of: Add bindings of hw throttle for Tegra soctherm
Add HW throttle configuration sub-node for soctherm, which is used to describe the throttle event, and worked as a cooling device. The "hot" type trip in thermal zone can be bound to this cooling device, and trigger the throttle function. Signed-off-by: Wei Ni <wni@nvidia.com> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This commit is contained in:
parent
c6935931c1
commit
44f3d4170e
|
@ -10,8 +10,14 @@ Required properties :
|
|||
- compatible : For Tegra124, must contain "nvidia,tegra124-soctherm".
|
||||
For Tegra132, must contain "nvidia,tegra132-soctherm".
|
||||
For Tegra210, must contain "nvidia,tegra210-soctherm".
|
||||
- reg : Should contain 1 entry:
|
||||
- reg : Should contain at least 2 entries for each entry in reg-names:
|
||||
- SOCTHERM register set
|
||||
- Tegra CAR register set: Required for Tegra124 and Tegra210.
|
||||
- CCROC register set: Required for Tegra132.
|
||||
- reg-names : Should contain at least 2 entries:
|
||||
- soctherm-reg
|
||||
- car-reg
|
||||
- ccroc-reg
|
||||
- interrupts : Defines the interrupt used by SOCTHERM
|
||||
- clocks : Must contain an entry for each entry in clock-names.
|
||||
See ../clocks/clock-bindings.txt for details.
|
||||
|
@ -25,17 +31,45 @@ Required properties :
|
|||
- #thermal-sensor-cells : Should be 1. See ./thermal.txt for a description
|
||||
of this property. See <dt-bindings/thermal/tegra124-soctherm.h> for a
|
||||
list of valid values when referring to thermal sensors.
|
||||
- throttle-cfgs: A sub-node which is a container of configuration for each
|
||||
hardware throttle events. These events can be set as cooling devices.
|
||||
* throttle events: Sub-nodes must be named as "light" or "heavy".
|
||||
Properties:
|
||||
- nvidia,priority: Each throttles has its own throttle settings, so the
|
||||
SW need to set priorities for various throttle, the HW arbiter can select
|
||||
the final throttle settings.
|
||||
Bigger value indicates higher priority, In general, higher priority
|
||||
translates to lower target frequency. SW needs to ensure that critical
|
||||
thermal alarms are given higher priority, and ensure that there is
|
||||
no race if priority of two vectors is set to the same value.
|
||||
The range of this value is 1~100.
|
||||
- nvidia,cpu-throt-percent: This property is for Tegra124 and Tegra210.
|
||||
It is the throttling depth of pulse skippers, it's the percentage
|
||||
throttling.
|
||||
- nvidia,cpu-throt-level: This property is only for Tegra132, it is the
|
||||
level of pulse skippers, which used to throttle clock frequencies. It
|
||||
indicates cpu clock throttling depth, and the depth can be programmed.
|
||||
Must set as following values:
|
||||
TEGRA_SOCTHERM_THROT_LEVEL_LOW, TEGRA_SOCTHERM_THROT_LEVEL_MED
|
||||
TEGRA_SOCTHERM_THROT_LEVEL_HIGH, TEGRA_SOCTHERM_THROT_LEVEL_NONE
|
||||
- #cooling-cells: Should be 1. This cooling device only support on/off state.
|
||||
See ./thermal.txt for a description of this property.
|
||||
|
||||
Note:
|
||||
- the "critical" type trip points will be set to SOC_THERM hardware as the
|
||||
shut down temperature. Once the temperature of this thermal zone is higher
|
||||
than it, the system will be shutdown or reset by hardware.
|
||||
- the "hot" type trip points will be set to SOC_THERM hardware as the throttle
|
||||
temperature. Once the the temperature of this thermal zone is higher
|
||||
than it, it will trigger the HW throttle event.
|
||||
|
||||
Example :
|
||||
|
||||
soctherm@700e2000 {
|
||||
compatible = "nvidia,tegra124-soctherm";
|
||||
reg = <0x0 0x700e2000 0x0 0x1000>;
|
||||
reg = <0x0 0x700e2000 0x0 0x600 /* SOC_THERM reg_base */
|
||||
0x0 0x60006000 0x0 0x400 /* CAR reg_base */
|
||||
reg-names = "soctherm-reg", "car-reg";
|
||||
interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>;
|
||||
clocks = <&tegra_car TEGRA124_CLK_TSENSOR>,
|
||||
<&tegra_car TEGRA124_CLK_SOC_THERM>;
|
||||
|
@ -44,6 +78,76 @@ Example :
|
|||
reset-names = "soctherm";
|
||||
|
||||
#thermal-sensor-cells = <1>;
|
||||
|
||||
throttle-cfgs {
|
||||
/*
|
||||
* When the "heavy" cooling device triggered,
|
||||
* the HW will skip cpu clock's pulse in 85% depth
|
||||
*/
|
||||
throttle_heavy: heavy {
|
||||
nvidia,priority = <100>;
|
||||
nvidia,cpu-throt-percent = <85>;
|
||||
|
||||
#cooling-cells = <1>;
|
||||
};
|
||||
|
||||
/*
|
||||
* When the "light" cooling device triggered,
|
||||
* the HW will skip cpu clock's pulse in 50% depth
|
||||
*/
|
||||
throttle_light: light {
|
||||
nvidia,priority = <80>;
|
||||
nvidia,cpu-throt-percent = <50>;
|
||||
|
||||
#cooling-cells = <1>;
|
||||
};
|
||||
|
||||
/*
|
||||
* If these two devices are triggered in same time, the HW throttle
|
||||
* arbiter will select the highest priority as the final throttle
|
||||
* settings to skip cpu pulse.
|
||||
*/
|
||||
};
|
||||
};
|
||||
|
||||
Example: referring to Tegra132's "reg", "reg-names" and "throttle-cfgs" :
|
||||
|
||||
soctherm@700e2000 {
|
||||
compatible = "nvidia,tegra132-soctherm";
|
||||
reg = <0x0 0x700e2000 0x0 0x600 /* SOC_THERM reg_base */
|
||||
0x0 0x70040000 0x0 0x200>; /* CCROC reg_base */;
|
||||
reg-names = "soctherm-reg", "ccroc-reg";
|
||||
|
||||
throttle-cfgs {
|
||||
/*
|
||||
* When the "heavy" cooling device triggered,
|
||||
* the HW will skip cpu clock's pulse in HIGH level
|
||||
*/
|
||||
throttle_heavy: heavy {
|
||||
nvidia,priority = <100>;
|
||||
nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>;
|
||||
|
||||
#cooling-cells = <1>;
|
||||
};
|
||||
|
||||
/*
|
||||
* When the "light" cooling device triggered,
|
||||
* the HW will skip cpu clock's pulse in MED level
|
||||
*/
|
||||
throttle_light: light {
|
||||
nvidia,priority = <80>;
|
||||
nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_MED>;
|
||||
|
||||
#cooling-cells = <1>;
|
||||
};
|
||||
|
||||
/*
|
||||
* If these two devices are triggered in same time, the HW throttle
|
||||
* arbiter will select the highest priority as the final throttle
|
||||
* settings to skip cpu pulse.
|
||||
*/
|
||||
|
||||
};
|
||||
};
|
||||
|
||||
Example: referring to thermal sensors :
|
||||
|
@ -62,6 +166,19 @@ Example: referring to thermal sensors :
|
|||
hysteresis = <1000>;
|
||||
type = "critical";
|
||||
};
|
||||
|
||||
cpu_throttle_trip: throttle-trip {
|
||||
temperature = <100000>;
|
||||
hysteresis = <1000>;
|
||||
type = "hot";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_throttle_trip>;
|
||||
cooling-device = <&throttle_heavy 1 1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|
|