regulator: ab8500: Use regulator_list_voltage_linear for fixed voltage

Both ab8500_regulator_mode_ops and ab8500_regulator_ops do not have volt_table
setting, thus we can not use regulator_list_voltage_table for them.
However, they have min_uV setting with n_voltages = 1, so use
regulator_list_voltage_linear instead.

Also remove setting set_voltage_time_sel for ab8500_regulator_mode_ops.
It is used only for fixed voltage, so it does not need to implement
set_voltage_time_sel.

Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Axel Lin 2013-03-25 14:59:00 +08:00 committed by Mark Brown
parent 328a536966
commit 5689e83074
1 changed files with 2 additions and 3 deletions

View File

@ -363,8 +363,7 @@ static struct regulator_ops ab8500_regulator_mode_ops = {
.set_mode = ab8500_regulator_set_mode,
.get_mode = ab8500_regulator_get_mode,
.get_voltage_sel = ab8500_regulator_get_voltage_sel,
.list_voltage = regulator_list_voltage_table,
.set_voltage_time_sel = ab8500_regulator_set_voltage_time_sel,
.list_voltage = regulator_list_voltage_linear,
};
static struct regulator_ops ab8500_regulator_ops = {
@ -372,7 +371,7 @@ static struct regulator_ops ab8500_regulator_ops = {
.disable = ab8500_regulator_disable,
.is_enabled = ab8500_regulator_is_enabled,
.get_voltage_sel = ab8500_regulator_get_voltage_sel,
.list_voltage = regulator_list_voltage_table,
.list_voltage = regulator_list_voltage_linear,
};
static struct ab8500_regulator_info