Get rid of users of of_platform_driver in drivers/spi. The
of_platform_{,un}register_driver functions are going away, so the
users need to be converted to using the platform_bus_type directly.
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
Or else we can't operate on the right address when the trans length
is greater than 65535.
Signed-off-by: Mingkai Hu <Mingkai.hu@freescale.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
The user must read N bytes of SPIRF (1 <= N <= 4) that do not exceed the
amount of data in the receive FIFO, so read the SPIRF byte by byte when
the data in receive FIFO is less than 4 bytes.
On Simics, when read N bytes that exceed the amount of data in receive
FIFO, we can't read the data out, that is we can't clear the rx FIFO,
then the CPU will loop on the espi rx interrupt.
Signed-off-by: Mingkai Hu <Mingkai.hu@freescale.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
Add eSPI controller support based on the library code spi_fsl_lib.c.
The eSPI controller is newer controller 85xx/Pxxx devices supported.
There're some differences comparing to the SPI controller:
1. Has different register map and different bit definition
So leave the code operated the register to the driver code, not
the common code.
2. Support 4 dedicated chip selects
The software can't controll the chip selects directly, The SPCOM[CS]
field is used to select which chip selects is used, and the
SPCOM[TRANLEN] field is set to tell the controller how long the CS
signal need to be asserted. So the driver doesn't need the chipselect
related function when transfering data, just set corresponding register
fields to controll the chipseclect.
3. Different Transmit/Receive FIFO access register behavior
For SPI controller, the Tx/Rx FIFO access register can hold only
one character regardless of the character length, but for eSPI
controller, the register can hold 4 or 2 characters according to
the character lengths. Access the Tx/Rx FIFO access register of the
eSPI controller will shift out/in 4/2 characters one time. For SPI
subsystem, the command and data are put into different transfers, so
we need to combine all the transfers to one transfer in order to pass
the transfer to eSPI controller.
4. The max transaction length limitation
The max transaction length one time is limitted by the SPCOM[TRANSLEN]
field which is 0xFFFF. When used mkfs.ext2 command to create ext2
filesystem on the flash, the read length will exceed the max value of
the SPCOM[TRANSLEN] field.
Signed-off-by: Mingkai Hu <Mingkai.hu@freescale.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>