This patch adds the function can_free_echo_skb to the CAN
device interface to allow upcoming drivers to release echo
skb's in case of error.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The generic packet receive code takes care of setting
netdev->last_rx when necessary, for the sake of the
bonding ARP monitor.
Signed-off-by: Eric Dumazet <eric.dumazet@gmail.com>
Acked-by: Neil Horman <nhorman@txudriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In a couple of cases collapse some extra code like:
int retval = NETDEV_TX_OK;
...
return retval;
into
return NETDEV_TX_OK;
Signed-off-by: Stephen Hemminger <shemminger@vyatta.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
These are all drivers that don't touch real hardware.
Signed-off-by: Stephen Hemminger <shemminger@vyatta.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
For 'real' hardware CAN devices the netlink interface is used to set CAN
specific communication parameters. Real CAN hardware can not be created with
the ip tool ...
The invocation of 'ip link add type can' lead to an oops as the standard rtnl
newlink function was called:
http://bugzilla.kernel.org/show_bug.cgi?id=13954
This patch adds a private newlink function for the CAN device driver interface
that unconditionally returns -EOPNOTSUPP.
Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net>
Reported-by: Dmitry Eremin-Solenikov <dbaryshkov@gmail.com>
CC: Patrick McHardy <kaber@trash.net>
CC: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds support to the ems_pci driver for the new, v2,
4 channel CPC-PCI/PCIe/104P CAN cards from EMS Dr. Thomas Wuensche.
Signed-off-by: Sebastian Haas <haas@ems-wuensche.com>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch fixes a problem when a device is stopped while in the
bus-off state. Then the carrier remains off forever.
Signed-off-by: Kurt Van Dijck <kurt.van.dijck@skynet.be>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If dev_alloc_skb() failed in can_restart(), the device was left behind
in the bus-off state. This patch restarts the device nevertheless.
Signed-off-by: Kurt Van Dijck <kurt.van.dijck@eia.be>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Remove duplicated #include('s) in
drivers/net/can/sja1000/sja1000.c
Signed-off-by: Huang Weiyi <weiyi.huang@gmail.com>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch is the result of an automatic spatch transformation to convert
all ndo_start_xmit() return values of 0 to NETDEV_TX_OK.
Some occurences are missed by the automatic conversion, those will be
handled in a seperate patch.
Signed-off-by: Patrick McHardy <kaber@trash.net>
Signed-off-by: David S. Miller <davem@davemloft.net>
Fixes this compile error on s390:
drivers/net/can/sja1000/sja1000_platform.c: In function 'sp_read_reg':
drivers/net/can/sja1000/sja1000_platform.c:42: error: implicit declaration of function 'ioread8'
drivers/net/can/sja1000/sja1000_platform.c: In function 'sp_write_reg':
drivers/net/can/sja1000/sja1000_platform.c:47: error: implicit declaration of function 'iowrite8'
drivers/net/can/sja1000/sja1000_platform.c: In function 'sp_probe':
drivers/net/can/sja1000/sja1000_platform.c:79: error: implicit declaration of function 'ioremap_nocache'
Cc: Wolfgang Grandegger <wg@grandegger.com>
Cc: Oliver Hartkopp <oliver.hartkopp@volkswagen.de>
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
According to "Documentation/printk-formats.txt", if the type is
dependent on a config option for its size, like resource_size_t,
we should use a format specifier of its largest possible type and
explicitly cast to it.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds a generic driver for SJA1000 chips on the OpenFirmware
platform bus found on embedded PowerPC systems. You need a SJA1000 node
definition in your flattened device tree source (DTS) file similar to:
can@3,100 {
compatible = "nxp,sja1000";
reg = <3 0x100 0x80>;
interrupts = <2 0>;
interrupt-parent = <&mpic>;
nxp,external-clock-frequency = <16000000>;
};
See also Documentation/powerpc/dts-bindings/can/sja1000.txt.
CC: devicetree-discuss@ozlabs.org
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
As discussed on the netdev mailing list, the member "base_addr" of
"struct net_device" should not be (mis)used to store the virtual
address to the SJA1000 register area. According to David Miller,
it's only use is to allow ISA and similar primitive bus devices to
have their I/O ports changed via ifconfig. The virtual address is
now stored in the private data structure of the SJA1000 device and
the callback functions use "struct sja1000_priv" instead of the
unneeded "struct net_device".
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch fixes a few errors sneaked into the initial version of the
device driver interface.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Per Dalen <per.dalen@cnw.se>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The patch adds support for the one or two channel CPC-PCI and CPC-PCIe
cards from EMS Dr. Thomas Wuensche (http://www.ems-wuensche.de).
Signed-off-by: Sebastian Haas <haas@ems-wuensche.com>
Signed-off-by: Markus Plessing <plessing@ems-wuensche.com>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This driver adds support for the SJA1000 chips connected to the
"platform bus", which can be found on various embedded systems.
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: Oliver Hartkopp <oliver.hartkopp@volkswagen.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds the generic Socket-CAN driver for the Philips SJA1000
full CAN controller.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Oliver Hartkopp <oliver.hartkopp@volkswagen.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
The CAN network device driver interface provides a generic interface to
setup, configure and monitor CAN network devices. It exports a set of
common data structures and functions, which all real CAN network device
drivers should use. Please have a look to the SJA1000 or MSCAN driver
to understand how to use them. The name of the module is can-dev.ko.
Furthermore, it adds a Netlink interface allowing to configure the CAN
device using the program "ip" from the iproute2 utility suite.
For further information please check "Documentation/networking/can.txt"
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Oliver Hartkopp <oliver.hartkopp@volkswagen.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds the virtual CAN bus (vcan) network driver.
The vcan device is just a loopback device for CAN frames, no
real CAN hardware is involved.
Signed-off-by: Oliver Hartkopp <oliver.hartkopp@volkswagen.de>
Signed-off-by: Urs Thuermann <urs.thuermann@volkswagen.de>
Signed-off-by: David S. Miller <davem@davemloft.net>