If a load or store is the last instruction in a zero-overhead-loop, and
it's misaligned, the loop would execute only once.
This fixes that problem.
Signed-off-by: Mischa Jonker <mjonker@synopsys.com>
Signed-off-by: Vineet Gupta <vgupta@synopsys.com>
With ECR now part of pt_regs
* No need to propagate from lowest asm handlers as arg
* No need to save it in tsk->thread.cause_code
* Avoid bit chopping to access the bit-fields
More code consolidation, cleanup
Signed-off-by: Vineet Gupta <vgupta@synopsys.com>
ARC700 doesn't natively support unaligned access, but can be emulated
-Unaligned Access Exception
-Disassembly at the Fault address to find the exact insn (long/short)
Also per Arnd's comment, we runtime control it using 2 sysctl knobs:
* SYSCTL_ARCH_UNALIGN_ALLOW: Runtime enable/disble
* SYSCTL_ARCH_UNALIGN_NO_WARN: Warn on each emulation attempt
Originally contributed by Tim Yao <tim.yao@amlogic.com>
Signed-off-by: Vineet Gupta <vgupta@synopsys.com>
Cc: Tim Yao <tim.yao@amlogic.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>