It is possible for one HDMI connector to have multiple CEC adapters. The
typical real-world scenario is that where one adapter is used when the
device is in standby, and one that's better/smarter when the device is
powered up.
The cec-notifier changes were made with that in mind, but I missed that in
order to support this you need to tell cec_notifier_cec_adap_unregister()
which adapter you are unregistering from the notifier.
Add this additional argument. It is currently unused, but once all drivers
use this, the CEC core will be adapted for these use-cases.
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Reviewed-by: Ville Syrjälä <ville.syrjala@linux.intel.com>
Acked-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Link: https://patchwork.freedesktop.org/patch/msgid/e9fc8740-6be6-43a7-beee-ce2d7b54936e@xs4all.nl
Use cec_notifier_cec_adap_(un)register instead of
cec_notifier_get, cec_notifier_put and cec_register_cec_notifier.
Also enable the CEC_CAP_CONNECTOR_INFO capability.
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Cc: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Add SPDX license identifiers to all Make/Kconfig files which:
- Have no license information of any form
These files fall under the project license, GPL v2 only. The resulting SPDX
license identifier is:
GPL-2.0-only
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
The STI CEC driver increased the HDMI device refcount when
it shouldn't. Use the new helper function to ensure that that
doesn't happen and to simplify the driver code.
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Acked-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Use the new CEC_CAP_DEFAULTS define in this driver.
This also adds the CEC_CAP_RC capability which was missing here
(and this is also the reason for this new define, to avoid missing
such capabilities).
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Acked-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Use the helper function cec_transmit_attempt_done instead of
cec_transmit_done to simplify the code.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Acked-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Minor fixes in comments
Signed-off-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Hardware could support up to 16 logical addresses which is more
than needed by CEC specifications.
Let use CEC_MAX_LOG_ADDRS instead of limited it on one.
stih_cec_adap_log_addr() function was alredy written to support
multiple addresses requests.
Signed-off-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
By using the CEC notifier framework there is no longer any reason
to manually set the physical address. This was the one blocking
issue that prevented this driver from going out of staging, so do
this move as well.
Signed-off-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>