Reset lines with indices smaller than 8 are currently considered invalid
by the rt2880-reset reset controller.
The MT7621 SoC uses a number of these low reset lines. The DTS defines
reset lines "hsdma", "fe", and "mcm" with respective values 5, 6, and 2.
As a result of the above restriction, these resets cannot be asserted or
de-asserted by the reset controller. In cases where the bootloader does
not de-assert these lines, this results in e.g. the MT7621's internal
switch staying in reset.
Change the reset controller to only ignore the system reset, so all
reset lines with index greater than 0 are considered valid.
Signed-off-by: Sander Vanheule <sander@svanheule.net>
Acked-by: John Crispin <john@phrozen.org>
Signed-off-by: Thomas Bogendoerfer <tsbogend@alpha.franken.de>
Based on 2 normalized pattern(s):
this program is free software you can redistribute it and or modify
it under the terms of the gnu general public license version 2 as
published by the free software foundation
this program is free software you can redistribute it and or modify
it under the terms of the gnu general public license version 2 as
published by the free software foundation #
extracted by the scancode license scanner the SPDX license identifier
GPL-2.0-only
has been chosen to replace the boilerplate/reference in 4122 file(s).
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Enrico Weigelt <info@metux.net>
Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Reviewed-by: Allison Randal <allison@lohutok.net>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190604081206.933168790@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
ralink_halt() does nothing that machine_halt() doesn't already do, so it
adds no value.
It actually causes incorrect behaviour due to the "unreachable()" at the
end. This tells the compiler that the end of the function will never be
reached, which isn't true. The compiler responds by not adding a
'return' instruction, so control simply moves on to whatever bytes come
afterwards in memory. In my tested, that was the ralink_restart()
function. This means that an attempt to 'halt' the machine would
actually cause a reboot.
So remove ralink_halt() so that a 'halt' really does halt.
Fixes: c06e836ada ("MIPS: ralink: adds reset code")
Signed-off-by: NeilBrown <neil@brown.name>
Cc: John Crispin <john@phrozen.org>
Cc: Ralf Baechle <ralf@linux-mips.org>
Cc: linux-mips@linux-mips.org
Cc: <stable@vger.kernel.org> # 3.9+
Patchwork: https://patchwork.linux-mips.org/patch/18851/
Signed-off-by: James Hogan <jhogan@kernel.org>
Resetting these SoCs requires no real magic. The code is straight forward.
Signed-off-by: John Crispin <blogic@openwrt.org>
Signed-off-by: Gabor Juhos <juhosg@openwrt.org>
Patchwork: http://patchwork.linux-mips.org/patch/4891/