dt-bindings: iio: adc: sd-modulator: fix io-channel-cells

io-channel-cells should be <0> since sigma delta modulator exports only
one channel, as described in ../iio/iio-bindings.txt "IIO providers"
section. Only the phandle is necessary for IIO consumers in this case.

Fixes: af11143757 ("IIO: Add DT bindings for sigma delta adc modulator")

Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
Acked-by: Arnaud Pouliquen <arnaud.pouliquen@st.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Fabrice Gasnier 2018-02-23 12:07:21 +01:00 committed by Jonathan Cameron
parent 0645af1b69
commit 6de2aeb574
1 changed files with 2 additions and 2 deletions

View File

@ -3,11 +3,11 @@ Device-Tree bindings for sigma delta modulator
Required properties:
- compatible: should be "ads1201", "sd-modulator". "sd-modulator" can be use
as a generic SD modulator if modulator not specified in compatible list.
- #io-channel-cells = <1>: See the IIO bindings section "IIO consumers".
- #io-channel-cells = <0>: See the IIO bindings section "IIO consumers".
Example node:
ads1202: adc@0 {
compatible = "sd-modulator";
#io-channel-cells = <1>;
#io-channel-cells = <0>;
};