mirror of https://gitee.com/openkylin/linux.git
media: ov5640: fix auto controls values when switching to manual mode
When switching from auto to manual mode, V4L2 core is calling g_volatile_ctrl() in manual mode in order to get the manual initial value. Remove the manual mode check/return to not break this behaviour. Signed-off-by: Hugues Fruchet <hugues.fruchet@st.com> Tested-by: Jacopo Mondi <jacopo@jmondi.org> Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com> Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
This commit is contained in:
parent
c2c3f42df4
commit
a8f438c684
|
@ -2334,16 +2334,12 @@ static int ov5640_g_volatile_ctrl(struct v4l2_ctrl *ctrl)
|
|||
|
||||
switch (ctrl->id) {
|
||||
case V4L2_CID_AUTOGAIN:
|
||||
if (!ctrl->val)
|
||||
return 0;
|
||||
val = ov5640_get_gain(sensor);
|
||||
if (val < 0)
|
||||
return val;
|
||||
sensor->ctrls.gain->val = val;
|
||||
break;
|
||||
case V4L2_CID_EXPOSURE_AUTO:
|
||||
if (ctrl->val == V4L2_EXPOSURE_MANUAL)
|
||||
return 0;
|
||||
val = ov5640_get_exposure(sensor);
|
||||
if (val < 0)
|
||||
return val;
|
||||
|
|
Loading…