Commit Graph

3 Commits

Author SHA1 Message Date
Marek Vasut f1deaee0c3 can: ifi: Fix TX DLC configuration
The TX DLC, the transmission length information, was not written
into the transmit configuration register. When using the CAN core
with different CAN controller, the receiving CAN controller will
receive only the ID part of the CAN frame, but no data at all.

This patch adds the TX DLC into the register to fix this issue.

Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Marc Kleine-Budde <mkl@pengutronix.de>
Cc: Mark Rutland <mark.rutland@arm.com>
Cc: Oliver Hartkopp <socketcan@hartkopp.net>
Cc: Wolfgang Grandegger <wg@grandegger.com>
Reviewed-by: Oliver Hartkopp <socketcan@hartkopp.net>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
2016-03-10 10:19:09 +01:00
Marek Vasut 99312c377f can: ifi: Fix clock generator configuration
The clock generation does not match reality when using the CAN IP
core outside of the FPGA design. This patch fixes the computation
of values which are programmed into the clock generator registers.

First, there are some off-by-one errors which manifest themselves
only when communicating with different controller, so those are
fixed.

Second, the bits in the clock generator registers have different
meaning depending on whether the core is in ISO CANFD mode or any
of the other modes (BOSCH CANFD or CAN2.0). Detect the ISO CANFD
mode and fix handling of this special case of clock configuration.

Finally, the CAN clock speed is in CANCLOCK register, not SYSCLOCK
register, so fix this as well.

Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Marc Kleine-Budde <mkl@pengutronix.de>
Cc: Mark Rutland <mark.rutland@arm.com>
Cc: Oliver Hartkopp <socketcan@hartkopp.net>
Cc: Wolfgang Grandegger <wg@grandegger.com>
Reviewed-by: Oliver Hartkopp <socketcan@hartkopp.net>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
2016-03-10 10:19:09 +01:00
Marek Vasut 0c4d9c94a1 can: ifi: Add IFI CANFD IP support
The patch adds support for IFI CAN/FD controller [1]. This driver
currently supports sending and receiving both standard CAN and new
CAN/FD frames. Both ISO and BOSCH variant of CAN/FD is supported.

[1] http://www.ifi-pld.de/IP/CANFD/canfd.html

Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Marc Kleine-Budde <mkl@pengutronix.de>
Cc: Mark Rutland <mark.rutland@arm.com>
Cc: Oliver Hartkopp <socketcan@hartkopp.net>
Cc: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
2016-02-20 14:56:15 +01:00