mirror of https://gitee.com/openkylin/linux.git
thermal: power_allocator: round the division when divvying up power
In situations where there is an uneven number of cooling devices, the division of power among them can lead to a milliwatt being dropped on the floor due to rounding errors. This doesn't sound like a lot, but some devices only grant the lowest cooling device state for their maximum power. So for instance, if the granted_power is the maximum power and all devices are getting their maximum power, one would get max_power - 1, making it choose cooling device state 1, instead of 0. Round the division to make the calculation more accurate. Cc: Zhang Rui <rui.zhang@intel.com> Cc: Eduardo Valentin <edubezval@gmail.com> Signed-off-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
488c7455d7
commit
ea54cac906
|
@ -196,7 +196,8 @@ static void divvy_up_power(u32 *req_power, u32 *max_power, int num_actors,
|
|||
for (i = 0; i < num_actors; i++) {
|
||||
u64 req_range = req_power[i] * power_range;
|
||||
|
||||
granted_power[i] = div_u64(req_range, total_req_power);
|
||||
granted_power[i] = DIV_ROUND_CLOSEST_ULL(req_range,
|
||||
total_req_power);
|
||||
|
||||
if (granted_power[i] > max_power[i]) {
|
||||
extra_power += granted_power[i] - max_power[i];
|
||||
|
|
Loading…