If I/O queue connect times out, we might have freed the queue socket
already, so check for that on the error path in nvme_tcp_start_queue.
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
usually nvme_ prefix is for core functions.
While we're cleaning up, remove redundant empty lines
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Minwoo Im <minwoo.im@samsung.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
If we timeout the admin startup sequence we might not yet have
an I/O tagset allocated which causes the teardown sequence to crash.
Make nvme_tcp_teardown_io_queues safe by not iterating inflight tags
if the tagset wasn't allocated.
Fixes: 39d5775746 ("nvme-tcp: fix timeout handler")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_tcp_end_request just takes the status value and the converts
it to little endian as well as shifting for the phase bit.
Fixes: 43ce38a6d823 ("nvme-tcp: support C2HData with SUCCESS flag")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
A C2HData PDU with the SUCCESS flag set indicates that the I/O was
completed by the controller successfully and means that a subsequent
completion response capsule PDU will be ommitted.
If we see this flag, fisrt we check that LAST_PDU flag is set as well,
and then we complete the request when the data transfer (and data digest
verification if its on) is done.
While we're at it, reuse a bit of code with nvme_fail_request.
Reported-by: Steve Blightman <steve.blightman@oracle.com>
Suggested-by: Oliver Smith-Denny <osmithde@cisco.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Oliver Smith-Denny <osmithde@cisco.com>
Tested-by: Oliver Smith-Denny <osmithde@cisco.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
It is used now just to flush error recovery and reconnect work items in
the RDMA and TCP transports, which can simply be moved to the
corresponding teardown routines.
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Currently, we have several problems with the timeout
handler:
1. If we timeout on the controller establishment flow, we will hang
because we don't execute the error recovery (and we shouldn't because
the create_ctrl flow needs to fail and cleanup on its own)
2. We might also hang if we get a disconnet on a queue while the
controller is already deleting. This racy flow can cause the controller
disable/shutdown admin command to hang.
We cannot complete a timed out request from the timeout handler without
mutual exclusion from the teardown flow (e.g. nvme_rdma_error_recovery_work).
So we serialize it in the timeout handler and teardown io and admin
queues to guarantee that no one races with us from completing the
request.
Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
We should never touch the opal device from the transport driver.
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Preparation for polling support for fabrics. Polling support
means that our completion queues are not generating any interrupts
which means we need to poll for the nvmf io queue connect as well.
Reviewed by Steve Wise <swise@opengridcomputing.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is a spelling mistake in a dev_info message, fix it.
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Allow NVMF_OPT_NR_WRITE_QUEUES to describe additional write queues. In
addition, implement .map_queues that will apply 2 queue maps for read
and write queue sets.
Note that with the separate queue map, HCTX_TYPE_READ will always use
nr_io_queues and HCTX_TYPE_DEFAULT will use nr_write_queues.
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This patch implements the NVMe over TCP host driver. It can be used to
connect to remote NVMe over Fabrics subsystems over good old TCP/IP.
The driver implements the TP 8000 of how nvme over fabrics capsules and
data are encapsulated in nvme-tcp pdus and exchaged on top of a TCP byte
stream. nvme-tcp header and data digest are supported as well.
To connect to all NVMe over Fabrics controllers reachable on a given taget
port over TCP use the following command:
nvme connect-all -t tcp -a $IPADDR
This requires the latest version of nvme-cli with TCP support.
Signed-off-by: Sagi Grimberg <sagi@lightbitslabs.com>
Signed-off-by: Roy Shterman <roys@lightbitslabs.com>
Signed-off-by: Solganik Alexander <sashas@lightbitslabs.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>