mirror of https://gitee.com/openkylin/linux.git
rtc: ingenic: Reset regulator register in probe
The regulator register specifies how many input clock cycles (minus one) are contained in one tick of the 1 Hz clock. Since this register can contain bogus values after the system boots, it needs to be reset in the probe register, otherwise the RTC may count way to slow or way too fast. Signed-off-by: Paul Cercueil <paul@crapouillou.net> Link: https://lore.kernel.org/r/20200505221336.222313-7-paul@crapouillou.net Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
This commit is contained in:
parent
15eeadd801
commit
378252b6e2
|
@ -372,6 +372,9 @@ static int jz4740_rtc_probe(struct platform_device *pdev)
|
|||
rate = clk_get_rate(clk);
|
||||
jz4740_rtc_set_wakeup_params(rtc, np, rate);
|
||||
|
||||
/* Each 1 Hz pulse should happen after (rate) ticks */
|
||||
jz4740_rtc_reg_write(rtc, JZ_REG_RTC_REGULATOR, rate - 1);
|
||||
|
||||
ret = rtc_register_device(rtc->rtc);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
|
Loading…