MCDI supports requests up to 252 bytes long, which is only enough to
pass 63 RX queue IDs to MC_CMD_FLUSH_RX_QUEUES. However a VF may have
up to 64 RX queues, and if we try to flush them all we will generate
an over-length request and BUG() in efx_mcdi_copyin(). Currently
all VF drivers limit themselves to 32 RX queues, so reducing the
limit to 63 does no harm.
Also add a BUILD_BUG_ON in efx_mcdi_flush_rxqs() so we remember to
deal with the same problem there if EFX_MAX_CHANNELS is increased.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
On big-endian systems the MTD partition names currently have mangled
subtype numbers and are not recognised by the firmware update tool
(sfupdate).
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
Add PTP IEEE-1588 support and make accesible via the PHC subsystem.
This work is based on prior code by Andrew Jackson
Signed-off-by: Stuart Hodgson <smhodgson@solarflare.com>
[bwh:
- Add byte order conversion in efx_ptp_send_times()
- Simplify conversion of PPS event times
- Add the built-in vs module check to CONFIG_SFC_PTP dependencies]
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
For NIC/System time synchonisation efx_mcdi_rpc needs to be split in
efx_mcdi_rpc_start and efx_mcdi_rpc_finish operations.
Signed-off-by: Stuart Hodgson <smhodgson@solarflare.com>
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
Fix CID 113952 in Coverity report on Linux.
This is the one instance where we don't, and shouldn't, check the
return code from efx_mcdi_rpc(). It wasn't immediately obvious to me
why we didn't, so I think an explanation is in order.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
On the SFC9000 family, each port has 1024 Virtual Interfaces (VIs),
each with an RX queue, a TX queue, an event queue and a mailbox
register. These may be assigned to up to 127 SR-IOV virtual functions
per port, with up to 64 VIs per VF.
We allocate an extra channel (IRQ and event queue only) to receive
requests from VF drivers.
There is a per-port limit of 4 concurrent RX queue flushes, and queue
flushes may be initiated by the MC in response to a Function Level
Reset (FLR) of a VF. Therefore, when SR-IOV is in use, we submit all
flush requests via the MC.
The RSS indirection table is shared with VFs, so the number of RX
queues used in the PF is limited to the number of VIs per VF.
This is almost entirely the work of Steve Hodgson, formerly
shodgson@solarflare.com.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
The SFC9000-family controllers have firmware to manage all board
peripherals including temperature, heat sink continuity and voltage
sensors. The firmware reports sensor alarms, which we log, and
will shut down the board if necessary.
Some users may want to monitor their boards more closely, so add an
hwmon driver that exposes all sensors reported by the firmware. Move
efx_mcdi_sensor_event() into the new file so it can share the array of
sensor labels with the hwmon driver.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
When the MC reboots, either as part of a firmware upgrade or due to a
bug, it attempts to complete (with an error) any requests that were
outstanding before the reboot. Since there is an inherent race
condition in checking this, it will also write to a status word in
shared memory.
If we look at each of these separately, we may detect each reboot
twice, resulting in a spurious command failure after a firmware
upgrade or frustrating recovery from a firmware bug. Instead, if a
request completion indicates a reboot, we must poll and clear the
status word.
This bug was previously masked by use of an incorrect address for the
status word. Fix that, using the definition now included in
mcdi_pcol.h.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
Moves the Solarflare drivers into drivers/net/ethernet/sfc/ and
make the necessary Kconfig and Makefile changes.
CC: Steve Hodgson <shodgson@solarflare.com>
CC: Ben Hutchings <bhutchings@solarflare.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>