Commit Graph

6 Commits

Author SHA1 Message Date
Jonathan Cameron 59b9bb0abc iio:chemical:sps30 Supress some switch fallthrough warnings.
Fixes warnings reported on linux-next but marking one path
and adding an explicit return in the other.

Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Cc: Andreas Brauchli <a.brauchli@elementarea.net>
Acked-by: Tomasz Duszynski <tduszyns@gmail.com>
2019-02-11 20:07:51 +00:00
Dan Carpenter 905889b4a3 iio: chemical: sps30: fix a loop timeout test
The "while (tries--) {" loop is a postop so it exits with "tries" set
to -1.

Fixes: 232e0f6dde ("iio: chemical: add support for Sensirion SPS30 sensor")
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-02-09 18:46:02 +00:00
Tomasz Duszynski 3fa30bf700 iio: chemical: sps30: remove printk format specifier
pr_fmt is used by printk wrappers. There are not any in the driver
code so remove the format specifier.

Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-02-02 17:08:06 +00:00
Tomasz Duszynski 62129a0849 iio: chemical: sps30: allow changing self cleaning period
Sensor can periodically trigger self cleaning. Period can be changed by
writing a new value to a dedicated attribute. Upon attribute read
current period gets returned.

Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-19 17:56:34 +00:00
Tomasz Duszynski c546d49656 iio: chemical: sps30: add support for self cleaning
Self cleaning is especially useful in cases where sensor undergoes
frequent power on/off cycles. In such scenarios it is recommended to
turn self cleaning at least once per week in order to maintain reliable
measurements.

Self cleaning is activated by writing 1 to a dedicated attribute.
Internal fan accelerates to its maximum speed and keeps spinning
for about 10 seconds blowing out accumulated dust.

Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Tested-by: Andreas Brauchli <andreas.brauchli@sensirion.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-05 16:10:39 +00:00
Tomasz Duszynski 232e0f6dde iio: chemical: add support for Sensirion SPS30 sensor
Add support for Sensirion SPS30 particulate matter sensor.

Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-16 14:05:58 +00:00