Convert the S5PV210/S5P64X0 32-bit down-counting clocksource to
the generic mmio clocksource infrastructure
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
This patch fixes following.
<6>[ 0.000000] sched_clock: 32 bits at 33MHz, ...
<6>[ 128.651309] Calibrating delay loop...
There is a big jump. The reason is that PWM Timer which
is for HRTimer was used before its initialization.
So this patch changes its order and following is kernel
boot log message after this.
<6>[ 0.000000] sched_clock: 32 bits at 33MHz, ...
<6>[ 0.000088] Calibrating delay loop...
Signed-off-by: Sangbeom Kim <sbkim73@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
s5p duplicates the runtime selection of the timer register three times.
Move this out into a separate function.
FIXME: It is unclear whether this code needs to support true runtime
selection of the timer register, or whether it can be selected once at
init time.
Acked-by: Kukjin Kim <kgene.kim@samsung.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
This patch adds support HR-Timer(High Resolution Timer) and dynamic
tick system for S5P SoCs. There are many clock sources for HR-Timer
on S5P SoCs. The PWM timer, RTC, System Timer, and MCT can be used
for clock source.
This patch can only support PWM timer for clock source of S5P64X0
and S5PV210.
Signed-off-by: Sangbeom Kim <sbkim73@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>