mirror of https://gitee.com/openkylin/linux.git
regulator: pwm-regulator: Remove obsoleted property
In "[3d7ef30] regulator: pwm-regulator: Simplify voltage to duty-cycle call" we stopped using max_duty_cycle, so we can retire it from device data and DT. There is no need to deprecate this property, as it hasn't hit Mainline yet. Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
a505bfb10a
commit
f747a1fe78
|
@ -29,15 +29,14 @@ Required properties:
|
||||||
|
|
||||||
- pwms: PWM specification (See: ../pwm/pwm.txt)
|
- pwms: PWM specification (See: ../pwm/pwm.txt)
|
||||||
|
|
||||||
One of these must be provided:
|
Only required for Voltage Table Mode:
|
||||||
- voltage-table: Voltage and Duty-Cycle table consisting of 2 cells
|
- voltage-table: Voltage and Duty-Cycle table consisting of 2 cells
|
||||||
First cell is voltage in microvolts (uV)
|
First cell is voltage in microvolts (uV)
|
||||||
Second cell is duty-cycle in percent (%)
|
Second cell is duty-cycle in percent (%)
|
||||||
|
|
||||||
- max-duty-cycle: Maximum Duty-Cycle value -- this will normally be
|
NB: To be clear, if voltage-table is provided, then the device will be used
|
||||||
255 (0xff) for an 8 bit PWM device
|
in Voltage Table Mode. If no voltage-table is provided, then the device will
|
||||||
|
be used in Continuous Voltage Mode.
|
||||||
If both are provided, the current default is voltage-table mode.
|
|
||||||
|
|
||||||
Any property defined as part of the core regulator binding can also be used.
|
Any property defined as part of the core regulator binding can also be used.
|
||||||
(See: ../regulator/regulator.txt)
|
(See: ../regulator/regulator.txt)
|
||||||
|
@ -49,8 +48,6 @@ Continuous Voltage Example:
|
||||||
regulator-min-microvolt = <1016000>;
|
regulator-min-microvolt = <1016000>;
|
||||||
regulator-max-microvolt = <1114000>;
|
regulator-max-microvolt = <1114000>;
|
||||||
regulator-name = "vdd_logic";
|
regulator-name = "vdd_logic";
|
||||||
|
|
||||||
max-duty-cycle = <255>; /* 8bit PWM */
|
|
||||||
};
|
};
|
||||||
|
|
||||||
Voltage Table Example:
|
Voltage Table Example:
|
||||||
|
|
|
@ -30,7 +30,6 @@ struct pwm_regulator_data {
|
||||||
int state;
|
int state;
|
||||||
|
|
||||||
/* Continuous voltage */
|
/* Continuous voltage */
|
||||||
u32 max_duty_cycle;
|
|
||||||
int volt_uV;
|
int volt_uV;
|
||||||
};
|
};
|
||||||
|
|
||||||
|
@ -201,14 +200,6 @@ static int pwm_regulator_init_continuous(struct platform_device *pdev,
|
||||||
struct pwm_regulator_data *drvdata)
|
struct pwm_regulator_data *drvdata)
|
||||||
{
|
{
|
||||||
struct device_node *np = pdev->dev.of_node;
|
struct device_node *np = pdev->dev.of_node;
|
||||||
int ret;
|
|
||||||
|
|
||||||
ret = of_property_read_u32(np, "max-duty-cycle",
|
|
||||||
&drvdata->max_duty_cycle);
|
|
||||||
if (ret) {
|
|
||||||
dev_err(&pdev->dev, "Failed to read \"pwm-max-value\"\n");
|
|
||||||
return ret;
|
|
||||||
}
|
|
||||||
|
|
||||||
pwm_regulator_desc.ops = &pwm_regulator_voltage_continuous_ops;
|
pwm_regulator_desc.ops = &pwm_regulator_voltage_continuous_ops;
|
||||||
pwm_regulator_desc.continuous_voltage_range = true;
|
pwm_regulator_desc.continuous_voltage_range = true;
|
||||||
|
|