Commit Graph

18 Commits

Author SHA1 Message Date
kbuild test robot e3da2ce04e power: supply: cpcap-charger: cpcap_charger_voltage_to_regval() can be static
Add 'static' keyword to internal function as reported by sparse
using the following configuration:

make ARCH=x86_64 allmodconfig
make C=1 CF='-fdiagnostic-prefix -D__CHECK_ENDIAN__'

Fixes: d4ee021c41 ("power: supply: cpcap-charger: Limit voltage to 4.2V for battery")
Signed-off-by: kbuild test robot <lkp@intel.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-10-21 10:43:41 +02:00
Tony Lindgren 5688ea0492 power: supply: cpcap-charger: Allow changing constant charge voltage
Let's allow reconfiguring the cpcap-charger max charge voltage and
default to 4.2V that should be safe for the known users.

This allows the users to use 4.35V for the extra capacity if really
needed at a cost of probably shorter battery life. We check the
constant charge voltage limit set by the battery.

Some pieces of the property setting code is based on an earlier patch
from Pavel Machek <pavel@ucw.cz> but limited to configuring the charge
voltage for now.

Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-10-20 20:26:23 +02:00
Tony Lindgren 50fc99f83f power: supply: cpcap-charger: Improve battery detection
We are currently using a wrong ADC range for the battery detection.
The ADC returns the battery temperature if connected.

Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-10-20 20:26:17 +02:00
Tony Lindgren d4ee021c41 power: supply: cpcap-charger: Limit voltage to 4.2V for battery
There have been some cases of droid4 battery bulging that seem to be
related to being left connected to the charger for several weeks.

It is suspected that the 4.35V charge voltage configured for the battery
is too much in the long run, so lets limit the charge voltage to 4.2V.
It could also be that the batteries are just getting old.

We don't really want to just change the charge voltage to 4.2V as Android
may have charged the battery to 4.35V as pointed out by Pavel Machek.

To add checks for battery voltage, the driver needs to understand the
voltage it's charging at, and also needs to better understand it's
charger state. Right now it only understands connect and disconnect,
while now we need to know also a connected state but not charging.

So let's add better charger state handling with help of chrgcurr2 interrupt
for detecting charge full and retry, and add a check for battery voltage
before we start charging. And then we finally can lower the charge voltage
to 4.2V.

Note that we've been using the same register values as the Android distros
on droid4, so it is suspected that the same problem also exists in Android.

Cc: Pavel Machek <pavel@ucw.cz>
Cc: Rob Herring <robh+dt@kernel.org>
Reported-by: Merlijn Wajer <merlijn@wizzup.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-10-20 19:10:39 +02:00
Tony Lindgren 7f7378618b power: supply: cpcap-charger: Enable vbus boost voltage
We are currently not enabling VBUS boost for cpcap when in host mode.
This means the VBUS is fed at the battery voltage level, which can cause
flakeyness enumerating devices.

Looks like the boost control for VBUS is CPCAP_BIT_VBUS_SWITCH that we
must enable in the charger for nice 4.92 V VBUS output. And looks like
we must not use the STBY pin enabling but must instead use manual VBUS
control in phy-cpcap-usb.

We want to do this in cpcap_charger_vbus_work() and also set a flag for
feeding_vbus to avoid races between USB detection and charger detection,
and disable charging if feeding_vbus is set.

Cc: Jacopo Mondi <jacopo@jmondi.org>
Cc: Kishon Vijay Abraham I <kishon@ti.com>
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Michael Scott <hashcode0f@gmail.com>
Cc: NeKit <nekit1000@gmail.com>
Cc: Pavel Machek <pavel@ucw.cz>
Cc: Sebastian Reichel <sre@kernel.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-09-02 23:08:07 +02:00
Thomas Gleixner 1802d0beec treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 174
Based on 1 normalized pattern(s):

  this program is free software you can redistribute it and or modify
  it under the terms of the gnu general public license version 2 as
  published by the free software foundation this program is
  distributed in the hope that it will be useful but without any
  warranty without even the implied warranty of merchantability or
  fitness for a particular purpose see the gnu general public license
  for more details

extracted by the scancode license scanner the SPDX license identifier

  GPL-2.0-only

has been chosen to replace the boilerplate/reference in 655 file(s).

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Allison Randal <allison@lohutok.net>
Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Reviewed-by: Richard Fontana <rfontana@redhat.com>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190527070034.575739538@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-05-30 11:26:41 -07:00
Tony Lindgren 7d90fcc14a power: supply: cpcap-charger: Fix pointless EPROBE_DEFER warnings
With loadable modules we may get the following during init:

could not initialize VBUS or ID IIO: -517

Let's not print any pointless error messages for deferred probe.

Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-04-15 22:54:06 +02:00
Pavel Machek fd10606f93 cpcap-charger: generate events for userspace
The driver doesn't generate uevents on charger connect/disconnect.
This leads to UPower not detecting when AC is on or off... and that is
bad.

Reported by Arthur D. on github (
https://github.com/maemo-leste/bugtracker/issues/206 ), thanks to
Merlijn Wajer for suggesting a fix.

Cc: stable@kernel.org
Signed-off-by: Pavel Machek <pavel@ucw.cz>
Acked-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-01-20 22:40:27 +01:00
Colin Ian King 80fca773bf power: supply: cpcap-charger: clean an indentation issue, remove tab
Trivial fix to clean up indentation issue, remove an extraneous tab

Signed-off-by: Colin Ian King <colin.king@canonical.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2018-12-05 19:02:11 +01:00
Pan Bian 838c8afa67 power: supply: cpcap-charger: fix incorrect return value check
Function platform_get_irq_byname() returns a negative error code on
failure, and a zero or positive number on success. However, in function
cpcap_usb_init_irq(), positive IRQ numbers are also taken as error
cases. Use "if (irq < 0)" instead of "if (!irq)" to validate the return
value of platform_get_irq_byname().

Signed-off-by: Pan Bian <bianpan2016@163.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
2017-11-13 11:56:12 +01:00
Tony Lindgren fc44313830 power: supply: cpcap-charger: Add missing power_supply_config
Otherwise cpcap-battery won't probe properly with the power-supplies
property configured but will fail with "Not all required supplies found,
defer probe".

Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
2017-06-15 10:16:59 +02:00
Tony Lindgren 70c9fc9a56 power: supply: cpcap-charger: Fix charger voltages based on ADC values
With the ADC driver working, we can now fix the voltage table based on
the values read from the ADC.

Note that unlike the ICHRG registers, the VCHRG register bits don't
match the MC13783UG.pdf.

Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sre@kernel.org>
2017-05-14 18:26:13 +02:00
Tony Lindgren 1e45330bd2 power: supply: cpcap-charger: Update charge current table and add comments
Turns out a similar battery charger hardware is documented for NXP MC13783
PMIC in "MC13783 Power Management and Audio Circuit Users's Guide" named
MC13783UG.pdf. Looks like the CPCAP charge current table matches that, so
let's start using the nominal values from it.

While at it, let's also add comments to some of the mystery CPCAP charger
registers based on the MC13783UG.pdf documentation.

Note that this patch does not contain any functional changes, the register
values being used stay the same.

Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sre@kernel.org>
2017-05-14 18:26:13 +02:00
Tony Lindgren 35f4f99ccb power: supply: cpcap-charger: Keep trickle charger bits disabled
Android does not seem to set the trickle charger bits, and these
seem to be only used by the bootloader when bringing up a
completely discharged battery. So let's keep the trickle charging
bits disabled and avoid misconfiguring the hardware.

Fixes: 0c9888e3c1 ("power: supply: cpcap-charger: Add minimal
CPCAP PMIC battery charger")
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
2017-05-04 17:52:00 +02:00
Tony Lindgren 6ffa8ace70 power: supply: cpcap-charger: Fix enable for 3.8V charge setting
Zero is a valid register value for for 3.8V charging.

Fixes: 0c9888e3c1 ("power: supply: cpcap-charger: Add minimal
CPCAP PMIC battery charger")
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
2017-05-04 17:51:52 +02:00
Tony Lindgren 3ae5f06681 power: supply: cpcap-charger: Fix charge voltage configuration
We have the charge voltage wrong, it should be 4.35V instead of 4.2V.
This will cause the battery to never get fully charged.

I noticed this when looking at the Andoid kernel battery and charger
status for a fully charged battery:

POWER_SUPPLY_VOLTAGE_NOW=4351000

Also the battery on droid 4 says "4.35, 1735/1785mAh (min/typ),
6.6/6.8 Wh (min/typ)". Presumably the 4.35 on the battery is the
charge voltage.

And finally, on Android the CPCAP CRM register is set to 0x03b5 where
the b is the charge voltage.

Let's fix the charge voltage define and update the charge configuration
to use the 4.35V setting.

Fixes: 0c9888e3c1 ("power: supply: cpcap-charger: Add minimal
CPCAP PMIC battery charger")
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
2017-05-04 17:51:44 +02:00
Tony Lindgren 4f700a5285 power: supply: cpcap-charger: Fix charger name
I noticed we have a different name from what Android is using.
Let's not break the /sys/class/power user space interface here
and use the same naming as Android has.

On Android we have the following for droid 4:

$ ls /sys/class/power_supply/
ac battery usb

So let's use the usb naming here for charger too.

Fixes: 0c9888e3c1 ("power: supply: cpcap-charger: Add minimal
CPCAP PMIC battery charger")
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
2017-05-04 17:51:32 +02:00
Tony Lindgren 0c9888e3c1 power: supply: cpcap-charger: Add minimal CPCAP PMIC battery charger
The custom CPCAP PMIC used on Motorola phones such as Droid 4 has a
USB battery charger. It can optionally also have a companion chip that
is used for wireless charging.

The charger on CPCAP also can feed VBUS for the USB host mode. This
can be handled by the existing kernel phy_companion interface.

Cc: devicetree@vger.kernel.org
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Sebastian Reichel <sre@kernel.org>
2017-04-14 01:41:34 +02:00