mirror of https://gitee.com/openkylin/linux.git
rt2800: validate step value for temperature compensation
Some hardware has correct (!= 0xff) value of tssi_bounds[4] in the EEPROM, but step is equal to 0xff. This results on ridiculous delta calculations and completely broke TX power settings. Reported-and-tested-by: Pavel Lucik <pavel.lucik@gmail.com> Cc: stable@vger.kernel.org Signed-off-by: Stanislaw Gruszka <sgruszka@redhat.com> Acked-by: Ivo van Doorn <IvDoorn@gmail.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
parent
8c6e30936a
commit
bf7e1abe43
|
@ -2449,7 +2449,7 @@ static int rt2800_get_gain_calibration_delta(struct rt2x00_dev *rt2x00dev)
|
||||||
/*
|
/*
|
||||||
* Check if temperature compensation is supported.
|
* Check if temperature compensation is supported.
|
||||||
*/
|
*/
|
||||||
if (tssi_bounds[4] == 0xff)
|
if (tssi_bounds[4] == 0xff || step == 0xff)
|
||||||
return 0;
|
return 0;
|
||||||
|
|
||||||
/*
|
/*
|
||||||
|
|
Loading…
Reference in New Issue