CPU frequency tables don't update after the driver is registered and so we don't
need to iterate over them to find total number of states every time
cpufreq_get_max_state() is called. Do it once at boot time.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
get_cpu_frequency() isn't doing much by itself, just calling get_property(). And
so this wrapper isn't required at all. Get rid of it.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
cpufreq_apply_cooling() has a single caller, cpufreq_set_cur_state() and
cpufreq_set_cur_state() is an unnecessary wrapper over cpufreq_apply_cooling().
Get rid of it by merging both routines.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
There is no point checking for validity of 'cpufreq_val' from
cpufreq_thermal_notifier() every time the routine is called. Its guaranteed to
be 0 on the first call but will be valid otherwise.
Lets update it once while the device registers.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This makes life easy and bug free. And is scalable for future resource
allocations.
Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Because get_cpu_frequency() has returned a valid frequency, it means that the
cpufreq policy is surely valid and so no point checking that again with
is_cpufreq_valid(). Get rid of the routine as well as there are no more users.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
All CPUs present in 'allowed_cpus' share the same 'struct cpufreq_policy'
structure and so calling cpufreq_update_policy() for each of them doesn't make
sense.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
In __cpufreq_cooling_register() we try to match min/max frequencies for all CPUs
passed in 'clip_cpus' mask. This mask is the cpumask of cpus where the frequency
constraints will be applied.
Same frequency constraint can be applied only to the CPUs belonging to the same
cluster (i.e. CPUs sharing clock line). For all such CPUs we have a single
'struct cpufreq_policy' structure managing them and so getting policies for all
CPUs wouldn't make any sense as they will all return the same pointer.
So, remove this useless check of checking min/max for all CPUs. Also update doc
comment to make this more obvious that clip_cpus should be same as
policy->related_cpus.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
We aren't supposed to return our own error type here. Return what we got.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
ret is initialized before it is used, so no need to set it to 0 in its declaration.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
It will be overwritten soon with return value of kzalloc().
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This wasn't explained well anywhere and should be clearly specified. Lets add a
top level comment for this.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
cooling_cpufreq_lock isn't used to protect this structure and so the comment
over it is outdated. Fix it.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
In this patch, the cpu_cooling code checks for the usability of cpufreq
layer before proceeding with the CPU cooling device registration. The
main reason is: CPU cooling device is not usable if cpufreq cannot
switch frequencies.
Similar checks are spread in thermal drivers. Thus, the advantage now
is to have the check in a single place: cpu cooling device registration.
For this reason, this patch also updates the existing drivers that
depend on CPU cooling to simply propagate the error code of the cpu
cooling registration call. Therefore, in case cpufreq is not ready, the
thermal drivers will still return -EPROBE_DEFER, in an attempt to try
again when cpufreq layer gets ready.
Cc: devicetree@vger.kernel.org
Cc: Grant Likely <grant.likely@linaro.org>
Cc: Kukjin Kim <kgene.kim@samsung.com>
Cc: linux-arm-kernel@lists.infradead.org
Cc: linux-kernel@vger.kernel.org
Cc: linux-pm@vger.kernel.org
Cc: linux-samsung-soc@vger.kernel.org
Cc: Naveen Krishna Chatradhi <ch.naveen@samsung.com>
Cc: Rob Herring <robh+dt@kernel.org>
Cc: Zhang Rui <rui.zhang@intel.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Existing code updates cupfreq policy only while executing
cpufreq_apply_cooling() function (i.e. when notify_device != NOTIFY_INVALID).
It doesn't apply constraints when cpufreq policy update happens from any other
place but it should update the cpufreq policy with thermal constraints every
time when there is a cpufreq policy update, to keep state of
cpufreq_cooling_device and max_feq of cpufreq policy in sync. For instance
while resuming cpufreq updates cpufreq_policy and it restores default
policy->usr_policy values irrespective of cooling device's cpufreq_state since
notification gets missed because (notify_device == NOTIFY_INVALID).
Another problem, is that userspace is able to change max_freq irrespective of
cooling device's state, as notification gets missed.
This patch modifies code to maintain a global cpufreq_dev_list and applies
constraints of all matching cooling devices for policy's cpu when there is any
policy update(ends up applying the lowest max_freq among the matching cpu
cooling devices).
This patch also removes redundant check (max_freq > policy->user_policy.max),
as cpufreq framework takes care of user_policy constraints already where ever
required, otherwise its causing an issue while increasing max_freq in normal
scenerio as it restores max_freq with policy->user_policy.max which is old
(smaller) value.
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
The cpufreq core now supports the cpufreq_for_each_valid_entry macro
helper for iteration over the cpufreq_frequency_table, so use it.
Also remove the redundant !! operator.
It should have no functional changes.
Signed-off-by: Stratos Karafotis <stratosk@semaphore.gr>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
As per Documentation/thermal/sysfs-api.txt, max_level
is an index, not a counter. Thus, in case a CPU has
3 valid frequencies, max_level is expected to be 2, for instance.
The current code makes max_level == number of valid frequencies,
which is bogus. This patch fix the cpu_cooling device by
ranging max_level properly.
Reported-by: Carlos Hernandez <ceh@ti.com>
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This patch introduces an API to register cpufreq cooling device
based on device tree node.
The registration via device tree node differs from normal
registration due to the fact that it is needed to fill
the device_node structure in order to be able to match
the cooling devices with trip points.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
In case of error, the function thermal_cooling_device_register() returns
ERR_PTR() and never returns NULL. The NULL test in the return value check
should be replaced with IS_ERR().
Signed-off-by: Wei Yongjun <yongjun_wei@trendmicro.com.cn>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This patch avoids NULL pointer accesses while unregistering
cpu cooling devices, in case a NULL pointer is received.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
cpufreq_thermal_notifier() is to change the cpu's cpufreq in the allowed_cpus mask
when associated thermal-cpufreq cdev's cooling state is changed. It's a cpufreq policy
notifier handler and it will be triggered even if those cpus out of allowed_cpus has
changed freq policy.
cpufreq_thermal_notifier() checks the policy->cpu. If it belongs to allowed_cpus,
change max_freq(default to 0) to the desire cpufreq value and pass 0 and max_freq
to cpufreq_verify_within_limits() as cpufreq scope. But if not, do nothing and
max_freq will remain 0. This will cause the cpufreq scope to become 0~0. This
is not right. This patch is to return directly after finding cpu not belonging
to allowed_cpus.
Signed-off-by: Lan Tianyu <tianyu.lan@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
The variable 'descend' is initialized as -1 in function get_property(),
and will never get any chance to be updated by the following code.
if (freq != CPUFREQ_ENTRY_INVALID && descend != -1)
descend = !!(freq > table[i].frequency);
This makes function get_property() return the wrong frequency for given
cooling level if the frequency table is sorted in ascending. Fix it
by correcting the 'descend' check in if-condition to 'descend == -1'.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Improve code readiness by changing alignments so that
they match open parenthesis, like checkpatch.pl --strict
suggests.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
There are at least three patterns for oneline comments in this
file. This patch changes them to one single pattern
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Just for code readiness, this patch makes all functions
on this file to have a blank line before their returns.
Now, some functions follow this pattern, and others will
not have a blank line. So, this patch makes it a single
pattern.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
The list is not needed so far. Thus removing it.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Just for style purposes, remove extra curl brackets.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Limit the amount of bytes written to dev_name by
secure writing with snprintf.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Update comments for this exported function.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Add proper documentation for exported function cpufreq_cooling_register.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Update kernel-doc comment and documentation for cpufreq_thermal_notifier.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Add documentation for cpufreq_get_cooling_level. As this
is an exported function, it has to be documented.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
As this is one of the central functions of this file,
it deserves a proper documentation. This patch improves
the existing comment to format it as a kernel-doc style.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Update documentation for is_cpufreq_valid function so
that kernel-doc does not complain about return value.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
level will be used only if GET_FREQ mode is requested.
There is no potential harm with current code. But for
cleaning the compilation log, this patch initializes
level to zero.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Restrict the usage to GPL modules.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Simple fixes for making kernel_doc happy about
struct cpufreq_cooling_device. Includes also a minor
spelling fix.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This code doesn't work on big endian systems because we're storing low
values in the high bits of the unsigned long. It makes it a very high
value instead.
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
cpufreq cooling uses different frequencies as different cooling states.
But the per_cpu cpufreq_frequency_table may contain duplicate,
invalid entries, and it may be in either ascending or descending order.
And currently, code for parsing the per_cpu cpufreq_frequency_table
is used in several places and inconsistent.
Now introduce new code to
1. get the maximum cooling states
2. translate cooling state to cpu frequency
3. translate cpu frequency to cooling state
in one place,
with the correct logic of handling per_cpu cpufreq_frequency_table.
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Tested-by: Amit Daniel kachhap <amit.daniel@samsung.com>
Pull thermal management updates from Zhang Rui:
"Highlights:
- introduction of Dove thermal sensor driver.
- introduction of Kirkwood thermal sensor driver.
- introduction of intel_powerclamp thermal cooling device driver.
- add interrupt and DT support for rcar thermal driver.
- add thermal emulation support which allows platform thermal driver
to do software/hardware emulation for thermal issues."
* 'release' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (36 commits)
thermal: rcar: remove __devinitconst
thermal: return an error on failure to register thermal class
Thermal: rename thermal governor Kconfig option to avoid generic naming
thermal: exynos: Use the new thermal trend type for quick cooling action.
Thermal: exynos: Add support for temperature falling interrupt.
Thermal: Dove: Add Themal sensor support for Dove.
thermal: Add support for the thermal sensor on Kirkwood SoCs
thermal: rcar: add Device Tree support
thermal: rcar: remove machine_power_off() from rcar_thermal_notify()
thermal: rcar: add interrupt support
thermal: rcar: add read/write functions for common/priv data
thermal: rcar: multi channel support
thermal: rcar: use mutex lock instead of spin lock
thermal: rcar: enable CPCTL to use hardware TSC deciding
thermal: rcar: use parenthesis on macro
Thermal: fix a build warning when CONFIG_THERMAL_EMULATION cleared
Thermal: fix a wrong comment
thermal: sysfs: Add a new sysfs node emul_temp for thermal emulation
PM: intel_powerclamp: off by one in start_power_clamp()
thermal: exynos: Miscellaneous fixes to support falling threshold interrupt
...
Convert to the much saner new idr interface.
Signed-off-by: Tejun Heo <tj@kernel.org>
Cc: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
"level" parameter of get_cpu_frequency equals cooling state
of cpu cooling device, and it starts from 0.
Fix the misleading comment.
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
There are predefined cpu_masks that are const data structures.
This patch changes the cpu cooling register function so that
those const cpu_masks can be used, without compilation warnings.
include/linux/cpumask.h
* The following particular system cpumasks and operations manage
* possible, present, active and online cpus.
*
* cpu_possible_mask- has bit 'cpu' set iff cpu is populatable
* cpu_present_mask - has bit 'cpu' set iff cpu is populated
* cpu_online_mask - has bit 'cpu' set iff cpu available to scheduler
* cpu_active_mask - has bit 'cpu' set iff cpu available to migration
*
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Silences the following sparse warning:
drivers/thermal/cpu_cooling.c:67:31: warning:
symbol 'notify_device' was not declared. Should it be static?
Signed-off-by: Sachin Kamat <sachin.kamat@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Problem of using this list is that the cpufreq_get_max_state callback will be
called when register cooling device by thermal_cooling_device_register, but
this list isn't ready at this moment. What's more, there is no need to maintain
such a list, we can get cpufreq_cooling_device instance by the private
thermal_cooling_device.devdata.
Signed-off-by: hongbo.zhang <hongbo.zhang@linaro.com>
Reviewed-by: Francesco Lavra <francescolavra.fl@gmail.com>
Reviewed-by: Amit Daniel Kachhap <amit.kachhap@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
In the while loop for counting cpu frequencies, if table[i].frequency equals
CPUFREQ_ENTRY_INVALID, index i won't be increased, so this leads to an endless
loop, what's more the index i cannot be referred as cpu frequencies number if
there is CPUFREQ_ENTRY_INVALID case.
Signed-off-by: hongbo.zhang <hongbo.zhang@linaro.com>
Reviewed-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Amit Daniel Kachhap <amit.kachhap@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
The curly bracket should be aligned with corresponding if else statements.
Signed-off-by: hongbo.zhang <hongbo.zhang@linaro.com>
Reviewed-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Conflicts:
drivers/staging/omap-thermal/omap-thermal-common.
OMAP supplied dummy TC1 and TC2,
at the same time that the thermal tree removed them
from thermal_zone_device_register()
drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
propogate the upstream MAX_IDR_LEVEL re-name
to prevent a build failure
Previously-fixed-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: Len Brown <len.brown@intel.com>
This patch fixes small bug on cpu_cooling. CPU cooling device has own
id generated with idr mathod. However in the previous version, it swapped
to all same id at last stage of probing as 0. This makes id's collision and
also occures error when it releases that id.
Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
This patchset introduces a new generic cooling device based on cpufreq
that can be used on non-ACPI platforms. As a proof of concept, we have
drivers for the following platforms using this mechanism now:
* Samsung Exynos (Exynos4 and Exynos5) in the current patchset.
* Freescale i.MX (git://git.linaro.org/people/amitdanielk/linux.git imx6q_thermal)
There is a small change in cpufreq cooling registration APIs, so a minor
change is needed for Freescale platforms.
Brief Description:
1) The generic cooling devices code is placed inside driver/thermal/*
as placing inside acpi folder will need un-necessary enabling of acpi
code. This code is architecture independent.
2) This patchset adds generic cpu cooling low level implementation
through frequency clipping. In future, other cpu related cooling
devices may be added here. An ACPI version of this already exists
(drivers/acpi/processor_thermal.c) .But this will be useful for
platforms like ARM using the generic thermal interface along with the
generic cpu cooling devices. The cooling device registration API's
return cooling device pointers which can be easily binded with the
thermal zone trip points. The important APIs exposed are,
a) struct thermal_cooling_device *cpufreq_cooling_register(
struct cpumask *clip_cpus)
b) void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
3) Samsung exynos platform thermal implementation is done using the
generic cpu cooling APIs and the new trip type. The temperature sensor
driver present in the hwmon folder(registered as hwmon driver) is moved
to thermal folder and registered as a thermal driver.
A simple data/control flow diagrams is shown below,
Core Linux thermal <-----> Exynos thermal interface <----- Temperature Sensor
| |
\|/ |
Cpufreq cooling device <---------------
TODO:
*Will send the DT enablement patches later after the driver is merged.
This patch:
Add support for generic cpu thermal cooling low level implementations
using frequency scaling up/down based on the registration parameters.
Different cpu related cooling devices can be registered by the user and
the binding of these cooling devices to the corresponding trip points can
be easily done as the registration APIs return the cooling device pointer.
The user of these APIs are responsible for passing clipping frequency .
The drivers can also register to recieve notification about any cooling
action called.
[akpm@linux-foundation.org: fix comment layout]
Signed-off-by: Amit Daniel Kachhap <amit.kachhap@linaro.org>
Cc: Guenter Roeck <guenter.roeck@ericsson.com>
Cc: SangWook Ju <sw.ju@samsung.com>
Cc: Durgadoss <durgadoss.r@intel.com>
Cc: Len Brown <lenb@kernel.org>
Cc: Jean Delvare <khali@linux-fr.org>
Cc: Kyungmin Park <kmpark@infradead.org>
Cc: Kukjin Kim <kgene.kim@samsung.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>