mirror of https://gitee.com/openkylin/linux.git
net: phy: icplus: use PHY_ID_MATCH_EXACT() for IP101A/G
According to the datasheet of the IP101A/G there is no revision field and MII_PHYSID2 always reads as 0x0c54. Use PHY_ID_MATCH_EXACT() then. Signed-off-by: Michael Walle <michael@walle.cc> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
2ad4758cec
commit
7360a4de36
|
@ -349,7 +349,7 @@ static struct phy_driver icplus_driver[] = {
|
|||
.suspend = genphy_suspend,
|
||||
.resume = genphy_resume,
|
||||
}, {
|
||||
PHY_ID_MATCH_MODEL(IP101A_PHY_ID),
|
||||
PHY_ID_MATCH_EXACT(IP101A_PHY_ID),
|
||||
.name = "ICPlus IP101A/G",
|
||||
/* PHY_BASIC_FEATURES */
|
||||
.probe = ip101a_g_probe,
|
||||
|
@ -365,7 +365,7 @@ module_phy_driver(icplus_driver);
|
|||
static struct mdio_device_id __maybe_unused icplus_tbl[] = {
|
||||
{ PHY_ID_MATCH_MODEL(IP175C_PHY_ID) },
|
||||
{ PHY_ID_MATCH_MODEL(IP1001_PHY_ID) },
|
||||
{ PHY_ID_MATCH_MODEL(IP101A_PHY_ID) },
|
||||
{ PHY_ID_MATCH_EXACT(IP101A_PHY_ID) },
|
||||
{ }
|
||||
};
|
||||
|
||||
|
|
Loading…