Fix W=1 compile warnings (invalid kerneldoc):
drivers/power/supply/cpcap-battery.c:292: warning: Function parameter or member 'ccd' not described in 'cpcap_battery_read_accumulated'
drivers/power/supply/cpcap-battery.c:292: warning: Excess function parameter 'regs' description in 'cpcap_battery_read_accumulated'
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This patch adds support for the coulomb counter calibration on init. We do
this by polling for now, and only add partial calibration done interrupt
support.
Then later on when we know for sure we have the calibration done interrupt
available in the device tree, we can switch to using the calibration done
interrupt.
Cc: Merlijn Wajer <merlijn@wizzup.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We can simplify code in the later patches by reading and saving the
integrator register CCI. Let's also fix a comment typo for register range
naming while at it.
Cc: Merlijn Wajer <merlijn@wizzup.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We can use sign_extend32() here to simplify things. And let's fix the
comment for CCM register, that contains the calibration offset.
Cc: Merlijn Wajer <merlijn@wizzup.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We can simplify cpcap_battery_cc_raw_div() with div_s64.
Cc: Merlijn Wajer <merlijn@wizzup.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We can simplify cpcap_battery_cc_raw_div() a bit by moving the units per
lsb to ddata.
Cc: Merlijn Wajer <merlijn@wizzup.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
With cpcap-charger now using 4.2V instead of 4.35V, we never reach
POWER_SUPPLY_CAPACITY_LEVEL_FULL unless we handle the lowered charge
voltage.
Let's do this by implementing POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
and assume anything at that level or higher is a full battery.
Let's also make it configurable for users who may still want to
reconfigure it, and notify the charger if supported by the charger.
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We can get the low voltage interrupt trigger sometimes way too early,
maybe because of CPU load spikes. This causes orderly_poweroff() be
called too easily.
Let's check the voltage before orderly_poweroff in case it was not
yet a permanent condition. We will be getting more interrupts anyways
if the condition persists.
Let's also show the measured voltages for low battery and battery
empty warnings since we have them.
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
With loadable modules we may get the following during init:
could not initialize VBUS or ID IIO: -517
Let's not print any pointless error messages for deferred probe.
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We should not use measured current value for average since we have proper
coulomb counter values available. Using measured current value should
be only used when the value is queried at a higher rate than the 250 ms
rate the coulomb counter is configured to run at.
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The coulomb counter calibration is not CCO, it's CCM. And the CCM is
nine bits wide signed register, so let's use sign_extend32() for it.
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The accumulator sample register is signed 32-bits wide register on
droid 4. And only the earlier version of cpcap has a signed 24-bits
wide register. We're currently passing it around as unsigned, so
let's fix that and use sign_extend32() for the earlier revision.
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We need to check current instead of the charge counter to see if
a charger is connected. The charge counter shows the cumulated value
instead of the current charge current and can be negative or positive.
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
If called fast enough so samples do not increment, we can get
division by zero in kernel:
__div0
cpcap_battery_cc_raw_div
cpcap_battery_get_property
power_supply_get_property.part.1
power_supply_get_property
power_supply_show_property
power_supply_uevent
Fixes: 874b2adbed ("power: supply: cpcap-battery: Add a battery driver")
Signed-off-by: Tony Lindgren <tony@atomide.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Don't populate the array cpcap_battery_irqs on the stack but instead
make it static. Makes the object code smaller by 99 bytes:
Before:
text data bss dec hex filename
13673 2448 0 16121 3ef9 cpcap-battery.o
After:
text data bss dec hex filename
13510 2512 0 16022 3e96 cpcap-battery.o
(gcc version 8.2.0 x86_64)
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The platform_get_irq_byname() function returns -1 if an error occurs.
zero or positive number on success. platform_get_irq_byname() error
checking for zero is not correct.
Signed-off-by: Arvind Yadav <arvind.yadav.cs@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
On the CPCAP PMIC we can use the ADCs for monitoring the battery,
and there is also a coulomb counter. So let's add basic support for
the battery driver.
I did not add any capacity prediction as that should probably be
done in the user space. Or at least user space should tell the kernel
some battery statistics and then the kernel driver could display the
capacity based on that.
Cc: devicetree@vger.kernel.org
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Cc: Rob Herring <robh@kernel.org>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>