mmc: tmio: enhance illegal sequence handling

An illegal sequence command error may occur if there is a stopbit or
cmd_index error as well as a CRC error. The correct course of action
is to re-enable IRQs

An illegal sequence data error may occur if there is a CRC or stopbit
error,  or underrun. In this case set data->error correctly.

This is in preparation for enabling tuning support which relies on
differentiating between illegal sequence and other errors.

Signed-off-by: Ai Kyuse <ai.kyuse.uw@renesas.com>
[simon: broken out of a larger patch]
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
Acked-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Tested-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
This commit is contained in:
Ai Kyuse 2016-11-03 15:16:00 +01:00 committed by Ulf Hansson
parent c820af5f18
commit 96e0b2ba00
1 changed files with 9 additions and 6 deletions

View File

@ -552,7 +552,7 @@ void tmio_mmc_do_data_irq(struct tmio_mmc_host *host)
schedule_work(&host->done);
}
static void tmio_mmc_data_irq(struct tmio_mmc_host *host)
static void tmio_mmc_data_irq(struct tmio_mmc_host *host, unsigned int stat)
{
struct mmc_data *data;
spin_lock(&host->lock);
@ -561,6 +561,9 @@ static void tmio_mmc_data_irq(struct tmio_mmc_host *host)
if (!data)
goto out;
if (stat & TMIO_STAT_CRCFAIL || stat & TMIO_STAT_STOPBIT_ERR ||
stat & TMIO_STAT_TXUNDERRUN)
data->error = -EILSEQ;
if (host->chan_tx && (data->flags & MMC_DATA_WRITE) && !host->force_pio) {
u32 status = sd_ctrl_read16_and_16_as_32(host, CTL_STATUS);
bool done = false;
@ -609,8 +612,6 @@ static void tmio_mmc_cmd_irq(struct tmio_mmc_host *host,
goto out;
}
host->cmd = NULL;
/* This controller is sicker than the PXA one. Not only do we need to
* drop the top 8 bits of the first response word, we also need to
* modify the order of the response for short response command types.
@ -630,14 +631,16 @@ static void tmio_mmc_cmd_irq(struct tmio_mmc_host *host,
if (stat & TMIO_STAT_CMDTIMEOUT)
cmd->error = -ETIMEDOUT;
else if (stat & TMIO_STAT_CRCFAIL && cmd->flags & MMC_RSP_CRC)
else if ((stat & TMIO_STAT_CRCFAIL && cmd->flags & MMC_RSP_CRC) ||
stat & TMIO_STAT_STOPBIT_ERR ||
stat & TMIO_STAT_CMD_IDX_ERR)
cmd->error = -EILSEQ;
/* If there is data to handle we enable data IRQs here, and
* we will ultimatley finish the request in the data_end handler.
* If theres no data or we encountered an error, finish now.
*/
if (host->data && !cmd->error) {
if (host->data && (!cmd->error || cmd->error == -EILSEQ)) {
if (host->data->flags & MMC_DATA_READ) {
if (host->force_pio || !host->chan_rx)
tmio_mmc_enable_mmc_irqs(host, TMIO_MASK_READOP);
@ -698,7 +701,7 @@ static bool __tmio_mmc_sdcard_irq(struct tmio_mmc_host *host,
/* Data transfer completion */
if (ireg & TMIO_STAT_DATAEND) {
tmio_mmc_ack_mmc_irqs(host, TMIO_STAT_DATAEND);
tmio_mmc_data_irq(host);
tmio_mmc_data_irq(host, status);
return true;
}