Logan Gunthorpe 5a1c269f15 NTB: switchtec: Move structure definitions into a common header
Create the switchtec.h header in include/linux with hardware defines
and the switchtec_dev structure. Both moved directly from switchtec.c.
This is a prep patch for creating an NTB driver for Switchtec.

Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Reviewed-by: Stephen Bates <sbates@raithlin.com>
Reviewed-by: Kurt Schwemmer <kurt.schwemmer@microsemi.com>
Acked-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Acked-by: Bjorn Helgaas <bhelgaas@google.com>
Signed-off-by: Jon Mason <jdmason@kudzu.us>
2017-11-18 20:37:11 -05:00
Bjorn Helgaas c781f85bc1 Merge branch 'pci/switchtec' into next
* pci/switchtec:
  switchtec: Add device IDs for additional Switchtec products
  switchtec: Add "running" status flag to fw partition info ioctl
2017-07-02 18:51:10 -05:00
Logan Gunthorpe 393958d0d9 switchtec: Add device IDs for additional Switchtec products
The switchtec driver also supports the PAX, PFXL and PFXI products which
have the same management interface.

Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
Reviewed-by: Kurt Schwemmer <kurt.schwemmer@microsemi.com>
2017-06-27 18:25:06 -05:00
Logan Gunthorpe 079e3bc588 switchtec: Add "running" status flag to fw partition info ioctl
This flag lets userspace know which firmware partitions are currently in
use as opposed to just active.  "Active" means they will be in use for the
next reboot, whereas "running" means they are currently in use.

If an old kernel is in use, or the firmware doesn't support these fields,
the new flag will not be set in the output.

Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
Reviewed-by: Kurt Schwemmer <kurt.schwemmer@microsemi.com>
2017-06-27 18:23:14 -05:00
Logan Gunthorpe 9871e9bb5c switchtec: Fix minor bug with partition ID register
When a switch endpoint is configured without NTB, the mmio_ntb registers
will read all zeros.  However, in corner case configurations where the
partition ID is not zero and NTB is not enabled, the code will have the
wrong partition ID and this causes the driver to use the wrong set of
drivers.  To fix this we simply take the partition ID from the system info
region.

Reported-by: Dingbao Chen <dingbao.chen@microsemi.com>
Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
2017-05-22 16:52:30 -05:00
Logan Gunthorpe e40cf640b8 switchtec: Use new cdev_device_add() helper function
Convert from "cdev_add() + device_add()" to cdev_device_add(), and from
"device_del() + cdev_del()" to cdev_device_del().

[bhelgaas: changelog]
Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
2017-05-22 16:52:24 -05:00
Logan Gunthorpe 52eabba5bc switchtec: Add IOCTLs to the Switchtec driver
Add a couple of special IOCTLs to:

* Inform userspace of firmware partition locations
* Pass event counts and allow userspace to wait on events
* Translate PFF numbers used by the switch to port numbers

[Dan Carpenter <dan.carpenter@oracle.com>: fix off-by-one in
ioctl_event_ctl()]
Tested-by: Krishna Dhulipala <krishnad@fb.com>
Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Stephen Bates <stephen.bates@microsemi.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
Reviewed-by: Wei Zhang <wzhang@fb.com>
Reviewed-by: Jens Axboe <axboe@fb.com>
2017-04-12 12:23:37 -05:00
Logan Gunthorpe 5d8e1881f4 switchtec: Add sysfs attributes to the Switchtec driver
Add a few read-only sysfs attributes which provide some device information
that is exposed from the devices, primarily component and device names and
versions.

These are documented in Documentation/ABI/testing/sysfs-class-switchtec.

Tested-by: Krishna Dhulipala <krishnad@fb.com>
Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Stephen Bates <stephen.bates@microsemi.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
Reviewed-by: Wei Zhang <wzhang@fb.com>
Reviewed-by: Jens Axboe <axboe@fb.com>
Reviewed-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-04-12 12:23:37 -05:00
Logan Gunthorpe 080b47def5 MicroSemi Switchtec management interface driver
Microsemi's "Switchtec" line of PCI switch devices is already well
supported by the kernel with standard PCI switch drivers.  However, the
Switchtec device advertises a special management endpoint with a separate
PCI function address and class code.  This endpoint enables some additional
functionality which includes:

 * Packet and Byte Counters
 * Switch Firmware Upgrades
 * Event and Error logs
 * Querying port link status
 * Custom user firmware commands

Add a switchtec kernel module which provides PCI driver that exposes a char
device.  The char device provides userspace access to this interface
through read, write and (optionally) poll calls.

A userspace tool and library which utilizes this interface is available
at [1].  This tool takes inspiration (and borrows some code) from
nvme-cli [2].  The tool is largely complete at this time but additional
features may be added in the future.

[1] https://github.com/sbates130272/switchtec-user
[2] https://github.com/linux-nvme/nvme-cli

[Dan Carpenter <dan.carpenter@oracle.com>: don't invert error codes]
[Christophe JAILLET <christophe.jaillet@wanadoo.fr>: fix
switchtec_dev_open() error handling]
Tested-by: Krishna Dhulipala <krishnad@fb.com>
Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Stephen Bates <stephen.bates@microsemi.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
Reviewed-by: Wei Zhang <wzhang@fb.com>
Reviewed-by: Jens Axboe <axboe@fb.com>
Reviewed-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-03-06 18:33:34 -06:00