Add support for an optional regulator which, if found into device-tree,
will power on device at probing time.
The regulator is declared into ms5611 DTS entry as a "vdd-supply" property.
Signed-off-by: Gregor Boirie <gregor.boirie@parrot.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Use name of probed device instead of driver's one when registering device.
Signed-off-by: Gregor Boirie <gregor.boirie@parrot.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Computation of sens2 was wrong and is fixed by this patch, sens2 should be:
2 * (t - 2000)^2
See page 8 of ms5607 datasheet here:
http://www.meas-spec.com/product/pressure/MS5607-02BA03.aspx
Signed-off-by: Gregor Boirie <gregor.boirie@parrot.com>
Acked-by: Lucas De Marchi <lucas.demarchi@intel.com>
Acked-by: Peter Meerwald-Stadler <pmeerw@pmeerw.net>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This will be used together with an external trigger (e.g hrtimer
based software trigger).
Signed-off-by: Daniel Baluta <daniel.baluta@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This allows data exported via buffer interface to be converted
to standard units in userspace.
Signed-off-by: Daniel Baluta <daniel.baluta@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
MS5607 is temperature and pressure sensor which hardware is similar to MS5611.
Both sensors share command protocol and support both I2C and SPI serial
protocols. They only differ in compensation algorithms.
Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
IIO_CHAN_INFO_SCALE is useful whenever conversion to standard units is done
in userspace. In this case conversion is handled by driver so this bit
is unnecessary.
Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add support for Measurement Specialities MS5611 pressure
and temperature sensor.
Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>