It is necessary to clear MC13892_SWITCHERS0_SWxHI bit when set voltage to the
voltage range from 1100000 to 1375000. Leaving MC13892_SWITCHERS0_SWxHI bit
untouched may result in wrong voltage setting.
For example, currently switch voltage from 1400000 to 1300000 will set the
voltage to 1800000 because the HI bit is still set.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@sirena.org.uk>
It's safe to call regulator_unregister() with NULL, thus remove the NULL test
before regulator_unregister() calls.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@sirena.org.uk>
Patch adds device tree probe support for mc13783-regulator driver.
Signed-off-by: Alexander Shiyan <shc_work@mail.ru>
Signed-off-by: Mark Brown <broonie@sirena.org.uk>
This patch adds a warning about incorrect regulators instead of
printing the names of non-information message about the wrong amount.
Signed-off-by: Alexander Shiyan <shc_work@mail.ru>
Signed-off-by: Mark Brown <broonie@sirena.org.uk>
Ensure to unregister all regulators before return error in probe().
The regulator register order depends on the regulator ID pass to
ab3100_regulator_register() function. Thus we need to scan ab3100_regulator_desc
and find the index of successfully registered regulators, or alternatively just
call ab3100_regulators_remove() to unregister all registered regulators.
Since current code uses a static ab3100_regulators table, explicitly set
reg->rdev = NULL after regulator_unregister() call to ensure calling
ab3100_regulators_remove() in the unwind path always work.
Also move ab3100_regulators_remove() to avoid forward declaration.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Both mc13892_sw1 and mc13892_sw voltage table have ascendant voltage list.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
tps65020 ldo1 and ldo2 vsel tables are identical, merge them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This implements device tree support for the AB3100 regulators
driver. The initial settings are moved out of platform data
and into the driver for the device tree case, as it appears
that there is no way to supply this as AUXDATA for an I2C
device. The style and bindings are heavily inspired by
Lee Jones' style for AB8500.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This refactors the AB3100 regulator probe to use regulator IDs
and pass this to a separate registration function. This works
much smoother when migrating to device tree, as we can use a
match table with this regulator ID encoded in the .driver_data.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Current code overrides control1 variable when setting ramp delay bits.
Fix it by just setting ramp_delay bits.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Currently we have a special code in tps80031_ldo_set_voltage_sel() to handle
LDO2 track mode for TPS80031 or TPS80032-ES1.0. The purpose is to address below
issues:
Issue description:
- LDO2 traking mode is enabled
- LDO2 tracks SMPS2 voltage.
- LDO2 automatically switch-off when LDO2_CFG_VOLTAGE is changed to some discrete values (non exhaustive list):
00011001, 00011010, 00011011, 00011100, .
- LDO2 switch-on again when LDO2_CFG_VOLTAGE is changed to other values (non exhaustive list):
00011000, 00010111, .
LDOs have reserved codes. For these codes, LDO is switch-off.
In tracking, LDO2 ref comes from SMPS2.
However LDO2 enable is still gated by LDO2 VSEL decoding.
As a result, in tracking mode LDO2 will be disabled for following code (SMPS VSEL format):
000000 & 100000 (MSB not decoded)
011001 & 111001 (MSB not decoded)
011010 & 111010 (MSB not decoded)
011100 & 111100 (MSB not decoded)
011101 & 111101 (MSB not decoded)
011110 & 111110 (MSB not decoded)
However, current code has below bugs:
1. It uses regulator_list_voltage_linear, so list_voltage() still shows above
invalid selectors have supported voltage.
2. Current code may return -EINVAL in tps80031_ldo_set_voltage_sel() for
supported voltage. This is because when we use regulator_list_voltage_linear
as list_voltage callback, regulator core will default use
regulator_map_voltage_linear(). regulator_map_voltage_linear() has an
assumption that the voltages are linear which is not true for this case.
For example,
when request voltage range is: min_uV=950000 uV && max_uV=1200000 uV
regulator_map_voltage_linear() returns the selector is 29 (0x1D),
set_voltage_sel() returns -EINVAL.
(The selector is in invalid range, 0x19 ~ 0x1f).
In above case, map_voltage() should find the lowest valid voltage within
specific range (selector = 0x20) and set_voltage_sel() should successfully
set the voltage to 987500 uV.
This patch fixes these issues by:
1. Add checking valid setting for LDO2 track mode of TPS80031 or TPS80032-ES1.0
in list_voltage. So it returns -EINVAL for invalid selectors.
2. Implement tps80031_ldo_map_voltage, use regulator_map_voltage_iterate()
to find the lowest voltage within specific range for TPS80031 or
TPS80032-ES1.0. This is required when the voltage map is no longer linear.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Thus use regulator_map_voltage_ascend is more efficient than the default
regulator_map_voltage_iterate.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Some regulators have more than 200 supported voltages.
e.g.
For TPS65910_REG_VDD1 and TPS65910_REG_VDD2:
n_voltages = VDD1_2_NUM_VOLT_FINE * VDD1_2_NUM_VOLT_COARSE
= 73 * 3
= 219
Thus it worth converting to regulator_map_voltage_ascend rather than use
default regulator_map_voltage_iterate.
For consistent, convert all regulators to regulator_map_voltage_ascend.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Thus use regulator_map_voltage_ascend is more efficient than the default
regulator_map_voltage_iterate.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Marek Szyprowski <m.szyprowski@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Thus use regulator_map_voltage_ascend is more efficient than the default
regulator_map_voltage_iterate.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Marek Szyprowski <m.szyprowski@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Simply the [get|set]_voltage_sel implementation by using
regulator_[set|get]_voltage_sel_regmap instead of open coded.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
According to the datasheet[1]
Register 0x06h Description: RmpCtrl (REGISTER ADDRESS: 0x06h Read/Write)
BIT[5..7]:
RMP[2:0] Output voltage ramp timing
D7-D5 Slope
000 32mV/us
001 16mV/us
010 8mV/us
...
110 0.5mV/us
111 0.25mV/us
Thus to get correct ramp_ctrl value, we need to right-shift 5 bits.
[1] http://www.ti.com/lit/ds/symlink/tps62360.pdf
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Datasheet says:
Time Step (TSTEP) selection, when changing the output voltage, the new value is
reached through successive voltage steps (if not bypassed). The equivalent
programmable slew rate of the output voltage is:
TSTEP[1:0]: 00 Jump (no slope control)
TSTEP[1:0]: 01 10mV/us
TSTEP[1:0]: 10 5mV/us (default)
TSTEP[1:0]: 11 2.5mV/us
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The ctrl_addr setting for SMPS10 is missed, thus palmas_smps_init() read/write
wrong register for SMPS10 in current code. Fix it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
SMPS3 and SMPS7 do not have tstep_addr setting, so current code actually
writes 0 to smps12_ctl (offset is 0) register when set_ramp_delay callback
is called for SMPS3 and SMPS7.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
When SMPS45 is set to off and LDO8 tracking is enabled, the output voltage can
be set from 0.45 to 1.65 V. Thus set min_uV to be 450000.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage_shift can be calculated from voltage_mask.
Let's remove voltage_shift fied from struct ab8500_regulator_info, this change
can prevent missing voltage_shift setting issue.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage_shift field of struct expand_register is not used now, remove it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The Palma device like TPS65913 have the mode mask which is also
used for enable/disable the rails. The mode bits are defined as
00: OFF
01: AUTO
10: ECO
11: Forced PWM
and modes are set accordingly as
REGULATOR_MODE_NORMAL: AUTO
REGULATOR_MODE_IDLE: ECO
REGULATOR_MODE_FAST: PWM
Two issue observed:
1. If client calls following sequence:
regulator_enable(),
regulator_set_mode(FAST),
regulator_disable()
and again the regulator_enable() then the mode is reset
to NORMAL inplace of keeping the mode as FAST.
Fixing this by storing the current mode configured by client
and restoring modes when enable() is called after disable().
2. In following sequence, the regulator get enabled:
regulator_disable()
regulator_set_mode(FAST),
Fixing this by updating new mode in register only if it is
enabled.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Currently Palma regulator driver support the ramp delay
through rail specific platform data.
As regulator framework support the configuration of ramp
delay through regulator constraint, using the framework
method and removing the platform specific data approach.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
A lot of regulator hardware has ascendant voltage list.
This patch adds regulator_map_voltage_ascend() and export it.
Drivers that have ascendant voltage list can use this as their map_voltage()
operation, this is more efficient than default regulator_map_voltage_iterate()
function.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
When setting voltage for AB8540_LDO_AUX3, current code only updates one of
info->voltage_reg and info->expand_register registers which is wrong.
To ensure we set to correct voltage, it always needs to clear or set
expand_register.voltage_mask bit of expand_register.
The function of the expand register bit is the following (from the user manual):
0: VAUX3 output voltage is determined by Vaux3Sel bit settings in register
VldoCVaux3Sel
1: VAUX3 output voltage is set to 3.05V regardless of Vaux3Sel settings in
register VldoCVaux3Sel (VldoCVaux3Sel is the register at 0x0421)
So when going to 3.05V, set the expand register bit.
When leaving 3.05V for another voltage, set the target voltage before clearing
the expand register bit.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Both enable() and disable() functions have only one caller, thus remove them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This ensures info->update_val status is still correct if set_mode() call fails.
Otherwise, get_mode() may return wrong status if a set_mode() call fails.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Currently, set invalid mode setting for shared mode regulators may change
sm->lp_mode_req flag. This patch ensures we don't set lp_mode_req flag to wrong
status if set_mode() fails.
This patch includes some clean up, and these changes makes this patch looks like
code refactor. The clean up is mainly to avoid adding ugly code to handle
failure paths.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch ensures info->update_val is consistent with current register value.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
LDO8 of Palma device like tps65913 support the tracking mode
on which LDO8 track the SMPS45 voltage when SMPS45 is ON
and use the LDO8.VOLTAGE_SEL register when SMPS45 is OFF.
On track mode, the steps of voltage change for LDO8 is 25mV
where in non-tracking mode it is 50mV. Set the steps accordingly.
Number of voltage count is still same for both the cases.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Palmas device have control outputs like REGEN1, REGEN2, REGEN3,
SYSEN1 and SYSEN2. These control outputs can be used for controlling
external voltage switches to enabled/disable voltage outputs.
Add support of these control outputs through regulator framework.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Clear the sleep/warm reset bits when it is not selected through
regulator platform data. This will make sure that configuration
is inline with the platform data regardless of boot/POR
configuration.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
commit 6d191a5fc7
(regulator: core: Don't defer probe if there's no DT binding for a supply)
Attempted to differentiate between regulator_get() with an actual
DT binding for the supply and when there is none to avoid unnecessary
deferal.
However, ret value supplied by regulator_dev_lookup() is being
ignored by regulator_get(). So, exit with the appropriate return value.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The same table can be used for multiple instance of pdev, so we don't need to
allocate memory for of_regulator_match table per pdev.
match->driver_data points to the corresponding entry of as3711_reg_info,
however it is not used in current code, thus this patch does not set
driver_data in the of_regulator_match table.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
We can save a register read operation in some case if read
expand_register first.
If info->expand_register.voltage_mask bit is set, no need to read
voltage_reg.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The *dev and *mfd of struct rc5t583_regulator_info are not used after convert
to use regmap, remove them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
GENERIC_GPIO is now equivalent to GPIOLIB and features that depended on
GENERIC_GPIO can now depend on GPIOLIB to allow removal of this option.
Signed-off-by: Alexandre Courbot <acourbot@nvidia.com>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
Acked-by: Grant Likely <grant.likely@secretlab.ca>
pdata is either a valid pointer or NULL, use NULL checking rather than
IS_ERR_OR_NULL macro.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage_mask is 0xc0, thus we need to set voltage_shift = 6 to get correct
selector in get_voltage_sel and set_voltage_sel.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage_mask and voltage_shift settings of AB8505_LDO_AUDIO are not matched.
It looks like a typo in the voltage_mask settings.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Ensure the regulators are registered with a GPIO parsed from the device
tree when available.
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
ab8500_ext_regulator_exit() never fails.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The implementation of ab8500_ext_fixed_get_voltage is identical to
ab8500_ext_list_voltage. We can avoid the duplicate implementation by just
remove get_voltage. For fixed regulator, regulator core will call
list_voltage(rdev, 0) to get voltage if both get_voltage get_voltage_sel are
not implemented.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This code was added by commit 0fe17e20a6
"regulator: ab8500-ext: Add support for AB9540 regulators"
and commit bd44e2cb "regulator: ab8500: Also check for AB8505 based platforms"
The original patch[1] is to set info->desc.ops = &ab9540_ext_regulator_ops.
However, ab9540_ext_regulator_ops is identical to ab8500_ext_regulator_ops[2].
Thus we can complete remove the unnecessary checking for ab9540 and ab8540.
[1] https://lkml.org/lkml/2013/3/28/333
[2] https://lkml.org/lkml/2013/4/1/178
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The intention of this patch is to simplify the code.
Maintain the is_enabled flag is not trivial, it not only needs to set/clear the
flag in disable()/enable() but also needs to set the flag in is_enable() to get
initial status. The only benefit of keeping is_enabled flag is just save a
register read when set_mode(). Remove is_enabled flag makes the code simpler.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The intention of this patch is to simplify the code.
Maintain the is_enabled flag is not trivial, it not only needs to set/clear the
flag in disable()/enable() but also needs to set the flag in is_enable() to get
initial status. The only benefit of keeping is_enabled flag is just save a
register read when set_mode(). Remove is_enabled flag makes the code simpler.
This patch also moves ab8500_regulator_is_enabled() close to
ab8500_regulator_[en|dis]able functions.
This is required to avoid a forward declaration because now we call
ab8500_regulator_is_enabled() in ab8500_regulator_set_mode().
This change also makes the code better in readability by moving similar
functions to one place.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Almost all systems use the regulators on the WM8994 series devices to
provide DCVDD and AVDD1 so if no init data is supplied then set up the
supplies for the user. This simplifies integration of the device into
systems, especially when device tree is supported.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All users of ab8500_regulator_volt_mode_ops and ab8500_regulator_volt_ops
do not set info->desc.enable_time, thus set_voltage_time_sel() always returns 0.
Remove it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch adds Device Tree support to max8952 regulator driver.
Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch modifies platform data structure of max8952 driver to
use pointer to regulator_init_data struct instead of embedding it.
This is a prerequisite for adding Device Tree support for the driver.
Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Regulator drivers may specify regulator_desc->supply_name which
regulator_register() will use to find the supply node for a regulator.
If no supply was specified in the device tree or the supply has yet
to be registered regulator_register() will fail, deferring the probe
of the regulator. In the case where no supply node was specified in the
device tree, there is no supply and it is pointless to try and find one
later, so go ahead and add the regulator without the supply.
Signed-off-by: Andrew Bresticker <abrestic@chromium.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The regulators can only be used to supply the CODEC so we don't need to
worry about users that still need fudges for init ordering issues.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For fixed voltage, we can just set min_uV and use regulator_list_voltage_linear
for list_voltage callback. Regulator core will call list_voltage(rdev, 0) if
both get_voltage get_voltage_sel are not implemented. Thus we can also remove
lp8788_ldo_fixed_get_voltage() function.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Milo Kim <milo.kim@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The id for DLDOx matches the entries in enum lp8788_ldo_id and it's easy to
calculate the id for ALDOx. Thus remove lp8788_dldo_id and lp8788_aldo_id
arrays.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Milo Kim <milo.kim@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This is required for regulator_list_voltage_table() to properly work.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
commit b080c78a4e
"regulator: ab8500: Update voltage handling for fixed voltage regulators"
removes min_uV settings and sets volt_table for all fixed voltages, thus
we can not use regulator_list_voltage_linear now. Use
regulator_list_voltage_table instead.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The ab*_match[] arrays should be moved out of the way, instead of
bunched in the middle of the initialisation functions. This patch
moves all initialisation code which currently resides above these
arrays down to be grouped with the others. This makes the whole
thing slightly easier to read.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The regulator framework offers a generic regulator_list_voltage_table()
function which can directly look-up a regulator's voltage capabilities
using a table provided through the desc structure. This patch ensures
that information is available.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The regulator framework now has provisions to read a regulator's
start-up time via the 'enable_time' attribute. So let's remove all
'enable_time'/'delay' duplication and just stick with 'enable_time'
from now on.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Allow the regulator framework to directly access the time it takes
any given regulator to settle. This saves time and code because
without it we would have to implement a dedication function to read
the value from elsewhere.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Introduce aux5, aux6 into ab8540 regulator framework.
Signed-off-by: Zhenhua HUANG <zhenhua.huang@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Maxime COQUELIN <maxime.coquelin@stericsson.com>
Reviewed-by: David PARIS <david.paris@stericsson.com>
Reviewed-by: Philippe LANGLAIS <philippe.langlais@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
At the probe use a structure to select the good regulator array from
from ab9540, ab8505, ab8540 or ab8500 configuration.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
operating_point is not used since the initial commit of db8500-prcmu driver,
remove it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Add voltage setting for vdmic; add LP mode setting for vamic1,2.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>