mirror of https://gitee.com/openkylin/linux.git
dt-bindings: mailbox: mtk-gce: fix incorrect mbox-cells value
As the binding documentation says, #mbox-cells must have a value of 2,
but the example use a value 3. The MT8173 device tree correctly use
mbox-cells = <2>. This commit fixes the example.
Fixes: 19d8e335d5
("dt-binding: gce: remove atomic_exec in mboxes property")
Reviewed-by: Matthias Brugger <matthias.bgg@gmail.com>
Signed-off-by: Fabien Parent <fparent@baylibre.com>
Link: https://lore.kernel.org/r/20201018193016.3339045-1-fparent@baylibre.com
Signed-off-by: Rob Herring <robh@kernel.org>
This commit is contained in:
parent
194810f784
commit
f83b03fc72
|
@ -47,7 +47,7 @@ Example:
|
|||
interrupts = <GIC_SPI 135 IRQ_TYPE_LEVEL_LOW>;
|
||||
clocks = <&infracfg CLK_INFRA_GCE>;
|
||||
clock-names = "gce";
|
||||
#mbox-cells = <3>;
|
||||
#mbox-cells = <2>;
|
||||
};
|
||||
|
||||
Example for a client device:
|
||||
|
|
Loading…