mirror of https://gitee.com/openkylin/linux.git
hwmon: (aspeed-pwm-tacho) increase fan tach period
The previous value reduced the time required to determine the fan value, however, it's also used as the final timeout mechanism. The prevous value would work for any fan speed greater than around 3k RPM. This increased value, lets the fan speeds return quickly but will wait longer to handle speeds below 3k RPM. Testing: this value was determined through experimentation on the ast2400 on the Quanta-q71l. This configurations runs 8 fans attached to the controller. Signed-off-by: Patrick Venture <venture@google.com> Reviewed-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
fd53f62160
commit
762b1e8880
|
@ -161,7 +161,7 @@
|
|||
* 11: reserved.
|
||||
*/
|
||||
#define M_TACH_MODE 0x02 /* 10b */
|
||||
#define M_TACH_UNIT 0x00c0
|
||||
#define M_TACH_UNIT 0x0210
|
||||
#define INIT_FAN_CTRL 0xFF
|
||||
|
||||
/* How long we sleep in us while waiting for an RPM result. */
|
||||
|
|
Loading…