_offset + 1);
|
||||
/* Reset Error flag */
|
||||
outb(0x06, base_offset + 1);
|
||||
|
||||
|
|