It is a bit confusing how CEC_CAP_RC and IS_REACHABLE(CONFIG_RC_CORE)
interact. By stripping CEC_CAP_RC at the beginning rather than after #else
it should be a bit clearer what is going on.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Reported-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Currently when the RC Core is enabled (reachable) core code located
in cec_register_adapter() attempts to populate the RC structure with
a pointer to the 'parent' passed in by the caller.
Unfortunately if the caller did not specify RC capability when calling
cec_allocate_adapter(), then there will be no RC structure to populate.
This causes a "NULL pointer dereference" error.
Fixes: f51e80804f ("[media] cec: pass parent device in register(), not allocate()")
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Cc: <stable@vger.kernel.org> # for v4.10 and up
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Support the CEC notifier framework, simplifying drivers that
depend on this.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Tested-by: Marek Szyprowski <m.szyprowski@samsung.com>
Tested-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Acked-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Feature Abort shouldn't be sent in reply to messages from Unregistered,
since that would make it a broadcast message.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
When validating the struct cec_s_log_addrs input a debug message is printed
for all except two of the 'return -EINVAL' paths.
Also log the reason for the missing two paths.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Several error paths didn't log why an error was returned. Add this.
Also handle the corner case of "adapter is unconfigured AND the message
is from Unregistered to TV AND reply is non-zero" separately and return
EINVAL in that case, since it really is an invalid value and not an
unconfigured CEC device.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The hardcoded function name is actually wrong. Use __func__ instead.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The CEC_TRANSMIT ioctl now returns -EPERM if an attempt is made to
transmit a message for an unconfigured adapter (i.e. userspace
never called CEC_ADAP_S_LOG_ADDRS).
This differentiates this case from when LAs are configured, but no
physical address is set. In that case -ENONET is returned.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The CEC specifications explicitly allows you to send poll messages and
Image/Text View On messages to a TV, even when unconfigured (i.e. there is
no hotplug signal detected). Some TVs will pull the HPD low when switching
to another input, or when going into standby, but CEC should still be
allowed to wake up such a display.
Add support for sending messages with initiator 0xf (Unregistered) and
destination 0 (TV) when no physical address is present.
This also required another change: the CEC adapter has to stay enabled as
long as 1) the CEC device is configured or 2) at least one filehandle is open
for the CEC device.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
When the adapter is unloaded or unconfigured, then all transmits and
pending waits should be flushed.
Move this code into its own function and improve the code that cancels
delayed work to avoid having to unlock adap->lock.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
-----BEGIN PGP SIGNATURE-----
iQEcBAABAgAGBQJYqh1gAAoJEHm+PkMAQRiGMlYH/A1GkDfcx5wmdc6wuMit2vim
O/8aGsq2m+TyfjNmMR51nXroZaziW/zTtOyiBgaEEK9HAuEJhd1omq6TvLbeIoF2
QBQKUsu06jsxtYazm91XOCHBHy0uKunkSsv+NmAWBOGVtkja3pzn+qAFsfqNAx5Y
CTwNR1/fasA8OgXMRyhC3dcatY2iwXkVZ7BSut0Umcug3D69V8GbCDjqZg5hmlD2
v8yk7i58CtKezKK9pBHAE5qQyFTl5T77paLB49sLZ9PQU33uafSOm8spxzO4Z1Is
8QyHyUtdcJStRCPeOgOlFGjB+WpOKHXDA1LjshhC0P9U6AmU+hR0X5wSx8dp1s4=
=Tjmr
-----END PGP SIGNATURE-----
Merge tag 'v4.10' into patchwork
Linux 4.10
* tag 'v4.10': (1558 commits)
Linux 4.10
Fix missing sanity check in /dev/sg
scsi: don't BUG_ON() empty DMA transfers
ipv6: release dst on error in ip6_dst_lookup_tail
printk: use rcuidle console tracepoint
ARM: multi_v7_defconfig: enable Qualcomm RPMCC
irda: Fix lockdep annotations in hashbin_delete().
vxlan: fix oops in dev_fill_metadata_dst
dccp: fix freeing skb too early for IPV6_RECVPKTINFO
dpaa_eth: small leak on error
packet: Do not call fanout_release from atomic contexts
reset: fix shared reset triggered_count decrement on error
ntb: ntb_hw_intel: link_poll isn't clearing the pending status properly
ntb_transport: Pick an unused queue
ntb: ntb_perf missing dmaengine_unmap_put
NTB: ntb_transport: fix debugfs_remove_recursive
Revert "nohz: Fix collision between tick and other hrtimers"
vfs: fix uninitialized flags in splice_to_pipe()
drm/radeon: Use mode h/vdisplay fields to hide out of bounds HW cursor
ARM: 8658/1: uaccess: fix zeroing of 64-bit get_user()
...
Poll messages that are used to allocate a logical address should
use the same initiator as the destination. Instead, it expected that
the initiator was 0xf which is not according to the standard.
This also had consequences for the message checks in cec_transmit_msg_fh
that incorrectly rejected poll messages with the same initiator and
destination.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The driver type can be assigned immediately when an RC device
requests to the framework to allocate the device.
This is an 'enum rc_driver_type' data type and specifies whether
the device is a raw receiver or scancode receiver. The type will
be given as parameter to the rc_allocate_device device.
Change accordingly all the drivers calling rc_allocate_device()
so that the device type is specified during the rc device
allocation. Whenever the device type is not specified, it will be
set as RC_DRIVER_SCANCODE which was the default '0' value.
Suggested-by: Sean Young <sean@mess.org>
Signed-off-by: Andi Shyti <andi.shyti@samsung.com>
Signed-off-by: Sean Young <sean@mess.org>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Due to an incorrect condition the last_la used for the initial attempt at
claiming a logical address could be wrong.
The last_la wasn't converted to a mask when ANDing with type2mask, so that
test was broken.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
This race was discovered by running cec-compliance -A with the cec module debug
parameter set to 2: suddenly the test would fail.
It turns out that this happens when the test configures the adapter in
non-blocking mode, then it waits for the CEC_EVENT_STATE_CHANGE event and once
the event is received it unconfigures the adapter.
What happened was that the unconfigure was executed while the configure was
still transmitting the Report Features and Report Physical Address messages.
This messed up the internal state of the cec_adapter.
The fix is to transmit those messages with the adap->lock mutex held (this will
just queue them up in the internal transmit queue, and not actually transmit
anything yet). Only unlock the mutex once everything is done. The main thread
will dequeue the messages from the internal transmit queue and transmit them
one by one, unless an unconfigure was done, and in that case any messages are
just dropped.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
It's only a small function and this makes it easier to switch to
transmitting the message with adap->lock held in the next patch.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The fill function just fills in the cec_msg struct, it doesn't transmit
the message. This is now done explicitly.
This makes it possible to switch to transmitting this message with adap->lock
held.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The loop that sets the unused logical addresses to INVALID should be
done before 'configured' is set to true. This ensures that cec_log_addrs
is consistent before it will be used.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
This is a 2.0 only message, so it should return Feature Abort if the
adapter is configured for CEC version 1.4.
Right now it does nothing, which means that the sender will time out.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
When a pending message was canceled (e.g. due to a timeout), then the
old tx_status info was overwritten instead of ORed. The same happened
with the tx_error_cnt field. So just modify them instead of overwriting
them.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
In the (very) small print of the REPORT_CURRENT_LATENCY message there is a
line that says that the last byte of the message (audio out delay) is only
present if the 'audio out compensated' value is 3.
I missed this, and so if this message was sent with a total length of 6 (i.e.
without the audio out delay byte), then it was rejected by the framework
since a minimum length of 7 was expected.
Fix this minimum length check and update the wrappers in cec-funcs.h to do
the right thing based on the message length.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The cec_allocate_adapter function doesn't need the parent device, only the
cec_register_adapter function needs it.
Drop the cec_devnode parent field, since devnode.dev.parent can be used
instead.
This change makes the framework consistent with other frameworks where the
parent device is not used until the device is registered.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Some CEC adapters will receive messages that they initiated. Add a
check that will ignore such messages.
Most hardware behaves correctly in this respect, but I have seen
adapters that don't, so just filter this out in the framework.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Make sure the TX counters are zeroed in the cec_msg struct.
Non-zero TX counters make no sense when a message is received,
and applications should not see non-zero values here.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
An inner for-loop reused the outer loop variable. This was
only noticeable with CEC adapters supporting more than one
logical address.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The CEC_MSG_FL_REPLY_TO_FOLLOWERS message flag only makes sense for transmitted
messages where you want to wait for the reply.
Clear the flag in all other cases.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The last open issues have been addressed, so it is time to move
this out of staging and into the mainline and to move the public
cec headers to include/uapi/linux.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>