mirror of https://gitee.com/openkylin/linux.git
mt7623:
add cooling mask to all CPUs add compatible to sysirq binding -----BEGIN PGP SIGNATURE----- iQJLBAABCAA1FiEEiUuSfQSYnG8EMsBltDliWyzx00MFAlxd1V0XHG1hdHRoaWFz LmJnZ0BnbWFpbC5jb20ACgkQtDliWyzx00OGww/9Fma+4OGoHtgn0z5Z+cfQ//mw oaUxV8C7IxONQAriQ4KPOmyi6AGnvuGu0iuQSmzW+ueDK4HNfU92BuNNBJSyW9PO Vs/nsP6QZJTtpG/aUpmuYrG0iwpk8y1TuLQTQ19Txtnwy5ryaMt3xqU+7v9pPv4j vF8mZ9BUJ6JEX6so5xM1zHZLNvV2y1rQ3rYR9TeUfTAJnH/n4Qme/ZR/3zSICgGO Q++f3w9hXlwEFxQdeYUoQohj41ih9KlgZo1uXOI7QDMMFg8PzIkzj14rDDNsIkRD Yaq3oN3qFx8JzB+mNAa4WWsCHHtqSoLBlr3hc1YKSbn5gCctyJaI4LNuhu2J8WCq YNqk7LesuxwD/Hr5yzuqYL2pJjLA6Bwjw6pyJxQOzZJJ6m2RyuWwmMT0BgcnaU1j 1o7MafEnskbus/to4TQ0Sbq0EkOf7YElABII59/JR42t1779aclQ+KjwQNSB+KkY kssqdCJ6ATKFr+2FCwZN92zi7U4M2NBffJj/jj0t5oEZC0ZZYoq31MEgK6iwzMEP XdOdoOOw8IGxl/RnoQq8bNdX8ca9K5UCw/kSGN6OGwA1bFzfbp3nKEBBdlVpMYqF IMVJRsIFbqx5Xn64gMXhwWByEFCz0jsT1BexDy0K4a0SjC0O7pzWj8zs4xD0H1Y/ XkSPcBe07hOmkdFTA60= =bcQS -----END PGP SIGNATURE----- Merge tag 'v5.0-next-dts32' of git://git.kernel.org/pub/scm/linux/kernel/git/matthias.bgg/linux into arm/dt mt7623: - add cooling mask to all CPUs - add compatible to sysirq binding * tag 'v5.0-next-dts32' of git://git.kernel.org/pub/scm/linux/kernel/git/matthias.bgg/linux: dt-bindings: interrupt-controller: update bindings for MT7623 ARM: dts: mt7623: Add all CPUs in cooling maps Signed-off-by: Arnd Bergmann <arnd@arndb.de>
This commit is contained in:
commit
f7d488be48
|
@ -9,6 +9,7 @@ Required properties:
|
|||
"mediatek,mt8135-sysirq", "mediatek,mt6577-sysirq": for MT8135
|
||||
"mediatek,mt8127-sysirq", "mediatek,mt6577-sysirq": for MT8127
|
||||
"mediatek,mt7622-sysirq", "mediatek,mt6577-sysirq": for MT7622
|
||||
"mediatek,mt7623-sysirq", "mediatek,mt6577-sysirq": for MT7623
|
||||
"mediatek,mt6795-sysirq", "mediatek,mt6577-sysirq": for MT6795
|
||||
"mediatek,mt6797-sysirq", "mediatek,mt6577-sysirq": for MT6797
|
||||
"mediatek,mt6765-sysirq", "mediatek,mt6577-sysirq": for MT6765
|
||||
|
|
|
@ -187,17 +187,26 @@ cpu-crit {
|
|||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_passive>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
|
||||
map1 {
|
||||
trip = <&cpu_active>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
|
||||
map2 {
|
||||
trip = <&cpu_hot>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
|
Loading…
Reference in New Issue