rt2800: validate step value for temperature compensation

Some hardware has correct (!= 0xff) value of tssi_bounds[4] in the
EEPROM, but step is equal to 0xff. This results on ridiculous delta
calculations and completely broke TX power settings.

Reported-and-tested-by: Pavel Lucik <pavel.lucik@gmail.com>
Cc: stable@vger.kernel.org
Signed-off-by: Stanislaw Gruszka <sgruszka@redhat.com>
Acked-by: Ivo van Doorn <IvDoorn@gmail.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Stanislaw Gruszka 2012-10-25 09:51:39 +02:00 committed by John W. Linville
parent 8c6e30936a
commit bf7e1abe43
1 changed files with 1 additions and 1 deletions

View File

@ -2449,7 +2449,7 @@ static int rt2800_get_gain_calibration_delta(struct rt2x00_dev *rt2x00dev)
/* /*
* Check if temperature compensation is supported. * Check if temperature compensation is supported.
*/ */
if (tssi_bounds[4] == 0xff) if (tssi_bounds[4] == 0xff || step == 0xff)
return 0; return 0;
/* /*