i2c: tegra: Don't mark VI I2C as IRQ safe runtime PM

Tegra VI I2C is part of VE power domain and typically used for
camera usecases.

VE power domain is not always on and is non-IRQ safe. So, IRQ safe
device cannot be attached to a non-IRQ safe domain as it prevents
powering off the PM domain and generic power domain driver will warn.

Current driver marks all I2C devices as IRQ safe and VI I2C device
does not require IRQ safe as it will not be used for atomic transfers.

This patch has fix to make VI I2C as non-IRQ safe.

Reviewed-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Sowjanya Komatineni <skomatineni@nvidia.com>
Signed-off-by: Wolfram Sang <wsa@kernel.org>
This commit is contained in:
Sowjanya Komatineni 2020-07-27 13:57:19 -07:00 committed by Wolfram Sang
parent 8682dc1245
commit 9e29420ddb
1 changed files with 9 additions and 1 deletions

View File

@ -1750,7 +1750,15 @@ static int tegra_i2c_probe(struct platform_device *pdev)
goto unprepare_slow_clk;
}
pm_runtime_irq_safe(&pdev->dev);
/*
* VI I2C is in VE power domain which is not always on and not
* an IRQ safe. So, IRQ safe device can't be attached to a non-IRQ
* safe domain as it prevents powering off the PM domain.
* Also, VI I2C device don't need to use runtime IRQ safe as it will
* not be used for atomic transfers.
*/
if (!i2c_dev->is_vi)
pm_runtime_irq_safe(&pdev->dev);
pm_runtime_enable(&pdev->dev);
if (!pm_runtime_enabled(&pdev->dev)) {
ret = tegra_i2c_runtime_resume(&pdev->dev);