Commit Graph

39 Commits

Author SHA1 Message Date
Ursula Braun d70bf4f7a9 net/smc: determine proposed ISM devices
SMCD Version 2 allows to propose up to 8 additional ISM devices
offered to the peer as candidates for SMCD communication.
This patch covers determination of the ISM devices to be proposed.
ISM devices without PNETID are preferred, since ISM devices with
PNETID are a V1 leftover and will disappear over the time.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-09-28 15:19:03 -07:00
Ursula Braun e888a2e833 net/smc: introduce list of pnetids for Ethernet devices
SMCD version 2 allows usage of ISM devices with hardware PNETID
only, if an Ethernet net_device exists with the same hardware PNETID.
This requires to maintain a list of pnetids belonging to
Ethernet net_devices, which is covered by this patch.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-09-28 15:19:03 -07:00
Ursula Braun 3fc6493761 net/smc: prepare for more proposed ISM devices
SMCD Version 2 allows proposing of up to 8 ISM devices in addition
to the native ISM device of SMCD Version 1.
This patch prepares the struct smc_init_info to deal with these
additional 8 ISM devices.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-09-28 15:19:02 -07:00
Karsten Graul a304e29a24 net/smc: remove constant and introduce helper to check for a pnet id
Use the existing symbol _S instead of SMC_ASCII_BLANK, and introduce a
helper to check if a pnetid is set. No functional change.

Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-09-28 15:19:02 -07:00
Ursula Braun 7b2977d083 net/smc: improve server ISM device determination
Move check whether peer can be reached into smc_pnet_find_ism_by_pnetid().
Thus searching continues for another ism device, if check fails.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-09-10 15:24:26 -07:00
Ursula Braun 82087c0330 net/smc: switch smcd_dev_list spinlock to mutex
The similar smc_ib_devices spinlock has been converted to a mutex.
Protecting the smcd_dev_list by a mutex is possible as well. This
patch converts the smcd_dev_list spinlock to a mutex.

Fixes: c6ba7c9ba4 ("net/smc: add base infrastructure for SMC-D and ISM")
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-07-08 12:35:15 -07:00
Ursula Braun 92f3cb0e11 net/smc: fix sleep bug in smc_pnet_find_roce_resource()
Tests showed this BUG:
[572555.252867] BUG: sleeping function called from invalid context at kernel/locking/mutex.c:935
[572555.252876] in_atomic(): 1, irqs_disabled(): 0, non_block: 0, pid: 131031, name: smcapp
[572555.252879] INFO: lockdep is turned off.
[572555.252883] CPU: 1 PID: 131031 Comm: smcapp Tainted: G           O      5.7.0-rc3uschi+ #356
[572555.252885] Hardware name: IBM 3906 M03 703 (LPAR)
[572555.252887] Call Trace:
[572555.252896]  [<00000000ac364554>] show_stack+0x94/0xe8
[572555.252901]  [<00000000aca1f400>] dump_stack+0xa0/0xe0
[572555.252906]  [<00000000ac3c8c10>] ___might_sleep+0x260/0x280
[572555.252910]  [<00000000acdc0c98>] __mutex_lock+0x48/0x940
[572555.252912]  [<00000000acdc15c2>] mutex_lock_nested+0x32/0x40
[572555.252975]  [<000003ff801762d0>] mlx5_lag_get_roce_netdev+0x30/0xc0 [mlx5_core]
[572555.252996]  [<000003ff801fb3aa>] mlx5_ib_get_netdev+0x3a/0xe0 [mlx5_ib]
[572555.253007]  [<000003ff80063848>] smc_pnet_find_roce_resource+0x1d8/0x310 [smc]
[572555.253011]  [<000003ff800602f0>] __smc_connect+0x1f0/0x3e0 [smc]
[572555.253015]  [<000003ff80060634>] smc_connect+0x154/0x190 [smc]
[572555.253022]  [<00000000acbed8d4>] __sys_connect+0x94/0xd0
[572555.253025]  [<00000000acbef620>] __s390x_sys_socketcall+0x170/0x360
[572555.253028]  [<00000000acdc6800>] system_call+0x298/0x2b8
[572555.253030] INFO: lockdep is turned off.

Function smc_pnet_find_rdma_dev() might be called from
smc_pnet_find_roce_resource(). It holds the smc_ib_devices list
spinlock while calling infiniband op get_netdev(). At least for mlx5
the get_netdev operation wants mutex serialization, which conflicts
with the smc_ib_devices spinlock.
This patch switches the smc_ib_devices spinlock into a mutex to
allow sleeping when calling get_netdev().

Fixes: a4cf0443c4 ("smc: introduce SMC as an IB-client")
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-07-08 12:35:15 -07:00
Dmitry Vyukov 09d0310f07 net/smc: mark smc_pnet_policy as const
Netlink policies are generally declared as const.
This is safer and prevents potential bugs.

Signed-off-by: Dmitry Vyukov <dvyukov@google.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-05-26 20:19:13 -07:00
Karsten Graul 0a99be434d net/smc: log important pnetid and state change events
Print to system log when SMC links are available or go down, link group
state changes or pnetids are applied to and removed from devices.
The log entries are triggered by either user configuration actions or
adapter activation/deactivation events and are not expected to happen
often. The entries help SMC users to keep track of the SMC link group
status and to detect when actions are needed (like to add replacements
for failed adapters).

Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-05-05 12:56:52 -07:00
Karsten Graul 6c868a3edc net/smc: introduce smc_pnet_find_alt_roce()
Introduce a new function in smc_pnet.c that searches for an alternate
IB device, using an existing link group and a primary IB device. The
alternate IB device needs to be active and must have the same PNETID
as the link group.

Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-05-01 16:20:05 -07:00
Karsten Graul fdff704dc6 net/smc: rework pnet table to support SMC-R failover
The pnet table stored pnet ids in the smc device structures. When a
device is going down its smc device structure is freed, and when the
device is brought online again it no longer has a pnet id set.
Rework the pnet table implementation to store the device name with their
assigned pnet id and apply the pnet id to devices when they are
registered.

Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-04-29 12:26:32 -07:00
Hans Wippel 29237d22bc net/smc: allow unprivileged users to read pnet table
The current flags of the SMC_PNET_GET command only allow privileged
users to retrieve entries from the pnet table via netlink. The content
of the pnet table may be useful for all users though, e.g., for
debugging smc connection problems.

This patch removes the GENL_ADMIN_PERM flag so that unprivileged users
can read the pnet table.

Signed-off-by: Hans Wippel <ndev@hwipl.net>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-01-21 11:39:56 +01:00
David S. Miller 14684b9301 Merge git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net
One conflict in the BPF samples Makefile, some fixes in 'net' whilst
we were converting over to Makefile.target rules in 'net-next'.

Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-09 11:04:37 -08:00
Ursula Braun 98f3375505 net/smc: fix ethernet interface refcounting
If a pnet table entry is to be added mentioning a valid ethernet
interface, but an invalid infiniband or ISM device, the dev_put()
operation for the ethernet interface is called twice, resulting
in a negative refcount for the ethernet interface, which disables
removal of such a network interface.

This patch removes one of the dev_put() calls.

Fixes: 890a2cb4a9 ("net/smc: rework pnet table")
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-06 17:44:32 -08:00
David S. Miller d31e95585c Merge git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net
The only slightly tricky merge conflict was the netdevsim because the
mutex locking fix overlapped a lot of driver reload reorganization.

The rest were (relatively) trivial in nature.

Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-02 13:54:56 -07:00
Taehee Yoo f3b0a18bb6 net: remove unnecessary variables and callback
This patch removes variables and callback these are related to the nested
device structure.
devices that can be nested have their own nest_level variable that
represents the depth of nested devices.
In the previous patch, new {lower/upper}_level variables are added and
they replace old private nest_level variable.
So, this patch removes all 'nest_level' variables.

In order to avoid lockdep warning, ->ndo_get_lock_subclass() was added
to get lockdep subclass value, which is actually lower nested depth value.
But now, they use the dynamic lockdep key to avoid lockdep warning instead
of the subclass.
So, this patch removes ->ndo_get_lock_subclass() callback.

Signed-off-by: Taehee Yoo <ap420073@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-10-24 14:53:49 -07:00
Ursula Braun c3d9494e68 net/smc: no new connections on disappearing devices
Add a "going_away" indication to ISM devices and IB ports and
avoid creation of new connections on such disappearing devices.

And do not handle ISM events if ISM device is disappearing.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
2019-10-09 19:45:44 -07:00
Johannes Berg ef6243acb4 genetlink: optionally validate strictly/dumps
Add options to strictly validate messages and dump messages,
sometimes perhaps validating dump messages non-strictly may
be required, so add an option for that as well.

Since none of this can really be applied to existing commands,
set the options everwhere using the following spatch:

    @@
    identifier ops;
    expression X;
    @@
    struct genl_ops ops[] = {
    ...,
     {
            .cmd = X,
    +       .validate = GENL_DONT_VALIDATE_STRICT | GENL_DONT_VALIDATE_DUMP,
            ...
     },
    ...
    };

For new commands one should just not copy the .validate 'opt-out'
flags and thus get strict validation.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-04-27 17:07:22 -04:00
David S. Miller 6b0a7f84ea Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/net
Conflict resolution of af_smc.c from Stephen Rothwell.

Signed-off-by: David S. Miller <davem@davemloft.net>
2019-04-17 11:26:25 -07:00
Karsten Graul bc36d2fc93 net/smc: consolidate function parameters
During initialization of an SMC socket a lot of function parameters need
to get passed down the function call path. Consolidate the parameters
in a helper struct so there are less enough parameters to get all passed
by register.

Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-04-12 10:50:56 -07:00
Karsten Graul 8ef659f1a8 net/smc: fix return code from FLUSH command
The FLUSH command is used to empty the pnet table. No return code is
expected from the command. Commit a9d8b0b1e3d6 added namespace support
for the pnet table and changed the FLUSH command processing to call
smc_pnet_remove_by_pnetid() to remove the pnet entries. This function
returns -ENOENT when no entry was deleted, which is now the return code
of the FLUSH command. As a result the FLUSH command will return an error
when the pnet table is already empty.
Restore the expected behavior and let FLUSH always return 0.

Fixes: a9d8b0b1e3d6 ("net/smc: add pnet table namespace support")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-04-11 11:04:08 -07:00
Johannes Berg 3b0f31f2b8 genetlink: make policy common to family
Since maxattr is common, the policy can't really differ sanely,
so make it common as well.

The only user that did in fact manage to make a non-common policy
is taskstats, which has to be really careful about it (since it's
still using a common maxattr!). This is no longer supported, but
we can fake it using pre_doit.

This reduces the size of e.g. nl80211.o (which has lots of commands):

   text	   data	    bss	    dec	    hex	filename
 398745	  14323	   2240	 415308	  6564c	net/wireless/nl80211.o (before)
 397913	  14331	   2240	 414484	  65314	net/wireless/nl80211.o (after)
--------------------------------
   -832      +8       0    -824

Which is obviously just 8 bytes for each command, and an added 8
bytes for the new policy pointer. I'm not sure why the ops list is
counted as .text though.

Most of the code transformations were done using the following spatch:
    @ops@
    identifier OPS;
    expression POLICY;
    @@
    struct genl_ops OPS[] = {
    ...,
     {
    -	.policy = POLICY,
     },
    ...
    };

    @@
    identifier ops.OPS;
    expression ops.POLICY;
    identifier fam;
    expression M;
    @@
    struct genl_family fam = {
            .ops = OPS,
            .maxattr = M,
    +       .policy = POLICY,
            ...
    };

This also gets rid of devlink_nl_cmd_region_read_dumpit() accessing
the cb->data as ops, which we want to change in a later genl patch.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-03-22 10:38:23 -04:00
Ursula Braun 54903572c2 net/smc: allow pnetid-less configuration
Without hardware pnetid support there must currently be a pnet
table configured to determine the IB device port to be used for SMC
RDMA traffic. This patch enables a setup without pnet table, if
the used handshake interface belongs already to a RoCE port.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-02-28 12:49:44 -08:00
Hans Wippel af5f60c7e3 net/smc: allow PCI IDs as ib device names in the pnet table
SMC-D devices are identified by their PCI IDs in the pnet table. In
order to make usage of the pnet table more consistent for users, this
patch adds this form of identification for ib devices as well.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-02-21 10:34:37 -08:00
Hans Wippel 64e28b52c7 net/smc: add pnet table namespace support
This patch adds namespace support to the pnet table code. Each network
namespace gets its own pnet table. Infiniband and smcd device pnetids
can only be modified in the initial namespace. In other namespaces they
can still be used as if they were set by the underlying hardware.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-02-21 10:34:37 -08:00
Hans Wippel f3d74b2245 net/smc: add smcd support to the pnet table
Currently, users can only set pnetids for netdevs and ib devices in the
pnet table. This patch adds support for smcd devices to the pnet table.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-02-21 10:34:37 -08:00
Hans Wippel 890a2cb4a9 net/smc: rework pnet table
If a device does not have a pnetid, users can set a temporary pnetid for
said device in the pnet table. This patch reworks the pnet table to make
it more flexible. Multiple entries with the same pnetid but differing
devices are now allowed. Additionally, the netlink interface now sends
each mapping from pnetid to device separately to the user while
maintaining the message format existing applications might expect. Also,
the SMC data structure for ib devices already has a pnetid attribute.
So, it is used to store the user defined pnetids. As a result, the pnet
table entries are only used for netdevs.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-02-21 10:34:37 -08:00
Hans Wippel ca8dc1334a net/smc: allow 16 byte pnetids in netlink policy
Currently, users can only send pnetids with a maximum length of 15 bytes
over the SMC netlink interface although the maximum pnetid length is 16
bytes. This patch changes the SMC netlink policy to accept 16 byte
pnetids.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-02-01 14:45:44 -08:00
Johannes Berg 56ce3c5a50 smc: generic netlink family should be __ro_after_init
The generic netlink family is only initialized during module init,
so it should be __ro_after_init like all other generic netlink
families.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-09-20 07:49:55 -07:00
Ursula Braun 7005ada68d net/smc: use correct vlan gid of RoCE device
SMC code uses the base gid for VLAN traffic. The gids exchanged in
the CLC handshake and the gid index used for the QP have to switch
from the base gid to the appropriate vlan gid.

When searching for a matching IB device port for a certain vlan
device, it does not make sense to return an IB device port, which
is not enabled for the used vlan_id. Add another check whether a
vlan gid exists for a certain IB device port.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-07-25 22:25:53 -07:00
Hans Wippel 1619f77058 net/smc: add pnetid support for SMC-D and ISM
SMC-D relies on PNETIDs to find usable SMC-D/ISM devices for a SMC
connection. This patch adds SMC-D/ISM support to the current PNETID
implementation.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Suggested-by: Thomas Richter <tmricht@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-30 20:42:25 +09:00
Ursula Braun 0afff91c6f net/smc: add pnetid support
s390 hardware supports the definition of a so-call Physical NETwork
IDentifier (short PNETID) per network device port. These PNETIDS
can be used to identify network devices that are attached to the same
physical network (broadcast domain).

On s390 try to use the PNETID of the ethernet device port used for
initial connecting, and derive the IB device port used for SMC RDMA
traffic.

On platforms without PNETID support fall back to the existing
solution of a configured pnet table.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-30 20:42:25 +09:00
Ursula Braun be6a3f38ff net/smc: determine port attributes independent from pnet table
For SMC it is important to know the current port state of RoCE devices.
Monitoring port states has been triggered, when a RoCE device was added
to the pnet table. To support future alternatives to the pnet table the
monitoring of ports is made independent of the existence of a pnet table.
It starts once the smc_ib_device is established.

Due to this change smc_ib_remember_port_attr() is now a local function
and shuffling its location and the location of its used functions
makes any forward references obsolete.

And the duplicate SMC_MAX_PORTS definition is removed.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-30 20:42:25 +09:00
Eric Biggers d49baa7e12 net/smc: check for missing nlattrs in SMC_PNETID messages
It's possible to crash the kernel in several different ways by sending
messages to the SMC_PNETID generic netlink family that are missing the
expected attributes:

- Missing SMC_PNETID_NAME => null pointer dereference when comparing
  names.
- Missing SMC_PNETID_ETHNAME => null pointer dereference accessing
  smc_pnetentry::ndev.
- Missing SMC_PNETID_IBNAME => null pointer dereference accessing
  smc_pnetentry::smcibdev.
- Missing SMC_PNETID_IBPORT => out of bounds array access to
  smc_ib_device::pattr[-1].

Fix it by validating that all expected attributes are present and that
SMC_PNETID_IBPORT is nonzero.

Reported-by: syzbot+5cd61039dc9b8bfa6e47@syzkaller.appspotmail.com
Fixes: 6812baabf2 ("smc: establish pnet table management")
Cc: <stable@vger.kernel.org> # v4.11+
Signed-off-by: Eric Biggers <ebiggers@google.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-05-14 16:40:45 -04:00
Greg Kroah-Hartman b24413180f License cleanup: add SPDX GPL-2.0 license identifier to files with no license
Many source files in the tree are missing licensing information, which
makes it harder for compliance tools to determine the correct license.

By default all files without license information are under the default
license of the kernel, which is GPL version 2.

Update the files which contain no license information with the 'GPL-2.0'
SPDX license identifier.  The SPDX identifier is a legally binding
shorthand, which can be used instead of the full boiler plate text.

This patch is based on work done by Thomas Gleixner and Kate Stewart and
Philippe Ombredanne.

How this work was done:

Patches were generated and checked against linux-4.14-rc6 for a subset of
the use cases:
 - file had no licensing information it it.
 - file was a */uapi/* one with no licensing information in it,
 - file was a */uapi/* one with existing licensing information,

Further patches will be generated in subsequent months to fix up cases
where non-standard license headers were used, and references to license
had to be inferred by heuristics based on keywords.

The analysis to determine which SPDX License Identifier to be applied to
a file was done in a spreadsheet of side by side results from of the
output of two independent scanners (ScanCode & Windriver) producing SPDX
tag:value files created by Philippe Ombredanne.  Philippe prepared the
base worksheet, and did an initial spot review of a few 1000 files.

The 4.13 kernel was the starting point of the analysis with 60,537 files
assessed.  Kate Stewart did a file by file comparison of the scanner
results in the spreadsheet to determine which SPDX license identifier(s)
to be applied to the file. She confirmed any determination that was not
immediately clear with lawyers working with the Linux Foundation.

Criteria used to select files for SPDX license identifier tagging was:
 - Files considered eligible had to be source code files.
 - Make and config files were included as candidates if they contained >5
   lines of source
 - File already had some variant of a license header in it (even if <5
   lines).

All documentation files were explicitly excluded.

The following heuristics were used to determine which SPDX license
identifiers to apply.

 - when both scanners couldn't find any license traces, file was
   considered to have no license information in it, and the top level
   COPYING file license applied.

   For non */uapi/* files that summary was:

   SPDX license identifier                            # files
   ---------------------------------------------------|-------
   GPL-2.0                                              11139

   and resulted in the first patch in this series.

   If that file was a */uapi/* path one, it was "GPL-2.0 WITH
   Linux-syscall-note" otherwise it was "GPL-2.0".  Results of that was:

   SPDX license identifier                            # files
   ---------------------------------------------------|-------
   GPL-2.0 WITH Linux-syscall-note                        930

   and resulted in the second patch in this series.

 - if a file had some form of licensing information in it, and was one
   of the */uapi/* ones, it was denoted with the Linux-syscall-note if
   any GPL family license was found in the file or had no licensing in
   it (per prior point).  Results summary:

   SPDX license identifier                            # files
   ---------------------------------------------------|------
   GPL-2.0 WITH Linux-syscall-note                       270
   GPL-2.0+ WITH Linux-syscall-note                      169
   ((GPL-2.0 WITH Linux-syscall-note) OR BSD-2-Clause)    21
   ((GPL-2.0 WITH Linux-syscall-note) OR BSD-3-Clause)    17
   LGPL-2.1+ WITH Linux-syscall-note                      15
   GPL-1.0+ WITH Linux-syscall-note                       14
   ((GPL-2.0+ WITH Linux-syscall-note) OR BSD-3-Clause)    5
   LGPL-2.0+ WITH Linux-syscall-note                       4
   LGPL-2.1 WITH Linux-syscall-note                        3
   ((GPL-2.0 WITH Linux-syscall-note) OR MIT)              3
   ((GPL-2.0 WITH Linux-syscall-note) AND MIT)             1

   and that resulted in the third patch in this series.

 - when the two scanners agreed on the detected license(s), that became
   the concluded license(s).

 - when there was disagreement between the two scanners (one detected a
   license but the other didn't, or they both detected different
   licenses) a manual inspection of the file occurred.

 - In most cases a manual inspection of the information in the file
   resulted in a clear resolution of the license that should apply (and
   which scanner probably needed to revisit its heuristics).

 - When it was not immediately clear, the license identifier was
   confirmed with lawyers working with the Linux Foundation.

 - If there was any question as to the appropriate license identifier,
   the file was flagged for further research and to be revisited later
   in time.

In total, over 70 hours of logged manual review was done on the
spreadsheet to determine the SPDX license identifiers to apply to the
source files by Kate, Philippe, Thomas and, in some cases, confirmation
by lawyers working with the Linux Foundation.

Kate also obtained a third independent scan of the 4.13 code base from
FOSSology, and compared selected files where the other two scanners
disagreed against that SPDX file, to see if there was new insights.  The
Windriver scanner is based on an older version of FOSSology in part, so
they are related.

Thomas did random spot checks in about 500 files from the spreadsheets
for the uapi headers and agreed with SPDX license identifier in the
files he inspected. For the non-uapi files Thomas did random spot checks
in about 15000 files.

In initial set of patches against 4.14-rc6, 3 files were found to have
copy/paste license identifier errors, and have been fixed to reflect the
correct identifier.

Additionally Philippe spent 10 hours this week doing a detailed manual
inspection and review of the 12,461 patched files from the initial patch
version early this week with:
 - a full scancode scan run, collecting the matched texts, detected
   license ids and scores
 - reviewing anything where there was a license detected (about 500+
   files) to ensure that the applied SPDX license was correct
 - reviewing anything where there was no detection but the patch license
   was not GPL-2.0 WITH Linux-syscall-note to ensure that the applied
   SPDX license was correct

This produced a worksheet with 20 files needing minor correction.  This
worksheet was then exported into 3 different .csv files for the
different types of files to be modified.

These .csv files were then reviewed by Greg.  Thomas wrote a script to
parse the csv files and add the proper SPDX tag to the file, in the
format that the file expected.  This script was further refined by Greg
based on the output to detect more types of files automatically and to
distinguish between header and source .c files (which need different
comment types.)  Finally Greg ran the script using the .csv files to
generate the patches.

Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Reviewed-by: Philippe Ombredanne <pombredanne@nexb.com>
Reviewed-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-11-02 11:10:55 +01:00
Ursula Braun a6832c3acd net/smc: adjust net_device refcount
smc_pnet_fill_entry() uses dev_get_by_name() adding a refcount to ndev.
The following smc_pnet_enter() has to reduce the refcount if the entry
to be added exists already in the pnet table.

Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-09-21 15:31:02 -07:00
Ursula Braun 5da7e4d355 net/smc: return active RoCE port only
SMC requires an active ib port on the RoCE device.
smc_pnet_find_roce_resource() determines the matching RoCE device port
according to the configured PNET table. Do not return the found
RoCE device port, if it is not flagged active.

Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com>
Reviewed-by: Thomas Richter <tmricht@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-04-11 23:01:14 -04:00
Ursula Braun 249633a443 net/smc: remove useless smc_ib_devices_list check
The global event handler is created only, if the ib_device has already
been used by at least one link group. It is guaranteed that there exists
the corresponding entry in the smc_ib_devices list. Get rid of this
superfluous check.

Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com>
Reviewed-by: Thomas Richter <tmricht@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-04-11 23:01:14 -04:00
Thomas Richter 6812baabf2 smc: establish pnet table management
Connection creation with SMC-R starts through an internal
TCP-connection. The Ethernet interface for this TCP-connection is not
restricted to the Ethernet interface of a RoCE device. Any existing
Ethernet interface belonging to the same physical net can be used, as
long as there is a defined relation between the Ethernet interface and
some RoCE devices. This relation is defined with the help of an
identification string called "Physical Net ID" or short "pnet ID".
Information about defined pnet IDs and their related Ethernet
interfaces and RoCE devices is stored in the SMC-R pnet table.

A pnet table entry consists of the identifying pnet ID and the
associated network and IB device.
This patch adds pnet table configuration support using the
generic netlink message interface referring to network and IB device
by their names. Commands exist to add, delete, and display pnet table
entries, and to flush or display the entire pnet table.

There are cross-checks to verify whether the ethernet interfaces
or infiniband devices really exist in the system. If either device
is not available, the pnet ID entry is not created.
Loss of network devices and IB devices is also monitored;
a pnet ID entry is removed when an associated network or
IB device is removed.

Signed-off-by: Thomas Richter <tmricht@linux.vnet.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-01-09 16:07:38 -05:00