mirror of https://gitee.com/openkylin/linux.git
regulator: pwm: Document pwm-dutycycle-unit and pwm-dutycycle-range
Document the pwm-dutycycle-unit and pwm-dutycycle-range properties. Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Acked-by: Brian Norris <briannorris@chromium.org> Acked-by: Rob Herring <robh@kernel.org> Acked-by: Mark Brown <broonie@kernel.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This commit is contained in:
parent
ea398e2873
commit
58fd822b2e
|
@ -34,6 +34,18 @@ Only required for Voltage Table Mode:
|
||||||
First cell is voltage in microvolts (uV)
|
First cell is voltage in microvolts (uV)
|
||||||
Second cell is duty-cycle in percent (%)
|
Second cell is duty-cycle in percent (%)
|
||||||
|
|
||||||
|
Optional properties for Continuous mode:
|
||||||
|
- pwm-dutycycle-unit: Integer value encoding the duty cycle unit. If not
|
||||||
|
defined, <100> is assumed, meaning that
|
||||||
|
pwm-dutycycle-range contains values expressed in
|
||||||
|
percent.
|
||||||
|
|
||||||
|
- pwm-dutycycle-range: Should contain 2 entries. The first entry is encoding
|
||||||
|
the dutycycle for regulator-min-microvolt and the
|
||||||
|
second one the dutycycle for regulator-max-microvolt.
|
||||||
|
Duty cycle values are expressed in pwm-dutycycle-unit.
|
||||||
|
If not defined, <0 100> is assumed.
|
||||||
|
|
||||||
NB: To be clear, if voltage-table is provided, then the device will be used
|
NB: To be clear, if voltage-table is provided, then the device will be used
|
||||||
in Voltage Table Mode. If no voltage-table is provided, then the device will
|
in Voltage Table Mode. If no voltage-table is provided, then the device will
|
||||||
be used in Continuous Voltage Mode.
|
be used in Continuous Voltage Mode.
|
||||||
|
@ -53,6 +65,13 @@ Continuous Voltage With Enable GPIO Example:
|
||||||
regulator-min-microvolt = <1016000>;
|
regulator-min-microvolt = <1016000>;
|
||||||
regulator-max-microvolt = <1114000>;
|
regulator-max-microvolt = <1114000>;
|
||||||
regulator-name = "vdd_logic";
|
regulator-name = "vdd_logic";
|
||||||
|
/* unit == per-mille */
|
||||||
|
pwm-dutycycle-unit = <1000>;
|
||||||
|
/*
|
||||||
|
* Inverted PWM logic, and the duty cycle range is limited
|
||||||
|
* to 30%-70%.
|
||||||
|
*/
|
||||||
|
pwm-dutycycle-range <700 300>; /* */
|
||||||
};
|
};
|
||||||
|
|
||||||
Voltage Table Example:
|
Voltage Table Example:
|
||||||
|
|
Loading…
Reference in New Issue