Make fan and pwm names in sysfs start with index 1 in accordance to
Documentation/hwmon/sysfs-interface conventions.
Current implementation starts with index 0, making tools such as
sensors(1) skip the first fan.
Signed-off-by: Stefan Schaeckeler <sschaeck@cisco.com>
Fixes: 2d7a548a3e ("drivers: hwmon: Support for ASPEED PWM/Fan tach")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Call of_node_put() on a node claimed with of_node_get() or by any other
means such as for_each_child_of_node().
Signed-off-by: Stefan Schaeckeler <sschaeck@cisco.com>
Fixes: 2d7a548a3e ("drivers: hwmon: Support for ASPEED PWM/Fan tach")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
When the controller fails to provide an RPM reading within the alloted
time; the driver returns -ETIMEDOUT and no file contents.
Signed-off-by: Patrick Venture <venture@google.com>
Fixes: 2d7a548a3e ("drivers: hwmon: Support for ASPEED PWM/Fan tach")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
The ASPEED AST2400/2500 PWM controller supports 8 PWM output ports.
The ASPEED AST2400/2500 Fan tach controller supports 16 tachometer
inputs.
The device driver matches on the device tree node. The configuration
values are read from the device tree and written to the respective
registers.
The driver provides a sysfs entries through which the user can
configure the duty-cycle value (ranging from 0 to 100 percent) and read
the fan tach rpm value.
Signed-off-by: Jaghathiswari Rankappagounder Natarajan <jaghu@google.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>