ARM: dts: ls1021a: fix the value of TMR_FIPER1

The timer fixed interval period pulse generator register
is used to generate periodic pulses. The down count
register loads the value programmed in the fixed period
interval (FIPER). At every tick of the timer accumulator
overflow, the counter decrements by the value of
TMR_CTRL[TCLK_PERIOD]. It generates a pulse when the down
counter value reaches zero. It reloads the down counter
in the cycle following a pulse. To use the TMR_FIPER1
register to generate a 1 PPS event, the value
(10^9 nanoseconds) - TCLK_PERIOD should be programmed.
It should be 999999995 not 999999990 since TCLK_PERIOD
is 5.

Signed-off-by: Yangbo Lu <yangbo.lu@nxp.com>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
This commit is contained in:
Yangbo Lu 2017-11-29 14:54:58 +08:00 committed by Shawn Guo
parent 44eac6ef37
commit bdba5017d1
1 changed files with 1 additions and 1 deletions

View File

@ -589,7 +589,7 @@ ptp_clock@2d10e00 {
fsl,tclk-period = <5>;
fsl,tmr-prsc = <2>;
fsl,tmr-add = <0xaaaaaaab>;
fsl,tmr-fiper1 = <999999990>;
fsl,tmr-fiper1 = <999999995>;
fsl,tmr-fiper2 = <99990>;
fsl,max-adj = <499999999>;
};