mirror of https://gitee.com/openkylin/linux.git
drm/amdgpu: check context id for context switching (v2)
check the filp is not robust, and sometimes different contexts may have same filp value. v2: check both filp and ctx_id Signed-off-by: Jammy Zhou <Jammy.Zhou@amd.com> Reviewed-by: Christian König <christian.koenig@amd.com>
This commit is contained in:
parent
66b3cf2ab3
commit
72efa7ebde
|
@ -945,6 +945,7 @@ struct amdgpu_ring {
|
|||
unsigned next_rptr_offs;
|
||||
unsigned fence_offs;
|
||||
struct drm_file *current_filp;
|
||||
unsigned current_ctx;
|
||||
bool need_ctx_switch;
|
||||
enum amdgpu_ring_type type;
|
||||
char name[16];
|
||||
|
|
|
@ -642,8 +642,10 @@ static int amdgpu_cs_ib_fill(struct amdgpu_device *adev,
|
|||
ib->is_const_ib = true;
|
||||
if (chunk_ib->flags & AMDGPU_IB_FLAG_GDS)
|
||||
ib->gds_needed = true;
|
||||
if (ib->ring->current_filp != parser->filp) {
|
||||
if ((ib->ring->current_filp != parser->filp) ||
|
||||
(ib->ring->current_ctx != parser->ctx_id)) {
|
||||
ib->ring->need_ctx_switch = true;
|
||||
ib->ring->current_ctx = parser->ctx_id;
|
||||
ib->ring->current_filp = parser->filp;
|
||||
}
|
||||
|
||||
|
|
Loading…