mirror of https://gitee.com/openkylin/linux.git
hwmon: (lm75) Fix write operations for negative temperatures
Writes into limit registers fail if the temperature written is negative.
The regmap write operation checks the value range, regmap_write accepts
an unsigned int as parameter, and the temperature value passed to
regmap_write is kept in a variable declared as long. Negative values
are converted large unsigned integers, which fails the range check.
Fix by type casting the temperature to u16 when calling regmap_write().
Cc: Iker Perez del Palomar Sustatxa <iker.perez@codethink.co.uk>
Fixes: e65365fed8
("hwmon: (lm75) Convert to use regmap")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
6f8c8f3c31
commit
7d82fcc9d9
|
@ -154,7 +154,7 @@ static int lm75_write(struct device *dev, enum hwmon_sensor_types type,
|
|||
temp = DIV_ROUND_CLOSEST(temp << (resolution - 8),
|
||||
1000) << (16 - resolution);
|
||||
|
||||
return regmap_write(data->regmap, reg, temp);
|
||||
return regmap_write(data->regmap, reg, (u16)temp);
|
||||
}
|
||||
|
||||
static umode_t lm75_is_visible(const void *data, enum hwmon_sensor_types type,
|
||||
|
|
Loading…
Reference in New Issue