Commit Graph

567 Commits

Author SHA1 Message Date
Zhang Rui ad0f409051 int340x_thermal/processor_thermal_device: return failure when
there is no ACPI device object

processor_thermal_device driver needs ACPI support to work. Thus, the driver
probing should fail when there is no ACPI device object asscociated.

This fixes a NULL pointer dereference when the driver is loaded
with INT340X feature disabled in BIOS.

Reported-by: Chen Yu <yu.c.chen@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Tested-by: Chen Yu <yu.c.chen@intel.com>
2015-01-06 08:18:21 +08:00
Zhang Rui 48628e4015 ACPI/int340x_thermal: enumerate INT340X devices even if they're not in _ART/_TRT
For some INT340X thermal devices, even if they are not referred in
_TRT/_ART table, they still can be used by userspace for thermal control.
Thus change the code to enumerated all the INT340X devices,
no matter if they're referred in _TRT/_ART or not.

Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Tested-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
2015-01-06 08:17:06 +08:00
Zhang Rui 7429b1e0d0 Merge branches 'thermal-core', 'thermal-soc' and 'thermal-int340x' of .git into next 2014-12-24 10:38:30 +08:00
Srinivas Pandruvada f8061d383b Thermal/int340x/int3403: Free acpi notification handler
Remove acpi notification handler when zone is removed.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-24 10:37:44 +08:00
Srinivas Pandruvada cc3f71a415 Thermal/int340x/processor_thermal: Fix memory leak
Address memory leak for buffer allocated with ACPI_ALLOCATE_BUFFER.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-24 10:37:43 +08:00
Srinivas Pandruvada f01bc8f37e Thermal/int340x/int3403: Fix memory leak
Address memory leak for buffer allocated with ACPI_ALLOCATE_BUFFER.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-24 10:37:43 +08:00
Srinivas Pandruvada 47c93e6b3f thermal: int340x: Introduce processor reporting device
The Int340x thermal provides a processor thermal device, which
is used to control processor thermal states. These devices are
either reported as a PCI device or an ACPI device. This
device provides power limits, control states and optional
temperature.
This change implements minimal requirements to expose processor
power limits which can be used during thermal power limiting.
Power limits are exposed via an attribute group called
"power_limits" under the device. The exported attributes
are:
power_limit_0_max_uw
power_limit_1_max_uw
power_limit_0_min_uw
power_limit_1_min_uw
power_limit_0_tmin_us
power_limit_1_tmin_us
power_limit_0_tmax_us
power_limit_1_tmax_us
power_limit_0_step_uw
power_limit_1_step_uw

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-24 10:37:35 +08:00
Wolfram Sang 0716b0ff0a thermal: int340x_thermal: drop owner assignment from platform_drivers
This platform_driver does not need to set an owner, it will be populated by the
driver core.

Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-22 11:06:42 +08:00
Wolfram Sang 0733d1387e thermal: drop owner assignment from platform_drivers
This platform_driver does not need to set an owner, it will be populated by the
driver core.

Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
2014-12-22 11:05:59 +08:00
Zhang Rui 32c9edc4e3 Merge branch 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal into thermal-soc 2014-12-21 22:49:12 +08:00
Javi Merino fc4de356e0 thermal: cpu_cooling: document node in struct cpufreq_cooling_device
The node field of struct cpufreq_cooling_device was reintroduced in
2dcd851fe4 (thermal: cpu_cooling: Update always cpufreq policy with
thermal constraints) but without the documentation that it once had.
Add it back so that all the fields of struct cpufreq_cooling_device
are documented.

Cc: Yadwinder Singh Brar <yadi.brar@samsung.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-21 21:40:13 +08:00
Jacob Pan 59c56eb6db thermal/powerclamp: add ids for future xeon cpus
Enable Intel Powerclamp driver on Xeon cpu id 0x56, package C-state
is available on this CPU for idle injection.

Signed-off-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-21 21:36:41 +08:00
Ilkka Koskinen 7b09406390 Thermal/int340x: Handle properly the case when _trt or _art acpi entry is missing
If either of the entries was missing, the driver tried to free memory
using uninitialized pointer. In addition, it was dereferencing null
pointer.

Signed-off-by: Ilkka Koskinen <ilkka.koskinen@linux.intel.com>
Acked-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-21 21:27:25 +08:00
Linus Torvalds 4bb9374e0b Merge branch 'timers-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip
Pull NOHZ update from Thomas Gleixner:
 "Remove the call into the nohz idle code from the fake 'idle' thread in
  the powerclamp driver along with the export of those functions which
  was smuggeled in via the thermal tree.  People have tried to hack
  around it in the nohz core code, but it just violates all rightful
  assumptions of that code about the only valid calling context (i.e.
  the proper idle task).

  The powerclamp trainwreck will still work, it just wont get the
  benefit of long idle sleeps"

* 'timers-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip:
  tick/powerclamp: Remove tick_nohz_idle abuse
2014-12-19 13:29:20 -08:00
Thomas Gleixner a5fd9733a3 tick/powerclamp: Remove tick_nohz_idle abuse
commit 4dbd27711c "tick: export nohz tick idle symbols for module
use" was merged via the thermal tree without an explicit ack from the
relevant maintainers.

The exports are abused by the intel powerclamp driver which implements
a fake idle state from a sched FIFO task. This causes all kinds of
wreckage in the NOHZ core code which rightfully assumes that
tick_nohz_idle_enter/exit() are only called from the idle task itself.

Recent changes in the NOHZ core lead to a failure of the powerclamp
driver and now people try to hack completely broken and backwards
workarounds into the NOHZ core code. This is completely unacceptable
and just papers over the real problem. There are way more subtle
issues lurking around the corner.

The real solution is to fix the powerclamp driver by rewriting it with
a sane concept, but that's beyond the scope of this.

So the only solution for now is to remove the calls into the core NOHZ
code from the powerclamp trainwreck along with the exports. 

Fixes: d6d71ee4a1 "PM: Introduce Intel PowerClamp Driver"
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Cc: Preeti U Murthy <preeti@linux.vnet.ibm.com>
Cc: Viresh Kumar <viresh.kumar@linaro.org>
Cc: Frederic Weisbecker <fweisbec@gmail.com>
Cc: Fengguang Wu <fengguang.wu@intel.com>
Cc: Frederic Weisbecker <frederic@kernel.org>
Cc: Pan Jacob jun <jacob.jun.pan@intel.com>
Cc: LKP <lkp@01.org>
Cc: Peter Zijlstra <peterz@infradead.org>
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: stable@vger.kernel.org
Link: http://lkml.kernel.org/r/alpine.DEB.2.11.1412181110110.17382@nanos
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
2014-12-19 14:05:52 +01:00
Linus Torvalds 2efda9042d Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management update from Zhang Rui:
 "Summary:

   - of-thermal extension to allow drivers to register and use its
     functionality in a better way, without exploiting thermal core.
     From Lukasz Majewski.

   - Fix a bug in intel_soc_dts_thermal driver which calls a sleep
     function in interrupt handler.  From Maurice Petallo.

   - add a thermal UAPI header file for exporting the thermal generic
     netlink information to user-space.  From Florian Fainelli.

   - First round of refactoring in Exynos driver.  Bartlomiej and Lukasz
     are attempting to make it lean and easier to understand.

   - New thermal driver for Rockchip (rk3288), with support for DT
     thermal.  From Caesar Wang.

   - New thermal driver for Nvidia, Tegra124 SOCTHERM driver, with
     support for DT thermal.  From Mikko Perttunen.

   - New cooling device, based on common clock framework.  From Eduardo
     Valentin.

   - a couple of small fixes in thermal core framework.  From Srinivas
     Pandruvada, Javi Merino, Luis Henriques.

   - Dropping Armada A375-Z1 SoC thermal support as the chip is not in
     the market, armada folks decided to drop its support.

   - a couple of small fixes and cleanups in int340x thermal driver"

* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (58 commits)
  thermal: provide an UAPI header file
  Thermal/int340x: Clear the error value of the last acpi_bus_get_device() call
  thermal/powerclamp: add id for braswell cpu
  thermal: Intel SoC DTS: Don't do thermal zone update inside spin_lock
  Thermal: fix platform_no_drv_owner.cocci warnings
  Thermal/int340x: avoid unnecessary pointer casting
  thermal: int3403: Delete a check before thermal_zone_device_unregister()
  thermal/int3400: export uuids
  thermal: of: Extend current of-thermal.c code to allow setting emulated temp
  thermal: of: Extend of-thermal to export table of trip points
  thermal: of: Rename struct __thermal_trip to struct thermal_trip
  thermal: of: Extend of-thermal.c to provide check if trip point is valid
  thermal: of: Extend of-thermal.c to provide number of trip points
  thermal: Fix error path in thermal_init()
  thermal: lock the thermal zone when switching governors
  thermal: core: ignore invalid trip temperature
  thermal: armada: Remove support for A375-Z1 SoC
  thermal: rockchip: add driver for thermal
  dt-bindings: document Rockchip thermal
  thermal: exynos: remove exynos_tmu_data.h include
  ...
2014-12-17 10:16:27 -08:00
Dan Carpenter 2d2e95ea8f thermal: cpu_cooling: small memory leak on error
There was a left over return here so the error handling isn't run.
It leads to a small memory leak and a static checker warning.

	drivers/thermal/cpu_cooling.c:351 __cpufreq_cooling_register()
	info: ignoring unreachable code.

Fixes: f6859014c7 ("thermal: cpu_cooling: Store frequencies in descending order")
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-17 08:54:04 -04:00
Linus Torvalds e6b5be2be4 Driver core patches for 3.19-rc1
Here's the set of driver core patches for 3.19-rc1.
 
 They are dominated by the removal of the .owner field in platform
 drivers.  They touch a lot of files, but they are "simple" changes, just
 removing a line in a structure.
 
 Other than that, a few minor driver core and debugfs changes.  There are
 some ath9k patches coming in through this tree that have been acked by
 the wireless maintainers as they relied on the debugfs changes.
 
 Everything has been in linux-next for a while.
 
 Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
 -----BEGIN PGP SIGNATURE-----
 Version: GnuPG v2
 
 iEYEABECAAYFAlSOD20ACgkQMUfUDdst+ylLPACg2QrW1oHhdTMT9WI8jihlHVRM
 53kAoLeteByQ3iVwWurwwseRPiWa8+MI
 =OVRS
 -----END PGP SIGNATURE-----

Merge tag 'driver-core-3.19-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/driver-core

Pull driver core update from Greg KH:
 "Here's the set of driver core patches for 3.19-rc1.

  They are dominated by the removal of the .owner field in platform
  drivers.  They touch a lot of files, but they are "simple" changes,
  just removing a line in a structure.

  Other than that, a few minor driver core and debugfs changes.  There
  are some ath9k patches coming in through this tree that have been
  acked by the wireless maintainers as they relied on the debugfs
  changes.

  Everything has been in linux-next for a while"

* tag 'driver-core-3.19-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/driver-core: (324 commits)
  Revert "ath: ath9k: use debugfs_create_devm_seqfile() helper for seq_file entries"
  fs: debugfs: add forward declaration for struct device type
  firmware class: Deletion of an unnecessary check before the function call "vunmap"
  firmware loader: fix hung task warning dump
  devcoredump: provide a one-way disable function
  device: Add dev_<level>_once variants
  ath: ath9k: use debugfs_create_devm_seqfile() helper for seq_file entries
  ath: use seq_file api for ath9k debugfs files
  debugfs: add helper function to create device related seq_file
  drivers/base: cacheinfo: remove noisy error boot message
  Revert "core: platform: add warning if driver has no owner"
  drivers: base: support cpu cache information interface to userspace via sysfs
  drivers: base: add cpu_device_create to support per-cpu devices
  topology: replace custom attribute macros with standard DEVICE_ATTR*
  cpumask: factor out show_cpumap into separate helper function
  driver core: Fix unbalanced device reference in drivers_probe
  driver core: fix race with userland in device_add()
  sysfs/kernfs: make read requests on pre-alloc files use the buffer.
  sysfs/kernfs: allow attributes to request write buffer be pre-allocated.
  fs: sysfs: return EGBIG on write if offset is larger than file size
  ...
2014-12-14 16:10:09 -08:00
Zhang Rui 2707dbd09a Merge branches 'thermal-core-fix', 'thermal-soc' and 'thermal-int340x' into next 2014-12-13 12:25:19 +08:00
Eduardo Valentin cffafc3247 thermal: ti-soc-thermal: Do not print error message in the EPROBE_DEFER case
Avoid printing the error message in the EPROBE_DEFER case
where registering cpu cooling at ti-soc-thermal thermal driver.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-12 10:08:31 -04:00
Eduardo Valentin 38cbf0414c thermal: db8500: Do not print error message in the EPROBE_DEFER case
Avoid printing the error message in the EPROBE_DEFER case
where registering cpu cooling at db8500 thermal driver.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Grant Likely <grant.likely@linaro.org>
Cc: Rob Herring <robh+dt@kernel.org>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Cc: devicetree@vger.kernel.org
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-12 10:08:07 -04:00
Fabio Estevam 412aff9497 thermal: imx: Do not print error message in the EPROBE_DEFER case
During imx_thermal probe we have the following log:

[    1.514819] imx_thermal 2000000.aips-bus:tempmon: failed to register cpufreq cooling device: -517
[    1.515064] platform 2000000.aips-bus:tempmon: Driver imx_thermal requests probe deferral

Avoid printing the error message in the EPROBE_DEFER case.

Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-12 09:53:46 -04:00
Abhilash Kesavan fcbb1e02ee drivers: thermal: Remove ARCH_HAS_BANDGAP dependency for samsung
As samsung thermal support is enabled only for ARCH_EXYNOS, there is no
need to select ARCH_HAS_BANDGAP from the arch-specific code. Removing this
dependency will also allow the driver to be enabled on 64-bit SoCs.

Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Reviewed-by: Lukasz Majewski <l.majewski@samsung.com>
Acked-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Abhilash Kesavan <a.kesavan@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-10 11:06:18 -04:00
Ilkka Koskinen e413ad7cca Thermal/int340x: Clear the error value of the last acpi_bus_get_device() call
Previously the return value of the last acpi_bus_get_device() was
returned. However, since we only report those issues, it should be
cleared to continue as expected.

Signed-off-by: Ilkka Koskinen <ilkka.koskinen@linux.intel.com>
Acked-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
2014-12-09 14:05:05 +08:00
Zhang Rui c89d99546d Merge branch 'eduardo-soc-thermal' into thermal-soc 2014-12-09 11:38:34 +08:00
Jacob Pan 5a530ff0d8 thermal/powerclamp: add id for braswell cpu
Braswell also has package C-states which can be used for idle
injection. This patch adds Braswell CPU ID in intel powerclamp
driver.

Signed-off-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:38:17 +08:00
Maurice Petallo 05629296ee thermal: Intel SoC DTS: Don't do thermal zone update inside spin_lock
The driver calls spin_lock_irqsave during DTS interrupt. The interrupt
handle then calls thermal_zone_device_update which implicitly calls
a sleep function and produce the following bug:

BUG: sleeping function called from invalid context at kernel/locking/mutex.c:97
in_atomic(): 1, irqs_disabled(): 1, pid: 920, name: irq/86-soc_dts
CPU: 0 PID: 920 Comm: irq/86-soc_dts Tainted: G            E  3.17.0-rc2+ #1
Hardware name: Intel Corp. VALLEYVIEW B3 PLATFORM/NOTEBOOK, BIOS BYTICRB1.86C.0092.R31.1408290850 08/29/2014
 00000000 00000000 c25dbe74 c1818cfd f3cc488c c25dbe9c c1059305 c1b4063b
 00000001 00000001 00000398 f3cc488c f6817644 f6817644 f3ecc6c0 c25dbea8
 c18208f2 f6817400 c25dbebc c159b0bb c25dbedc f6817400 f32a2300 c25dbee8
Call Trace:
 [<c1818cfd>] dump_stack+0x48/0x60
 [<c1059305>] __might_sleep+0xec/0xf4
 [<c18208f2>] mutex_lock+0x1c/0x34
 [<c159b0bb>] thermal_zone_get_temp+0x34/0x59
 [<c159bde5>] thermal_zone_device_update+0x2d/0xcb
 [<f85da16a>] ? iosf_mbi_write+0x6c/0x74 [iosf_mbi]
 [<f7c7445d>] soc_irq_thread_fn+0x10c/0x163 [intel_soc_dts_thermal]
 [<c107b72b>] irq_thread_fn+0x18/0x2a
 [<c107bedb>] irq_thread+0x81/0x11f
 [<c107b713>] ? irq_finalize_oneshot+0x7c/0x7c
 [<c107bf79>] ? irq_thread+0x11f/0x11f
 [<c107be5a>] ? wake_threads_waitq+0x31/0x31
 [<c1054217>] kthread+0x87/0x8c
 [<c1821e41>] ret_from_kernel_thread+0x21/0x30
 [<c1054190>] ? __kthread_parkme+0x55/0x55

Signed-off-by: Maurice Petallo <mauricex.r.petallo@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Eduardo Valentin <edubezval@gmail.com>
CC: Kweh, Hock Leong <hock.leong.kweh@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:38:16 +08:00
Zhang Rui 9c1e4550b5 Merge branch 'linus' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal into eduardo-soc-thermal 2014-12-09 11:37:35 +08:00
Wu Fengguang 341203167f Thermal: fix platform_no_drv_owner.cocci warnings
drivers/thermal/int340x_thermal/int3403_thermal.c:468:3-8: No need to set .owner here. The core will do it.

 Remove .owner field if calls are used which set it automatically

Generated by: scripts/coccinelle/api/platform_no_drv_owner.cocci

Signed-off-by: Fengguang Wu <fengguang.wu@intel.com>
Acked-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:31:20 +08:00
Jacob Pan b81e5962af Thermal/int340x: avoid unnecessary pointer casting
Avoid pointer casting which may also lead to problems on big endian
64 bit systems.

Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:31:19 +08:00
Markus Elfring 931b9c86d9 thermal: int3403: Delete a check before thermal_zone_device_unregister()
The thermal_zone_device_unregister() function tests whether its argument
is NULL and then returns immediately. Thus the test around the call
is not needed.

This issue was detected by using the Coccinelle software.

Signed-off-by: Markus Elfring <elfring@users.sourceforge.net>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:31:18 +08:00
Srinivas Pandruvada 19ecaea268 thermal/int3400: export uuids
INT3400 currently supports only one policy, which can't be changed.
This change exports all available policies (uuids) to user space and
allow this to be changed.
It introduces an attribute group uuids in INT3400 platform driver.
There are two attributes exposed:
- available_uuids
- current_uuid

User space can set current_uuid via this interface to one of the
available uuids. The uuid change is communicated to firmware, only
when the current zone mode is changed to "enabled". So the ideal
sequence should be
- set INT3400 zone mode to "disabled"
- change current_uuid
- set INT3400 zone mode to "enabled"

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:31:17 +08:00
Lukasz Majewski 9a3031dc3e thermal:core:fix: Check return code of the ->get_max_state() callback
The return code from ->get_max_state() callback was not checked during
binding cooling device to thermal zone device.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 21:32:56 -04:00
Lukasz Majewski 184a4bf623 thermal: of: Extend current of-thermal.c code to allow setting emulated temp
Before this change it was only possible to set get_temp() and get_trend()
methods to be used in the common code handling passing parameters via
device tree to "cpu-thermal" CPU thermal zone device.

Now it is possible to also set emulated value of temperature for debug
purposes.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 21:10:00 -04:00
Lukasz Majewski ce8be77859 thermal: of: Extend of-thermal to export table of trip points
This patch extends the of-thermal.c to export trip points for a given
thermal zone.

Thermal drivers should use of_thermal_get_trip_points() method to get
pointer to table of thermal trip points.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 15:58:01 -04:00
Lukasz Majewski ad9914ac3b thermal: of: Rename struct __thermal_trip to struct thermal_trip
This patch changes name of struct __thermal_trip to thermal_trip and moves
declaration of the latter to ./include/linux/thermal.h for better visibility.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 15:53:55 -04:00
Lukasz Majewski a9bf2cc49d thermal: of: Extend of-thermal.c to provide check if trip point is valid
This patch extends the of-thermal.c to provide check if trip point is
valid.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 15:45:29 -04:00
Lukasz Majewski 08dab66ec8 thermal: of: Extend of-thermal.c to provide number of trip points
This patch extends the of-thermal.c to provide information about number of
available trip points.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 15:38:32 -04:00
Viresh Kumar 73904cbc1a thermal: cpu_cooling: update copyright tags
Adding my copyright information for two purposes:
- To get cc'd for future patches to review (Only if people read this header
  while sending mail)
- Have done enough changes to earn a place here?

Cc: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:12:37 -04:00
Viresh Kumar 4843c4a190 thermal: cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
get_property() was an over complicated beast with BUGs. It used to believe that
cpufreq table is present in ascending or descending order, which might not
always be true.

Previous patch has created another freq table in descending order for us and we
better use it now. With that get_property() simply goes away and another helper
get_level() comes in.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:11:54 -04:00
Viresh Kumar f6859014c7 thermal: cpu_cooling: Store frequencies in descending order
CPUFreq framework *doesn't* guarantee that frequencies present in cpufreq table
will be in ascending or descending order. But cpu_cooling somehow assumes that.

Probably because most of current users are creating this list from DT, which is
done with the help of OPP layer. And OPP layer creates the list in ascending
order of frequencies.

But cpu_cooling can be used for other platforms too, which don't have
frequencies arranged in any order.

This patch tries to fix this issue by creating another list of valid frequencies
in descending order. Care is also taken to throw warnings for duplicate entries.

Later patches would use it to simplify code.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:11:02 -04:00
Viresh Kumar b9f8b41603 thermal: cpu_cooling: Pass 'cpufreq_dev' to get_property()
We already know the value of 'cpufreq_dev->max_level' and so there is no need
calculating that once again. For this, we need to send 'cpufreq_dev' to
get_property().

Make all necessary changes for this change. Because cpufreq_cooling_get_level()
doesn't have access to 'cpufreq_dev', it is updated to iterate over the list of
cpufreq_cooling_devices to get cooling device for the cpu number passed to it.
This also makes it robust to return levels only for the CPU registered via a
cooling device. We don't have to support anything that isn't registered yet.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:10:08 -04:00
Viresh Kumar 2479bb6443 thermal: cpu_cooling: use cpufreq_dev_list instead of cpufreq_dev_count
As we already have a list of cpufreq_cooling_devices now, lets use it instead of
a local counter.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:09:15 -04:00
Viresh Kumar 97afa4aafb thermal: cpu_cooling: get_property() doesn't need to support GET_MAXL anymore
We don't use get_property() to find max levels anymore as it is done at boot
now. So, don't support GET_MAXL in get_property().

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:08:05 -04:00
Viresh Kumar dcc6c7fdef thermal: cpu_cooling: find max level during device registration
CPU frequency tables don't update after the driver is registered and so we don't
need to iterate over them to find total number of states every time
cpufreq_get_max_state() is called. Do it once at boot time.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:07:10 -04:00
Viresh Kumar 521a2e5831 thermal: cpu_cooling: remove unnecessary wrapper get_cpu_frequency()
get_cpu_frequency() isn't doing much by itself, just calling get_property(). And
so this wrapper isn't required at all. Get rid of it.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:05:53 -04:00
Viresh Kumar 5194fe4699 thermal: cpu_cooling: Merge cpufreq_apply_cooling() into cpufreq_set_cur_state()
cpufreq_apply_cooling() has a single caller, cpufreq_set_cur_state() and
cpufreq_set_cur_state() is an unnecessary wrapper over cpufreq_apply_cooling().

Get rid of it by merging both routines.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:04:56 -04:00
Viresh Kumar 7adb635b3c thermal: cpu_cooling: initialize 'cpufreq_val' on registration
There is no point checking for validity of 'cpufreq_val' from
cpufreq_thermal_notifier() every time the routine is called. Its guaranteed to
be 0 on the first call but will be valid otherwise.

Lets update it once while the device registers.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:09:52 -04:00
Viresh Kumar 730abe064b thermal: cpu_cooling: do error handling at the bottom in __cpufreq_cooling_register()
This makes life easy and bug free. And is scalable for future resource
allocations.

Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:57 -04:00
Viresh Kumar c9ca319f05 thermal: cpu_cooling: Don't check is_cpufreq_valid()
Because get_cpu_frequency() has returned a valid frequency, it means that the
cpufreq policy is surely valid and so no point checking that again with
is_cpufreq_valid(). Get rid of the routine as well as there are no more users.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:57 -04:00